Deltec 21-2770-24Recalls & reported problems
Icu Medical, Inc. · Class 2
All models of Deltec (97)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 16
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 10610586025631), received between Jul 20, 2017 and Aug 8, 2025 — classified as 16 malfunctions.
The most frequently reported specific device problem is “Complete Blockage” (6 reports).
1 other recall cover devices cleared under the same FDA submission (K021999); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Complete Blockage6
- Obstruction of Flow6
- Protective Measures Problem2
- Coagulation in Device or Device Ingredient1
- Improper Flow or Infusion1
- Material Twisted/Bent1
- Partial Blockage1
Patient problems
- No Clinical Signs, Symptoms or Conditions14
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 8, 2025Complete Blockage; Complete Blockage
IT WAS REPORTED THAT SALINE SOLUTION COULD NOT BE INJECTED INTO THE DEVICE DURING THE PRE-TEST BEFORE THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22754900 ↗MalfunctionJul 22, 2025Obstruction of Flow; Obstruction of Flow
IT WAS REPORTED THAT THERE WAS A RESISTANCE WHEN CUSTOMER TRIED THE TEST DOSE. IT IS UNCLEAR IF IT WAS INSERTED INTO THE PORT. THE EVENT OCCURRED DURING UNKNOWN TIME AT FACILITY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22569187 ↗MalfunctionJul 8, 2025Complete Blockage; Coagulation in Device or Device Ingredient; Obstruction of Flow; Complete Blockage; Coagulation in Device or Device Ingredient; Obstruction of Flow
IT WAS REPORTED THAT THERE WAS A LINE BLOCKAGE, AS SALINE DID NOT FLOW. THE EVENT OCCURRED DURING PRIMING AT THE FACILITY, PRIOR TO PATIENT USE. NO PATIENT HARM OR ADVERSE EVENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22441489 ↗MalfunctionMay 12, 2025Obstruction of Flow; Obstruction of Flow
IT WAS REPORTED THAT THE LINE HAD BLOCKAGE. SALINE DID NOT SEEM TO FLOW EVEN AFTER THE CLAMP WAS RELEASED. THERE WAS NO DISINFECTION OR STERILIZATION, AND NO INFECTIOUS DISEASE OCCURRED. THIS OCCURRED BEFORE PATIENT USE DURING PRIMING. THERE NO PATIENT HARM OR ADVERSE EVENT REPORTED AS A RESULT OF THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22006392 ↗MalfunctionMay 1, 2025Complete Blockage; Complete Blockage
IT WAS REPORTED THAT, "IT IS IMPOSSIBLE TO PURGE THE NEEDLE." THERE IS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21942560 ↗MalfunctionMay 1, 2025Complete Blockage; Complete Blockage
IT WAS REPORTED THAT "IT WAS IMPOSSIBLE TO PURGE THE NEEDLE." THE NURSES CHANGED THE NEEDLE WITH ONE OF THE SAME LOT NUMBER. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21942519 ↗MalfunctionMar 26, 2025Complete Blockage; Complete Blockage
IT WAS REPORTED THAT THE DEVICE WAS UNABLE TO INJECT LIQUID WITH A SYRINGE. THE EVENT OCCURRED IN THE FACILITY. THERE WAS NO DISINFECTION OR STERILIZATION, AND NO INFECTIOUS DISEASE OCCURRED. THIS OCCURRED BEFORE PATIENT USE, DURING PRIMING. THERE WAS NO PATIENT INVOLVEMENT, AND NO PATIENT HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21698468 ↗MalfunctionMar 18, 2025Obstruction of Flow; Obstruction of Flow
IT WAS REPORTED THAT THE LINE HAD BLOCKAGE. SALINE DID NOT SEEM TO FLOW EVEN AFTER THE CLAMP WAS RELEASED. THERE WAS NO DISINFECTION OR STERILIZATION, AND NO INFECTIOUS DISEASE OCCURRED. THIS OCCURRED BEFORE PATIENT USE DURING PRIMING. THERE NO PATIENT HARM OR ADVERSE EVENT REPORTED AS A RESULT OF THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21638335 ↗MalfunctionJan 14, 2025Complete Blockage; Complete Blockage
