McKesson 102-N2558S3Recalls & reported problems
Mckesson Medical-Surgical Inc. · Safety Hypodermic Needles 25G x 5/8 in (100/bx, 8/cs) · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10612479246406), received between Oct 16, 2024 and Mar 30, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Malposition of Device” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Malposition of Device5
- Break1
Patient problems
- Needle Stick/Puncture3
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 30, 2026Malposition of Device
TERUMO MEDICAL CORPORATION RECEIVED THE FOLLOWING INFORMATION: IT WAS REPORTED THAT THE PRODUCT HAS BEEN BENDING DURING USE, FAILING TO LOCK PROPERLY WITH THE SAFETY MECHANISM, AND IN SOME CASES, THE NEEDLE REMAINS EXPOSED EVEN AFTER THE SAFETY LOCK HAS BEEN ENGAGED. ADDITIONAL INFORMATION WAS RECEIVED ON 05-MAR-2026: HARD-SURFACE ACTIVATION WAS THE METHOD USED. THE HYPODERMIC NEEDLE WAS INSERTED INTO THE INTRAMUSCULAR AND SUBCUTANEOUS TISSUES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24726834 ↗MalfunctionMar 30, 2026Malposition of Device
TERUMO MEDICAL CORPORATION RECEIVED THE FOLLOWING INFORMATION: IT WAS REPORTED THAT THE PRODUCT HAS BEEN BENDING DURING USE, FAILING TO LOCK PROPERLY WITH THE SAFETY MECHANISM, AND IN SOME CASES, THE NEEDLE REMAINS EXPOSED EVEN AFTER THE SAFETY LOCK HAS BEEN ENGAGED. ADDITIONAL INFORMATION WAS RECEIVED ON 05-MAR-2026: HARD-SURFACE ACTIVATION WAS THE METHOD USED. THE HYPODERMIC NEEDLE WAS INSERTED INTO THE INTRAMUSCULAR AND SUBCUTANEOUS TISSUES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24726776 ↗MalfunctionFeb 11, 2026Malposition of Device
TERUMO RECEIVED THE FOLLOWING REPORTED INFORMATION: THE SLIT THAT THE NEEDLE GOES INTO APPEARED TO BE ATTACHED ALL THE WAY ACROSS AND PUSHED THE NEEDLE OUT INSTEAD OF ALLOWING IT TO GO INTO THE SAFETY CAP. ADDITIONAL INFORMATION WAS RECEIVED ON 15JAN2026: THERE WAS AN EMPLOYEE NEEDLE STICK/EXPOSURE WHICH REQUIRED THE EXPOSURE PROTOCOL/PROCEDURES POST STICK. ADDITIONAL INFORMATION WAS RECEIVED ON 28JAN2026: PEDIATRIC VACCINES HAD TAKEN PLACE PRIOR TO ATTEMPTED ACTIVATION. THE PATIENT WAS NOT AFFECTED IN ANY WAY. THE PROCEDURES (INJECTIONS) WERE COMPLETED. THE STAFF REPORTED THAT THEY WERE ATTEMPTING TO ACTIVATE THE SAFETY ON A HARD SURFACE. THE NURSE WAS STUCK IN THEIR LEFT-HAND INDEX FINGER WHILE ATTEMPTING TO ENGAGE THE SAFETY. THE EMPLOYEE WAS SEEN AT THE WORKPLACE WELLNESS AT THE LOCAL HOSPITAL AND BBP LABS WERE DRAWN PER THE BBP POLICY. SOURCE LABS WERE NOT OBTAINED AS THEY WERE LOW RISK. THE NEEDLE STICK DID NOT CAUSE BLOOD LOSS, OR REQUIRE ADDITIONAL TREATMENT. (ASIDE FROM SIMPLE FIRST AID). THE STAFF MEMBER WAS STABLE AND RETURNED TO NORMAL DUTIES.
Patient problems: Needle Stick/Puncture
MAUDE report 24313519 ↗MalfunctionFeb 11, 2026Malposition of Device
TERUMO RECEIVED THE FOLLOWING REPORTED INFORMATION: THE SLIT THAT THE NEEDLE GOES INTO APPEARED TO BE ATTACHED ALL THE WAY ACROSS AND PUSHED THE NEEDLE OUT INSTEAD OF ALLOWING IT TO GO INTO THE SAFETY CAP. ADDITIONAL INFORMATION WAS RECEIVED ON 15JAN2026: THERE WAS AN EMPLOYEE NEEDLE STICK/EXPOSURE WHICH REQUIRED THE EXPOSURE PROTOCOL/PROCEDURES POST STICK. ADDITIONAL INFORMATION WAS RECEIVED ON 28JAN2026: PEDIATRIC VACCINES HAD TAKEN PLACE PRIOR TO ATTEMPTED ACTIVATION. THE PATIENT WAS NOT AFFECTED IN ANY WAY. THE PROCEDURES (INJECTIONS) WERE COMPLETED. THE STAFF REPORTED THAT THEY WERE ATTEMPTING TO ACTIVATE THE SAFETY ON A HARD SURFACE. THE NURSE WAS STUCK IN THEIR LEFT-HAND INDEX FINGER WHILE ATTEMPTING TO ENGAGE THE SAFETY. THE EMPLOYEE WAS SEEN AT THE WORKPLACE WELLNESS AT THE LOCAL HOSPITAL AND BBP LABS WERE DRAWN PER THE BBP POLICY. SOURCE LABS WERE NOT OBTAINED AS THEY WERE LOW RISK. THE NEEDLE STICK DID NOT CAUSE BLOOD LOSS, OR REQUIRE ADDITIONAL TREATMENT. (ASIDE FROM SIMPLE FIRST AID). THE STAFF MEMBER WAS STABLE AND RETURNED TO NORMAL DUTIES.
