EXPEDIUM 179712745Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 x 7 x 45mm · Class 2 · Implant
All models of EXPEDIUM (291)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 19
- Deaths reported
- 0
- Injuries reported
- 17
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 19 adverse event reports that list this exact device (DI 10705034067902), received between Aug 28, 2017 and Feb 29, 2024 — classified as 17 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem8
- Break6
- Appropriate Device Problem Term/Code Not Available3
- Loose or Intermittent Connection2
- Entrapment of Device1
- Insufficient Device Problem Information1
- Material Split, Cut or Torn1
- Migration1
Patient problems
- No Code Available4
- Osteolysis4
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available3
- Pain3
- Failure of Implant2
- Impaired Healing2
- No Clinical Signs, Symptoms or Conditions2
- Foreign Body In Patient1
Recent adverse event reports
The 19 most recent of 19 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 29, 2024Break; Entrapment of Device; Break; Entrapment of Device
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON 25-DECEMBER-2021 AN UNKNOWN SURGERY FOR VERTEBRAL FRACTURE WAS PERFORMED. L1-L3 AND L4-S2 FUSION WAS PERFORMED DUE TO INJURY. AFTER THE INITIAL SURGERY, A REMOVAL SURGERY WAS PERFORMED ON (B)(6) 2024 BECAUSE OF THE CORRECTION LOSS FOUND ON L1-L3. L1-L3 FUSION WAS REMOVED. DURING THE REMOVAL SURGERY, IT WAS FOUND THAT THE SCREW IN QUESTION (L1 LEFT) BROKE AT THE BASE. THE SCREW WAS LEFT IN PLACE AND THE SURGERY WAS COMPLETED, AS THE SURGEON DETERMINED THAT THERE WAS NO PROBLEM WITH LEAVING THE BROKEN END INSIDE THE BODY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 18811240 ↗InjuryJan 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: WOUND INFECTION DEEP, WOUND INFECTION SUPERFICIAL. COMPLICATION TIME/INTERVENTION. POSTOPERATIVE (BEFORE DISCHARGE). THIS IS FOR DEPUY SYNTHES SPINE VIPER /OTHER AND EXPEDIUM POLYAXIAL PRODUCTS (SI POLYAXL SCREW 7 X 45MM (B)(4)).
Patient problems: Post Operative Wound Infection
MAUDE report 18454040 ↗InjuryJan 5, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (FCER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: IMPLANT FAILURE, INSTABILITY, NON-UNION COMPLICATION TIME/INTERVENTION REPEAT SURGERY THIS REPORT IS FOR ONE (1) SI POLYAXL SCREW 7 X 45MM THIS IS REPORT 3 OF 4 FOR COMPLAINT (B)(4).
Patient problems: Joint Laxity; Nonunion/Delayed-union Bone Fracture
MAUDE report 18451669 ↗InjuryJan 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: WOUND HEALING PROBLEM COMPLICATION TIME/INTERVENTION REPEAT SURGERY THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45MM. THIS IS REPORT 5 OF 5 FOR (B)(4).
Patient problems: Impaired Healing
MAUDE report 18451668 ↗InjuryJan 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: ADJACENT SEGMENT PATHOLOGY, NEUROCOMPRESSION. COMPLICATION TIME/INTERVENTION. REPEAT SURGERY. THIS IS FOR DEPUY SYNTHES SPINE EXPEDIUM /OTHER, MOSS MIAMI SI /OTHER AND EXPEDIUM POLYAXIAL PRODUCTS. THIS IS REPORT 1 OF 4 FOR COMPLAINT (B)(4).
Patient problems: Nerve Damage; Osteolysis
MAUDE report 18451187 ↗InjuryJan 4, 2024Migration; Migration
THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: ADJACENT SEGMENT PATHOLOGY, IMPLANT FAILURE, POSTOPERATIVE INFECTION DEEP, WOUND HEALING PROBLEM. COMPLICATION TIME/INTERVENTION. REPEAT SURGERY. THIS IS FOR DEPUY SYNTHES SPINE EXPEDIUM /OTHER AND EXPEDIUM POLYAXIAL AND VIPER CFX FENESTRATED PRODUCTS (SI POLYAXL SCREW 7 X 45MM FOR (B)(4).
