MAYFIELD® R6367ARecalls & reported problems
Integra Lifesciences Corporation · Integra® 12mm Distraction Screw · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780025375), received between Apr 18, 2023 and Apr 18, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fracture1
- Material Twisted/Bent1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 18, 2023Fracture; Material Twisted/Bent; Fracture; Material Twisted/Bent
A FACILITY REPORTED THAT DURING SPINAL SURGERY, THE RUGGLES DISTRACTION SCREW - STERILE - 12 MM (R6367A) FRACTURED INSIDE OF THE PATIENT. REPORTEDLY, THREE (3) SCREWS WERE USED, TWO (2) BENT DURING USE AND ONE FAILED, COMPLETELY FRACTURING OFF INSIDE THE PATIENT¿S BONE. THE THE DISTRACTION SCREW FRAGMENT REMAINED IN THE PATIENT AND WAS UNABLE TO BE REMOVED. FOLLOWING THE EVENT, THE SURGEON PROCEEDED WITH THE SURGERY AND LEFT THE BROKEN PIECE IN THE VERTEBRAE. THERE WAS A DELAY OF AT LEAST 30 MINUTES AND PROLONGED EXPOSURE TO ANESTHESIA DUE TO THE DELAY IN TRYING TO GET THE BROKEN PIECE OUT AS WELL AS MULTIPLE PINS HAVING TO BE OPENED DUE TO THE BENDING. IT WAS REPORTED THAT THERE WAS NO COMPLICATIONS TO THE PATIENT POST-PROCEDURE.
Patient problems: Foreign Body In Patient
MAUDE report 16765132 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page