ATTUNE 2545-05-509Recalls & reported problems
Depuy (Ireland) · ATTUNE KNEE SYSTEM BALANCING CUTTING BLOCK SIZE 9 · Class 1
All models of ATTUNE (1475)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295481799), received between Sep 27, 2022 and Sep 27, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 27, 2022Device-Device Incompatibility; Device-Device Incompatibility
THE SURGEON INFORMED VIA EMAIL THAT HE FELT HIS MTO IM DRILL GUIDE POSITIONS THE IM HOLE TOO LOW FOR LARGER PATIENTS, SO THAT ON A SIZE 9 AND 10 BALANCE BLOCK, THERE IS NOT ENOUGH EXCURSION OF THE THREADED KNOB BEFORE IT DISENGAGES. IT IS NOT CLEAR WHETHER THIS EVENT IS A DIRECT OBSERVATION FROM SURGERY, OR SOMETHING THAT WAS NOTICED OUTSIDE OF SURGERY ON A FOAM BONE. NO PATIENT HARM IS NOTED AS UNCLEAR IF PATIENT INVOLVED. NOTE ¿ FROM THE DESCRIPTION, THIS WOULD APPEAR TO BE AN OBSERVATION BASED ON THE DESIGN RATHER THAN SOMETHING THAT IS BATCH OR LOT SPECIFIC. THERE IS NO INFORMATION ON HOW MANY ITEMS ARE INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15495339 ↗
Other INSTRUMENT, CUTTING, ORTHOPEDIC devices
- SIGMA LCS 9505-01-230Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC95 reports
- ATTUNE 2544-00-522Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC58 reports
- SIGMA LCS 9505-01-229Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC56 reports
- SIGMA 2024-40-100Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC43 reports
- ATTUNE 2545-00-158Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC41 reports
- ATTUNE 2545-00-156Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC41 reports
- SIGMA 2024-40-200Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC40 reports
- ATTUNE 2545-00-155Depuy (Ireland) · INSTRUMENT, CUTTING, ORTHOPEDIC39 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page