Depuy International Ltd · P.F.C. Total Hip System FEMORAL HEAD Diameter 32mm +5 10/12 TAPER · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295207634), received between May 29, 2020 and Mar 12, 2025 — classified as 3 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated2
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Joint Dislocation2
  • Fall1
  • Joint Laxity1
  • No Code Available1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 12, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT REVISION SURGERY WAS PERFORMED DUE TO DISLOCATION. NO FURTHER INFORMATION IS PROVIDED.

    Patient problems: Joint Dislocation

    MAUDE report 21585386 ↗
  • InjuryJul 26, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SURGEON PERFORMED A HIP REVISON, PRIMARY HIP ARTHROPLASTY WAS PERFORMED IN 2018. PATIENT COMPLAINED OF HIP SLIPPING, SURGEON SUSPECTED THIS WAS DUE TO THE LINER BEING DISASSOCIATED FROM THE CUP. LINER AND CUP WERE EXPLANTED AND REPLACED WITH A TRIDENT CUP. DOI: 2018. DOE: (B)(6) 2024.

    Patient problems: Joint Laxity

    MAUDE report 19839756 ↗
  • InjuryMay 29, 2020Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT HAS FALLEN A FEW TIMES AND IS A MULTIPLE DISLOCATOR. PULLING THE LINER AND GOING TO A CONSTRAINED LINER WITH A HEAD EXCHANGE. NO COMPLAINTS OR PROBLEMS WITH OUR IMPLANTS. DOI: (B)(6) 2004; DOR: (B)(6) 2020; LEFT HIP.

    Patient problems: Fall; Joint Dislocation; No Code Available

    MAUDE report 10102768 ↗

Other Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices