SPECIALIST 96-6384Recalls & reported problems

Depuy (Ireland) · SPECIALIST 2 TIBIAL TRAY INSERTER · Class 1

All models of SPECIALIST (80)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 10603295248262), received between Oct 10, 2018 and Jan 3, 2024 — classified as 12 malfunctions.

The most frequently reported specific device problem is “Break” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break8
  • Device-Device Incompatibility2
  • Naturally Worn2
  • Crack1
  • Device Damaged Prior to Use1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9
  • No Consequences Or Impact To Patient3

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 3, 2024Device-Device Incompatibility; Material Deformation; Naturally Worn; Device-Device Incompatibility; Material Deformation; Naturally Worn

    THE TIBIAL TRAY INSERT IS DAMAGED, IT DOES NOT ALLOW TO GRASP THE TIBIAL PLATE, WEAR IS EVIDENCED AND PREVENTS THE CORRECT COUPLING. THERE WAS NO NEGATIVE CONSEQUENCE TO THE PATIENT OR IN THE PROCEDURE, SURGEON DECIDED TO PLACE THE TIBIA IMPLANT MANUALLY AND THEN IMPACT, BUT IT IS NECESSARY TO CHANGE THE PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18436161 ↗
  • MalfunctionDec 9, 2022Break; Break

    IT WAS REPORTED THAT THE INSTRUMENT WAS BROKEN WHERE IT CONNECTS WITH THE POSTERIOR TIBIAL IMPLANT. FOUND BROKEN IN SPD. IT WAS NOT USED IN SURGERY. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15949967 ↗
  • MalfunctionApr 27, 2022Break; Break

    INSTRUMENT BROKE DURING IMPLANTATION. ALL PIECES WERE RETRIEVED. NO ADVERSE AFFECTS ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14220354 ↗
  • MalfunctionFeb 9, 2022Break; Naturally Worn; Break; Naturally Worn

    INSTRUMENT IS BROKEN DUE TO WEAR AND TEAR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13496088 ↗
  • MalfunctionJan 7, 2022Break; Break

    RING AND SCREW MECHANISM IS BROKEN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13196872 ↗
  • MalfunctionDec 21, 2021Break; Break

    METAL PRONG BROKE OFF, NOT USED IN SURGERY. PIECE RETRIEVED. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13053555 ↗
  • MalfunctionApr 12, 2021Break; Break

    IT WAS REPORTED THAT THE IMPACTOR BROKE DURING TIBIA IMPACTION. THE PART THAT BROKE WAS THE SMALL LIPPED PART THAT HOOKS THE ANTERIOR PORTION OF THE TIBIA. ALL PIECES WERE RETRIEVED. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11649040 ↗
  • MalfunctionDec 7, 2020Break; Break

    IT WAS REPORTED THAT THE ONE OF THE TABS ON THE TIBIAL TRAY INSERTER HAS CHIPPED OFF. THIS DID NOT OCCUR DURING SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10959998 ↗
  • MalfunctionNov 23, 2020Crack; Crack

    IT WAS REPORTED THAT SP2 POLY PS IMPACTOR HAS CRACKED FROM USE. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10888074 ↗
  • MalfunctionNov 9, 2018Break; Break

    ATTACHED SLAPHAMMER 1 LIP ON INSTRUMENT BROKE AFTER A COUPLE BACK SLAPS THAT FIT INTO THE FIXED BEARING TIBIAL TRAY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8055432 ↗
  • MalfunctionOct 17, 2018Device Damaged Prior to Use; Device Damaged Prior to Use

    DAMAGED ITEMS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7974005 ↗
  • MalfunctionOct 10, 2018Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT THE TIBIAL INSERTER WOULD NOT TIGHTEN ONTO THE TIBIAL BASE PLATE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7953345 ↗

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page