Patient problems: Impaired Healing; Insufficient Information; Osteolysis; Unspecified Infection
MAUDE report 18443544 ↗InjuryJun 28, 2023Break; Break
IT WAS REPORTED THAT ON (B)(6) 2023, THERE WERE 2 SPINE SCREWS THAT WERE IN QUESTION. IT WAS FOUND THAT THE SCREWS WERE BROKEN. THE BROKEN HARDWARE WAS REMOVED FROM THE PATIENT. THIS REPORT INVOLVES ONE (1) EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45MM. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Failure of Implant
MAUDE report 17216323 ↗InjurySep 15, 2022Break; Break
DEVICE REPORT FROM COLOMBIA REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, A REVISION SURGERY WAS PERFORMED TO REMOVE OSTEOSYNTHESIS MATERIAL OF THE SPINE (EXPEDIUM 5.5 SYSTEM) BECAUSE ONE OF THE SCREWS IMPLANTED IN THE PATIENT BROKE. NO FURTHER INFORMATION WAS PROVIDED. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45MM. THIS IS REPORT 7 OF 9 FOR (B)(4).
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 15428051 ↗InjuryJun 24, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT A PRIMARY FUSION PROCEDURE (L3/4) ON (B)(6) 2011, AND LATER UNDERWENT A REVISION PROCEDURE AT A DIFFERENT HOSPITAL ON AN UNKNOWN DAY IN (B)(6) 2013. ON (B)(6) 2022, IT WAS REPORTED TO THE SALES REP THAT THE PATIENT WOULD UNDERGO A SECOND REVISION PROCEDURE TO REMOVE THE SCREWS AT L3/L4 AT THE HOSPITAL WHERE THE PRIMARY PROCEDURE WAS PERFORMED. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45MM. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 14803106 ↗InjuryJun 24, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT A PRIMARY FUSION PROCEDURE (L3/4) ON (B)(6) 2011, AND LATER UNDERWENT A REVISION PROCEDURE AT A DIFFERENT HOSPITAL ON AN UNKNOWN DAY IN (B)(6) 2013. ON (B)(6) 2022, IT WAS REPORTED TO THE SALES REP THAT THE PATIENT WOULD UNDERGO A SECOND REVISION PROCEDURE TO REMOVE THE SCREWS AT L3/L4 AT THE HOSPITAL WHERE THE PRIMARY PROCEDURE WAS PERFORMED. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 45 MM. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 14803075 ↗InjuryDec 8, 2021Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available; Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT, PROCEDURE WAS REVISED DUE TO BACK PAIN AND CONNECTION DEGENERATION. THIS REPORT IS FOR ONE (1) SI POLYAXL SCREW 7 X 45MM. THIS IS REPORT 1 OF 7 FOR COMPLAINT (B)(4).
Patient problems: Osteolysis; Pain
MAUDE report 12961907 ↗InjuryDec 8, 2021Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available; Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT, PROCEDURE WAS REVISED DUE TO BACK PAIN AND CONNECTION DEGENERATION. THIS REPORT IS FOR (1) SI POLYAXL SCREW 7 X 45MM. THIS IS REPORT 6 OF 7 FOR COMPLAINT (B)(4).
Patient problems: Osteolysis; Pain
MAUDE report 12961853 ↗MalfunctionNov 23, 2021Break; Break
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING A METAL REMOVAL SURGERY ON (B)(6) 2021, DUE TO BACK PAIN AND CONNECTION DEGENERATION. DURING THE PROCEDURE, A SCREW BROKE AS THE SCREWDRIVER WAS INSERTED INTO THE SCREW HEAD. SCREW HEAD AND SHAFT WERE BOTH REMOVED FROM THE PATIENT. THE SCREW WAS REPLACED. THERE IS NO ALLEGATION AGAINST THE SCREWDRIVER. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH AN UNKNOWN SURGERY DELAY. THIS REPORT IS FOR A SI POLYAXL SCREW 7 X 45MM. THIS IS REPORT 1 OF 1 FOR (B)(4) AND CAPTURES THE SCREW BREAKAGE. PATIENT¿S PAIN AND REVISION SURGERY IS CAPTURED UNDER (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12864928 ↗InjuryApr 12, 2019Break; Break
THE FOLLOWING WAS REPORTED: REVISION T4-PELVIS & BROKEN PEDICLE SCREWS: DR (B)(6), (B)(6) HOSPITAL, (B)(6) 2019. PT HAD A POSTERIOR SPINAL FUSION FOR SPINAL DEFORMITY, T4-PELVIS (3/11/16). IT WAS QUITE A SIGNIFICANT DEFORMITY. IT WAS NOTED THAT THE RODS BROKE AT L1 (2018) WHERE THERE IS A NON-UNION. THIS IS STAGE 1 OF 2. THE RODS WERE REMOVED ON BOTH SIDES, BROKEN SCREWS REMOVED, NEW SCREWS IMPLANTED AND THEN NEW COCR RODS. TWO NEW SFX CROSS CONNECTORS WERE ALSO USED.
