BRITE TIP 401745MRecalls & reported problems
Cordis US Corp. · SI BRITE TIP 7F 45CM STR · Class 2
All models of BRITE TIP (20)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705032000338), received between Jun 11, 2019 and Jul 8, 2022 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove1
- Material Frayed1
- Material Split, Cut or Torn1
- Unraveled Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 8, 2022Difficult to Remove; Unraveled Material; Difficult to Remove; Unraveled Material
AS REPORTED, A 7F STR BRITE TIP CATHETER SHEATH INTRODUCER (CSI) KINKED IN "THE BIFURCATION MASSIVELY". IT WAS "HEAVY" TO PULL THE DEVICES OUT, WITH THE HANDLING THE BRITE TIP CSI EXPANDED NEAR THE KINK. THE MATERIAL "GOT LESS" (COLOR GOT MORE TRANSPARENT) AND BECAME SOFTER. THE PHYSICIAN WAS AFRAID, THAT THE SHEATH COULD TEAR OFF. HE NEEDED A LOT OF "MATERIAL" TO PULL THE SHEATH OUT. THE WAY FOR THIS SUCCESS WAS, TO INFLATE A .018 SABER BALLOON CATHETER IN THE NEAR OF THE TIP OF THE SHEATH AND PULL THE BALLOON AND THE SHEATH TOGETHER OUT OF THE PATIENT. THE PATIENT WAS NOT HARMED. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS STORED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE. THE SHEATH WAS IN PLACE FOR 15 MINUTES. THE SHEATH WAS NOT USED FOR ANY INFUSIONS OTHER THAN CONTRAST MEDIA. THE PROCEDURE WAS AN ENDOVASCULAR TREATMENT OF STENOSIS OF THE LEFT LEG. THE PROCEDURE USED A CROSSOVER FROM THE COMMON FEMORAL ARTERY INTO THE RIGHT EXTERNAL AND COMMON ILIAC ARTERY, ENDING IN THE LEFT COMMON ILIAC ARTERY ( WHICH WAS COVERED WITH AN OLD NITINOL STENT). THE VESSEL WAS SEVERELY CALCIFIED, MILDLY TORTUOUS, WITH MILD STENOSIS AND MODERATE BIFURCATION. THE FIRST TREATMENT WIT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14959637 ↗MalfunctionJun 11, 2019Material Frayed; Material Split, Cut or Torn; Material Frayed; Material Split, Cut or Torn
AS REPORTED, A BRITE TIP 7F 45CM STR SHEATH INTRODUCER WAS USED FOR PERCUTANEOUS CORONARY INTERVENTION (PCI), HOWEVER; THE TIP OF THE BRITE TIP SHEATH WAS BROKEN WHEN IT WAS INSERTED. ADDITIONAL INFORMATION WAS OBTAINED FROM THE PRODUCT ANALYSIS WHICH STATED, THAT THE BRITE TIP WAS OBSERVED TORN/SPLIT ON THE DISTAL AREA. THERE WERE NO REPORTED PATIENT INJURIES. THE DEVICE WAS REPLACED WITH ANOTHER BRITE TIP SHEATH AND IT WAS INSERTED WITHOUT ANY ISSUES. THE DEVICE WAS STORED WITH THE OTHER DEVICES. THE PRODUCT WAS STORED, HANDLED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICE. THERE WERE NO ANOMALIES NOTED PRIOR TO INSERTING THE DEVICE INTO THE PATIENT. THERE WAS NO DAMAGE NOTICED TO THE DEVICE PRIOR TO OPENING THE PACKAGE. THERE WAS NO DIFFICULTY REMOVING THE DEVICE FROM THE STERILE PACKAGING. THERE WAS NO UNUSUAL FORCE USED AT ANY TIME DURING THE PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8689251 ↗
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page