Patient problems: Needle Stick/Puncture
MAUDE report 24313518 ↗MalfunctionJan 16, 2025Break; Break
TERUMO MEDICAL RECEIVED AN FDA MEDWATCH REPORT # MW5162171. THE EVENT DESCRIPTION STATES THAT: DURING A CHILD IMMUNIZATION CLINIC, TWO NURSES REPORTED THAT THE NEEDLES WERE BREAKING WHEN TRYING TO DRAW UP THE VACCINE FROM THE VIAL. ADDITIONALLY, CHILDREN REPORTED DISCOMFORT WITH VACCINE ADMINISTRATIONS THAT WOULDN'T NORMALLY CAUSE DISCOMFORT. THE NURSES ALSO DESCRIBED THAT THE NEEDLES FELT DULL. ADDITIONAL INFORMATION WAS RECEIVED ON 17 DEC 2024: DURING PREPARATION FOR VACCINE DELIVERY, PRIOR TO PATIENT INTERACTION, SEVERAL ISSUES WITH THE NEEDLES WERE REPORTED. IN ONE INSTANCE, THE NEEDLE BROKE OFF AT THE HUB, WHILE IN OTHER CASES, THE SHAFT OF THE NEEDLE BROKE OFF. ADDITIONALLY, A SECOND NURSE REPORTED THAT THE NEEDLE BENT WHILE DRAWING UP THE VACCINE, NECESSITATING ITS REPLACEMENT BEFORE PATIENT INJECTION. TO RESOLVE THESE ISSUES AND CONTINUE WITH VACCINE DELIVERY AS INTENDED, A NEW NEEDLE HAD TO BE USED TO DRAW UP THE VACCINE. IN AT LEAST ONE CASE, THE VACCINE HAD TO BE DISCARDED, AND A NEW DOSE WAS DRAWN UP. THIS RESULTED IN A LONGER WAIT TIME FOR THE PATIENT, AS THE VACCINE TOOK LONGER TO PREPARE ACCURATELY FOR ADMINISTRATION. ADDITIONAL INFORMATION WAS RECEIVED ON 30 DEC 202
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21173360 ↗MalfunctionOct 16, 2024Malposition of Device; Malposition of Device
THE USER FACILITY THAT AN EMPLOYEE WAS STUCK WITH THE INVOLVED NEEDLE. THE EMPLOYEE HAD JUST FINISHED GIVING A PATIENT A FLU SHOT. WHEN THE EMPLOYEE ENGAGED THE SAFETY, THE NEEDLE BENT INSTEAD OF REMAINING STRAIGHT AND PRICKED HER FINGER. ADDITIONAL INFORMATION WAS RECEIVED ON 18 SEPT 2024: THE NEEDLE WAS NOT CONFIRMED TO BE SUCCESSFULLY ACTIVATED WITHIN THE SAFETY SHEATH POST-PATIENT INJECTION. THE HEALTHCARE PROFESSIONAL (HCP) WHO INCURRED THE NEEDLESTICK USED THEIR FINGER FOR ACTIVATION. THE NEEDLESTICK DID NOT REQUIRE ADDITIONAL MEDICAL INTERVENTION BEYOND SIMPLE FIRST AID, AND THE HCP WAS ABLE TO CONTINUE NORMAL DUTIES AFTERWARD. THE HCP NOW CONSIDERED THE PATIENT DUE TO THE NEEDLESTICK. THE PATIENT AGREED TO HAVE THEIR BLOOD DRAWN FOR SOURCE PERSON TESTING.
Patient problems: Needle Stick/Puncture
MAUDE report 20465903 ↗
FDA clearance and classification
The FDA regulates product code FMI (needle, hypodermic, single lumen) under 21 CFR 880.5570 as a Class II device. 21 CFR 880.5570 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the McKesson 102-N2558S3
Has the McKesson 102-N2558S3 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10612479246406), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the McKesson 102-N2558S3?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Oct 16, 2024 and Mar 30, 2026. In those reports, the most common specific device problems are “Malposition of Device” (5) and “Break” (1); the most common patient problem is “Needle Stick/Puncture” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the McKesson 102-N2558S3?
None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the McKesson 102-N2558S3, and is it still sold?
The FDA's device database lists Mckesson Medical-Surgical Inc. as the company responsible for it (brand McKesson, model 102-N2558S3). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Needle, Hypodermic, Single Lumen devices
- BD Nano 2nd Gen 320550Becton Dickinson Pen Limited · Needle, hypodermic, single lumen1,892 reports
- BD SafetyGlide 305916Becton, Dickinson And Company · Needle, hypodermic, single lumen1,768 reports
- BD Nano Ultra-Fine 320122Becton Dickinson Pen Limited · Needle, hypodermic, single lumen566 reports
- N/A 305106Becton, Dickinson And Company · Needle, hypodermic, single lumen1 recall465 reports
- N/A 305110Becton, Dickinson And Company · Needle, hypodermic, single lumen418 reports
- BD Safe-Clip 328235Becton, Dickinson and Company Inc · Needle, hypodermic, single lumen268 reports
- BD Ultra-Fine 320109Becton Dickinson Pen Limited · Needle, hypodermic, single lumen208 reports
- BD AutoShield Duo 329515Becton, Dickinson And Company · Needle, hypodermic, single lumen200 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page