Integra® Jarit® 280405Recalls & reported problems
Integra Lifesciences Production Corporation · Integra® Jarit® Cushing Pituitary Rongeur, 7", Straight, 2X10mm Bite · Class 1
All models of Integra Jarit (57)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10381780385783), received between May 7, 2023 and Mar 21, 2025 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Difficult to Open or Close1
Patient problems
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMar 21, 2025Break; Break
THE FOLLOWING WAS REPORTED VIA MEDWATCH REPORT# MW5165904: "A 2MM PITUITARY RONGEUR BROKE WHILE IN USE, WORKING END TIP BROKE OFF INTO DISC SPACE. USING X-RAY TO IDENTIFY THE LOCATION, REMOVAL WAS ATTEMPTED. PIECE WAS UNABLE TO BE REMOVED." IT WAS SUBSEQUENTLY REPORTED THAT THERE WAS A DELAY IN SURGERY GREATER THAN 15 MINUTES. THE SURGERY WAS "COMPLETED WITH THE ADDITION OF ATTEMPTED REMOVAL UTILIZING X-RAY WHICH WAS UNSUCCESSFUL". IT WAS REPORTED THAT THE PATIENT'S CONDITION WAS STABLE FOLLOWING THE EVENT.
Patient problems: Foreign Body In Patient
MAUDE report 21670878 ↗MalfunctionMay 7, 2023Difficult to Open or Close; Difficult to Open or Close
A FACILITY REPORTED THAT DURING SURGERY, THE CUSHING RONGUER 7 2X10MM STR (280405) WAS NOT BITING/CLOSING PROPERLY; THE UPPER AND LOWER JAW WERE NOT TOUCHING OR CUTTING PROPERLY. NO PATIENT INJURY OCCURRED; HOWEVER, THERE WAS AN ESTIMATED 30-MINUTE INCREASE IN SURGERY TIME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883840 ↗
FDA clearance and classification
The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Integra® Jarit® 280405
Has the Integra® Jarit® 280405 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10381780385783), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Integra® Jarit® 280405?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 7, 2023 and Mar 21, 2025. In those reports, the most common specific device problems are “Break” (1) and “Difficult to Open or Close” (1); the most common patient problem is “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Integra® Jarit® 280405?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Integra® Jarit® 280405 FDA approved?
Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Integra Lifesciences Production Corporation.
Who makes the Integra® Jarit® 280405, and is it still sold?
The FDA's device database lists Integra Lifesciences Production Corporation as the company responsible for it (brand Integra® Jarit®, model 280405). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other RONGEUR devices
- SPOTLIGHT 292904201Depuy Spine, LLC · RONGEUR6 reports
- Symmetry RapidClean® 58-3200J-BDAspen Surgical Products, Inc. · Rongeur5 reports
- SPOTLIGHT 292904202Medos International Sàrl · RONGEUR5 reports
- NA 03.605.001Synthes GmbH · RONGEUR4 reports
- Symmetry Rapidclean® 58-3200-BDAspen Surgical Products, Inc. · Rongeur3 reports
- AESCULAP FF805RAesculap AG · RONGEUR3 reports
- Medicon 57.28.33Medicon eG. Chirurgiemechaniker-Genossenschaft · RONGEUR3 reports
- SPOTLIGHT 292902240Depuy Spine, LLC · RONGEUR3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page