IT WAS REPORTED THAT "WHEN PRIMING, THE NEEDLE TIP CANNOT BE FILLED DUE TO RESISTANCE. THERE SEEMS TO BE A BLOCKAGE ALONG THE WAY". THE EVENT OCCURRED DURING PRIMING, NO PATIENT INVOLVEMENT AND NO PATIENT HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21152401 ↗MalfunctionSep 22, 2022Improper Flow or Infusion; Improper Flow or Infusion
IT WAS REPORTED THAT WHEN PERFORMING PRIMING AT A PRE-USE CHECK, THE CUSTOMER NOTICED MEDICAL FLUID DID NOT PASS THROUGH THE PRODUCT DUE AN OCCLUSION IN IT.. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15466980 ↗MalfunctionSep 14, 2022Obstruction of Flow; Obstruction of Flow
IT WAS REPORTED THAT DURING PRE-USE FLUSH THERE WAS AN ABSENCE OF FLUID THAT PASSED THROUGH THE DEVICE. NO PATIENT INJURY OR INVOLVEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15417167 ↗MalfunctionSep 14, 2022Obstruction of Flow; Obstruction of Flow
IT WAS REPORTED THAT DURING PRE-USE FLUSH THERE WAS AN ABSENCE OF FLUID THAT PASSED THROUGH THE DEVICE. NO PATIENT INJURY OR INVOLVEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15417163 ↗MalfunctionSep 12, 2022Partial Blockage; Partial Blockage
IT WAS REPORTED THAT WHEN PERFORMING A FLUSHING AT A PRE-USE CHECK, THE CUSTOMER FOUND AN OCCLUSION IN THE PRODUCT'S TUBE LINE. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15405439 ↗MalfunctionMay 18, 2021Material Twisted/Bent; Material Twisted/Bent
INFORMATION RECEIVED A SMITHS MEDICAL IMPLANTABLE PORTS/DELTEC GRIPPER PLUS NEEDLES MALFUNCTIONED. THE REPORT INDICATED DURING ACCESSING PORT FOR CHEMO TREATMENT THE DEVICE FLUSHED WELL PRIOR TO INSERTION. UPON INSERTION LOUD "CLICK" HEARD AND NEEDLE BENT TO APPROX. 45 DEGREES. DEVICE IMMEDIATELY REMOVED AND REPORTED WAS IN INTACT. PORT RE-ACCESSED WITH ANOTHER GRIPPER AND HAD NO ISSUE. NO ADVERSE PATIENT EVENTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11845105 ↗MalfunctionJul 21, 2017Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE NEEDLE STICK PREVENTION MECHANISM OF A DELTEC® GRIPPER PLUS® SAFETY NEEDLE DID NOT WORK, AND THE NEEDLE COULD NOT BE STOWED IN THE PRODUCT. ANOTHER NEEDLE WAS USED. NO INJURY WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6732395 ↗MalfunctionJul 20, 2017Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE NEEDLE STICK PREVENTION MECHANISM OF A DELTEC® GRIPPER PLUS® SAFETY NEEDLE DID NOT WORK, AND THE NEEDLE COULD NOT BE STOWED IN THE PRODUCT. ANOTHER NEEDLE WAS USED. NO INJURY WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6729427 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K021999. One submission often covers many models, so check the product and lot details in each record.
- Z-0253-2020 · Jul 15, 2019 · TerminatedPort full Access Tray Product Code: DT19330
Other Needle, hypodermic, single lumen devices
- BD Nano 2nd Gen 320550Becton Dickinson Pen Limited · Needle, hypodermic, single lumen2,044 reports
- BD SafetyGlide 305916Becton, Dickinson And Company · Needle, hypodermic, single lumen1,767 reports
- BD Nano Ultra-Fine 320122Becton Dickinson Pen Limited · Needle, hypodermic, single lumen601 reports
- N/A 305106Becton, Dickinson And Company · Needle, hypodermic, single lumen1 recall467 reports
- N/A 305110Becton, Dickinson And Company · Needle, hypodermic, single lumen418 reports
- BD Safe-Clip 328235Becton, Dickinson and Company Inc · Needle, hypodermic, single lumen268 reports
- BD Ultra-Fine 320109Becton Dickinson Pen Limited · Needle, hypodermic, single lumen229 reports
- BD AutoShield Duo 329515Becton, Dickinson And Company · Needle, hypodermic, single lumen208 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page