1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier, 1 still open.

9 other recalls cover devices cleared under the same FDA submission (K061037, K212380); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Aug 10, 2023Class IIOpen, Classified

    Internal testing on returned product from this lot confirmed that some PDS" II (polydioxanone) Sutures from this lot did not meet tensile strength requirement.

    Z-2616-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K212380 on Feb 22, 2022 (decision: Substantially Equivalent). Submitted by ETHICON, Inc. as “PDS Plus Antibacterial (Polydioxanone) Sterile Synthetic Absorable Surgical Suture”. The FDA review took 204 days. FDA record ↗

Cleared through 510(k) K061037 on Jul 14, 2006 (decision: Substantially Equivalent). Submitted by ETHICON, Inc. as “Pds Plus Antibacterial Suture”. The FDA review took 91 days. FDA record ↗

The FDA regulates product code NEW (suture, surgical, absorbable, polydioxanone) under 21 CFR 878.4840 as a Class II device. 21 CFR 878.4840 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K061037, K212380. One submission often covers many models, so check the product and lot details in each record.

  • Z-2147-2024 · May 10, 2024 · Open, Classified
    PDS Plus Antibacterial (polydioxanone) Suture - Intended for use in general soft tissue approximation, including use in paediatric cardiovascular tissue, in microsurgery and in oph
  • Z-1571-2023 · Mar 31, 2023 · Open, Classified
    PDS Plus Antibacterial (polydioxanone) Suture - PDS PLUS CLR 27IN(70CM) USP3-0(M2) S/A PC-25 PRIME. Intended for use in general soft tissue approximation, including use in pediatri
  • Z-1135-2019 · Mar 12, 2019 · Terminated
    VICRYL PLUS Sutures: VICRYL PLUS SUTURE 18"(45CM) 3-0 VIO VICRYL PLUS SUTURE 18"(45CM) 0 UND VICRYL PLUS SUTURE 18"(45CM) 0 VIO VICRYL PLUS SUTURE 18"(45CM) 0 VIO) VICRYL PLUS SU
  • Z-2532-2018 · Jun 8, 2018 · Terminated
    PDS Plus Antibacterial (Polydioxanone) Suture-PDS PLUS Undyed Suture 45cm (18") 4-0 Single Armed PS-4 Prime Needle Product Code: PDP507G (GTIN 10705031203983)
  • Z-2533-2018 · Jun 8, 2018 · Terminated
    PDS Plus Antibacterial Suture-PDS PLUS Undyed Suture 45cm (18") 5-0 Single Armed P-3 Prime Needle Product Code: PDP493G (GTIN 10705031203945)
  • Z-1339-2018 · Jan 10, 2018 · Terminated
    PDS Plus Antibacterial (Polydioxanone) Suture Size 1 PDS PLUS Violet 27 Single Armed OS-4 Needle
  • Z-1338-2018 · Jan 10, 2018 · Terminated
    PDS Plus Antibacterial (Polydioxanone) Suture Size 0 PDS Plus Violet 36 Single Armed CT-1 Needle
  • Z-1340-2018 · Jan 10, 2018 · Terminated
    PDS Plus Antibacterial (Polydioxanone) Suture Size 0 PDS Plus Violet 36 Single Armed CTB-1 Needle
  • Z-1314-2009 · Feb 2, 2009 · Terminated
    PDS Plus Antibacterial (polydioxanone) Suture Sutures are intended for general soft tissue approximation and/or ligation.

Common questions about the PDS PDP662H

Has the PDS PDP662H been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-2616-2023 (Class II), began on Aug 10, 2023: Internal testing on returned product from this lot confirmed that some PDS" II (polydioxanone) Sutures from this lot did not meet tensile strength requirement. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the PDS PDP662H FDA approved?

It was cleared through 510(k) K061037 on Jul 14, 2006; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the PDS PDP662H MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the PDS PDP662H, and is it still sold?

The FDA's device database lists Ethicon, LLC as the company responsible for it (brand PDS, model PDP662H). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SUTURE, SURGICAL, ABSORBABLE, POLYDIOXANONE devices