The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295102922), received between Sep 27, 2021 and Sep 27, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 27, 2021Break; Break
PROCEDURE RIGHT TOTAL SHOULDER REPLACEMENT WITH GLOBAL APG+ AND GLOBAL ICON. THE MODULE HAD BEEN DISPATCHED WITH 2 X BREAKAWAY GUIDE PINS. DURING PROCEDURE THE 2.5MM BREAKAWAY GUIDE PIN SNAPPED AT THE FIRST BREAK POINT PROXIMAL TO PATIENT. THIS OCCURRED AFTER THE CENTRAL HOLE WAS DRILLED. TIP OF WIRE COULDN¿T BE SEEN, X-RAYS TAKEN. SURGEON HAD TO BURR HOLE CENTRALLY THROUGH GLENOID BUT HAD TO THEN PERFORM A CORACOID OSTEOTOMY TO ACCESS AND REMOVE THE SNAPPED PART OF THE WIRE. APPROXIMATELY ONE HOUR WAS ADDED TO THE PROCEDURE TO REMOVE THE BROKEN WIRE. ONCE THE WIRE WAS REMOVED THE SURGERY WAS COMPLETED WITHOUT FURTHER COMPLICATION. DOI: (B)(6) 2021. RIGHT SHOULDER.
Patient problems: Insufficient Information
MAUDE report 12532598 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page