SELF CENTERING 1035-53-000Recalls & reported problems

Depuy Orthopaedics, Inc. · SELF CENTERING BI-POLAR HEAD 28mm ID 53mm OD · Class 2 · Implant

All models of SELF CENTERING (29)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This DePuy self-centering bipolar hip head is the metal ball component used in partial hip replacement surgery. The 27 reports mostly describe hip infections that led to further surgery to wash out or swap out the implant, along with hip dislocation, pain after falls, and one case where the implant was found unstable. Reports mention 24 injuries and no deaths. There are no recalls naming this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
26
Deaths reported
0
Injuries reported
23
Recalls naming it
0

Summary

The FDA's MAUDE database contains 26 adverse event reports that list this exact device (DI 10603295003434), received between Aug 18, 2017 and Apr 30, 2026 — classified as 23 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem14
  • Device Dislodged or Dislocated5
  • Insufficient Device Problem Information5
  • Appropriate Device Problem Term/Code Not Available1
  • Device Expiration Issue1
  • Expiration Date Error1

Patient problems

  • Unspecified Infection11
  • Joint Dislocation4
  • Fall3
  • No Code Available3
  • Not Applicable3
  • Pain3
  • Damage to Ligament(s)2
  • Insufficient Information2

Recent adverse event reports

The 25 most recent of 26 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 30, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT DEVELOPED A HIP INFECTION. SURGEON WASHED THE HIP OUT AND REPLACED THE HEAD BALL COMPONENTS OF THE HEMI HIP. INFECTION WAS PRESENT. DOI: UNKNOWN. DOR: ON (B)(6) 2026. AFFECTED SIDE: LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 25052533 ↗
  • InjuryJan 8, 2026Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED FOR IRRIGATION AND DEBRIDEMENT WITH HEAD EXCHANGE DUE TO INFECTION. DOI: (B)(6) 2025. DOR: (B)(6) 2025. AFFECTED SIDE: LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 24009720 ↗
  • InjuryDec 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT FELL. A LARGE HEMOTOMA WAS REMOVED. HEAD AND CUP WERE SWAPPED. AFFECTED SIDE: RIGHT.

    Patient problems: Fall; Hematoma

    MAUDE report 23703739 ↗
  • InjuryJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED DUE TO UNSTABLE IMPLANT. DOI: UNKNOWN. DOR: (B)(6) 2024 . AFFECTED SIDE: UNKNOWN.

    Patient problems: Joint Laxity

    MAUDE report 21142585 ↗
  • InjuryOct 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT HAD AN INFECTION. THEY NEEDED A WASH OUT AND A BIPOLAR EXCHANGE. DOI: (B)(6) 2024, DOR: (B)(6) 2024 , AFFECTED SIDE: LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 20362985 ↗
  • InjuryJul 1, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED REVISION WAS COMPLETED DUE TO WORN ACETABULAR CARTILAGE. PATIENT WAS CONVERTED TO A TOTAL HIP. DOI: ON (B)(6) 2023, DOR: ON (B)(6) 2024, AFFECTED SIDE: RIGHT HIP.

    Patient problems: Damage to Ligament(s)

    MAUDE report 19647412 ↗
  • InjuryFeb 6, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PHYSICIAN NOTED DRAINAGE AT THE INCISION SITE, SO DECIDED TO PERFORM AN I&D AND SWITCH OUT THE BIPOLAR AND 28 HEAD. DOI: (B)(6) 2024. DOR: (B)(6) 2024. AFFECTED SIDE: LEFT HIP.

    Patient problems: Fluid Discharge

    MAUDE report 18650564 ↗
  • InjuryMar 28, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT PRESENTED A FEW DAYS AGO WITH A POSSIBLE JOINT INFECTION, SURGEON ELECTED TO WASH OUT AND CHANGE THE HEAD AND LINER. SURGICAL DELAY WAS UNKNOWN. DOI: (B)(6) 2023. DOR: (B)(6) 2023. AFFECTED SIDE: LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 16626596 ↗
  • MalfunctionJan 10, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT SHELLS WILL NOT STAY ON HEAD.