Patient problems: No Code Available
MAUDE report 8510341 ↗InjuryApr 12, 2019Break; Break
THE FOLLOWING WAS REPORTED: REVISION T4-PELVIS & BROKEN PEDICLE SCREWS: DR (B)(6), NORTH (B)(6) HOSPITAL, (B)(6) 2019. PT HAD A POSTERIOR SPINAL FUSION FOR SPINAL DEFORMITY, T4-PELVIS ((B)(6) 2016). IT WAS QUITE A SIGNIFICANT DEFORMITY. IT WAS NOTED THAT THE RODS BROKE AT L1 (2018) WHERE THERE IS A NON-UNION. THIS IS STAGE 1 OF 2. THE RODS WERE REMOVED ON BOTH SIDES, BROKEN SCREWS REMOVED, NEW SCREWS IMPLANTED AND THEN NEW COCR RODS. TWO NEW SFX CROSS CONNECTORS WERE ALSO USED.
Patient problems: No Code Available
MAUDE report 8510285 ↗InjuryJan 14, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PLIF SURGERY WAS PERFORMED ON UNKNOWN DATE (ABOUT A YEAR AGO) TO FIX L4 WITH 7MM SCREW (P/N AND LOT NUMBER WERE UNKNOWN). AFTER ABOUT A YEAR FROM PRIMARY SURGERY, THE PATIENT¿S GOT ADJACENT SEGMENTAL DISEASES. THUS, THE REVISION SURGERY WAS PERFORMED ON (B)(6) 2017 TO REPLACE 7MM SCREW TO 8MM SCREW. NO FURTHER INFORMATION WAS PROVIDED BY THE HOSPITAL.
Patient problems: No Code Available
MAUDE report 8245027 ↗InjuryDec 21, 2018Loose or Intermittent Connection; Material Split, Cut or Torn; Loose or Intermittent Connection; Material Split, Cut or Torn
IT WAS REPORTED THAT ACCORDING TO A STATEMENT OF THE USER, THE SCREW COULD NOT FIXED WITH SCREWDRIVER. THUS, THE SCREW WAS NOT "MONO-AXIAL" BUT MOVING DURING THE DISPOSAL. THIS SHOULD HAVE CAUSED A SUBSEQUENT SCREWS MALPOSITION.
Patient problems: No Code Available; Pain
MAUDE report 8189097 ↗InjuryJan 9, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
"SPINAL STENOSIS OF THE LUMBAR SPINE WITH CLAUDICATIOSPINALIS SYMPTOMS, TWO-SIDED FOOT WEAKNESS AND KNEE EXTENSORS PALSY LEFT. THESE ISSUES SHOULD BE HANDLED AND REPAIRED A SPINAL FUSION OPERATION. A VENTRAL INTERPOSITIONS SPINAL FUSION AT L5/S1 WAS CARRIED OUT FOR THIS PURPOSE. A DEFECTIVE PEDICLE SCREW WAS USED DURING THE OPERATION (L4), WHICH CAUSED A HEMORRHAGE AND NERVE COMPRESSION. THE REVISION SURGERY OF THE (B)(6) 2017 THE PEDICLE SCREW IN L4 REMOVED, BECAUSE IT SHOWED A FISSURE OF THE PEDICLE. HEMATOMA AT L4 AND L5 (RIGHT) HAVE BEEN ADDRESSED. THE SCREW IN L3 (RIGHT) HAS BEEN THROUGH A 5 MM LONGER BOLT REPLACED.
Patient problems: Hematoma; Not Applicable
MAUDE report 7174685 ↗InjuryAug 28, 2017Loose or Intermittent Connection; Loose or Intermittent Connection
IMPLANT BROKE DURING INSERTION. COMPLAINT FORM SENT TO REP PER COMPLAINT FORM: WHEN PLACING THE REVISION SCREW, THE SCREWDRIVER MADE A POPPING NOISE WHICH WAS THE TIP OF THE DRIVER BREAKING. THE TIP WAS STUCK IN THE SCREW AND WE HAD TO ATTACH A ROD TO REMOVE. WE BROKE OFF THE HEAD OF THE SCREW ATTEMPTING TO REMOVE AND THEN USED A REVERSE THREADED REMOVAL TIP IN ORDER TO REMOVE THE SCREW SHAFT.
Patient problems: Failure of Implant
MAUDE report 6824422 ↗
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page