    Patient problems: Insufficient Information

    MAUDE report 16130676 ↗
  • InjuryOct 14, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT HAD A HEMIARTHROPLASTY ON (B)(6) 2021. THE SURGEON STATED THAT HE FELL A FEW DAYS AFTER AND DISLOCATED, THE PATIENT HAS PARKINSON¿S. THE SURGEON ELECTED TO REDUCE AND CHANGE THE BIPOLAR HEAD ON (B)(6) 2021. THE PATIENT WAS PLACED IN A BRACE TO STABILIZE THE LEG BUT THE SURGEON SAID HE WASN¿T WEARING IT CONSISTENTLY. THE SURGEON SAID HE FELL AGAIN AROUND THE END OF SEPTEMBER AND THAT HE BELIEVED THE PATIENT TO POSSIBLY BE INFECTED. THE SURGEON ELECTED TO REMOVE ALL THE IMPLANTS AND LEAVE THE PATIENT WITH A GIRDLE STONE AND TEY TO CLEAR THE INFECTION. DOI: (B)(6) 2021 (STEM), (B)(6) 2021 (BIPOLAR HEAD AND FEMORAL HEAD). DOR: (B)(6) 2021. AFFECTED SIDE: RIGHT HIP.

    Patient problems: Fall; Unspecified Infection

    MAUDE report 12636772 ↗
  • InjuryOct 4, 2021Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT HAD PARKINSON¿S AND FELL AND DISLOCATED HIS HIP. THE SURGEON ELECTED TO LENGTH THE BALL TO TIGHTEN THE JOINT. DOI: (B)(6) 2021. DOR: (B)(6) 2021. AFFECTED SIDE: UNKNOWN HIP.

    Patient problems: Fall; Joint Dislocation

    MAUDE report 12568079 ↗
  • InjuryJan 5, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE SURGEON EXPLAINED THE PATIENT WAS FEELING SOME DISCOMFORT IN THEIR RIGHT HIP. SHE BELIEVED IT TO BE DUE TO THE WEARING OF THE BIPOLAR COMPONENT ON THE PATIENT'S NATIVE ACETABULUM. THE SURGEON BELIEVED IT WOULD BE BEST TO CONVERT THIS PATIENT'S BIPOLAR INTO A TOTAL HIP. THE BIPOLAR COMPONENT AND 28MM HEAD WERE REMOVED, ALLOWING AMPLE ROOM FOR THE SURGEON TO REAM OUT THE ACETABULUM. AFTER REAMING THE ACETABULUM, A 54MM GRIPTION MULTI HOLE CUP WAS IMPLANTED. A TRIAL REDUCTION WAS PERFORMED AFTER IMPLANTING A 54X36MM +4 10 DEGREE LINER. THE PATIENT HAD LOST SOME LENGTH, SO A +15.5 WAS TRIALED AND FOUND TO BE SATISFACTORY. THE REAL HEAD WAS OPENED AND IMPLANTED. THE HIP WAS REDUCED AND FOUND TO BE STABLE. THE CLOSING PROCESS BEGAN. DOI: (B)(6) 2019, DOR: (B)(6) 2020, RIGHT HIP.

    Patient problems: Discomfort

    MAUDE report 11116621 ↗
  • InjuryDec 29, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED DUE TO INFECTION. DOI: (B)(6) 2020, DOR: (B)(6) 2020, RIGHT HIP.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 11087380 ↗
  • MalfunctionSep 15, 2020Expiration Date Error; Expiration Date Error

    (B)(6) HAS IMPLANTED, THE (B)(6) 2020, A PRODUCT WITH AN EXPIRATION DATE ON JULY 2020.

    Patient problems: Insufficient Information; No Code Available

    MAUDE report 10536478 ↗
  • InjuryJul 14, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT HAD PRIOR BI-POLAR HEMI ARTHROPLASTY WHICH BECAME INFECTED. SURGEON PERFORMED I&D OF THE HIP, WITH SWAP OF FEMORAL HEAD COMPONENTS. WAS SURGERY DELAYED DUE TO THE REPORTED EVENT? UNKNOWN, WAS PROCEDURE SUCCESSFULLY COMPLETED? UNKNOWN, WERE FRAGMENTS GENERATED? UNKNOWN, IF YES, WERE THEY REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION? UNKNOWN, PATIENT STATUS/ OUTCOME / CONSEQUENCES UNKNOWN, WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: UNKNOWN, IS THE PATIENT PART OF A CLINICAL STUDY UNKNOWN, (B)(4), DEVICE PROPERTY OF NONE, DEVICE IN POSSESSION OF NONE, (B)(4), DEVICE PROPERTY OF NONE, DEVICE IN POSSESSION OF NONE. BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INFORMATION WILL BE MADE AVAILABLE, THE ADDITIONAL INFORMATION WILL BE SUBMITTED THROUGH CST. TRUE.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 10269119 ↗
  • InjurySep 19, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT HAD INFECTION. DOI: (B)(6) 2019; DOR: (B)(6) 2019; LEFT HIP.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 9088461 ↗
  • InjurySep 19, 2018Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available; Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available

    PATIENT WAS REVISED TO ADDRESS PAIN WITH LOSS OF ACETABULAR CARTILAGE DUE TO FAILED RIGHT HEMIARTHROPLASTY. REVISION NOTES REPORTED WEAR TO THE ACETABULUM. DOI: (B)(6) 2004 - DOR: (B)(6) 2010; (RIGHT HIP).

    Patient problems: Burning Sensation; Damage to Ligament(s); Limited Mobility Of The Implanted Joint; Loss of Range of Motion; Not Applicable; Pain; Paresthesia; Swelling; Swelling/ Edema

    MAUDE report 7890852 ↗
  • InjuryAug 27, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT DISLOCATED A COUPLE WEEKS POST OP. TWO SEPARATE CLOSE REDUCTIONS WERE DONE AND OPEN REDUCTION WAS DONE AND DETERMINED THAT THE HIP WAS UNSTABLE. THE PATIENT WAS CONVERTED TO A TOTAL HIP TO ACHIEVE A STABLE HIP JOINT. DOI: (B)(6) 2018; DOR: (B)(6) 2018; LEFT HIP.

    Patient problems: Joint Dislocation

    MAUDE report 7818644 ↗
  • InjuryJun 1, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT WAS REVISED TO ADDRESS INFECTION OF HEMIARTHROPLASTY. I&D WITH BIPOLAR HEAD EXCHANGE. DOI: UNKNOWN; DOR: (B)(6) 2018; RIGHT HIP.

    Patient problems: Not Applicable; Unspecified Infection

    MAUDE report 7562077 ↗
  • InjuryMay 4, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    DER STATES THAT THE PATIENT HAD LEFT HIP PAIN AND DOCTOR WANTED CONVERT FROM A BIPOLAR TO A TOTAL HIP. DOI: (B)(6) 2017; DOR: (B)(6) 2018; LEFT HIP.

    Patient problems: Not Applicable; Pain

    MAUDE report 7486631 ↗
  • MalfunctionJan 11, 2018Device Expiration Issue; Device Expiration Issue

    THE SIZE 53 BIPOLAR IMPLANT HAD AN EXPIRATION DATE OF (B)(6) 2017. THE SURGEON WAS INFORMED IMMEDIATELY. THE SURGEON CHOSE TO MOVE FORWARD WITH THE EXPIRED IMPLANT. DOE: (B)(6) 2017.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7181783 ↗
  • InjuryJan 10, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT WAS REVISED TO ADDRESS DISLOCATION. DOI: (B)(6) 2017; DOR: (B)(6) 2017; RIGHT HIP.

    Patient problems: Joint Dislocation

    MAUDE report 7177883 ↗
  • InjuryJan 4, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT WAS REVISED TO ADDRESS INFECTION. DOI: (B)(6) 2017; DOR: (B)(6) 2017. LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 7164810 ↗
  • InjuryJan 4, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT WAS REVISED TO ADDRESS INFECTION. DOI: (B)(6) 2017, DOR: (B)(6) 2017, LEFT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 7163597 ↗
  • InjuryNov 20, 2017Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT WAS REVISED TO ADDRESS DISLOCATION.

    Patient problems: Joint Dislocation

    MAUDE report 7047609 ↗

Other Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices

All Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices →