EXPEDIUM 179722150Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM POLYAXIAL SCREW 5.5 x 10 x 50mm · Class 2 · Implant
All models of EXPEDIUM (291)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034070162), received between Sep 5, 2018 and Sep 29, 2020 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Material Split, Cut or Torn1
Patient problems
- No Consequences Or Impact To Patient1
- Not Applicable1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2020Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2020, DURING A TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION) AT S1 TREATING SPONDYLOLISTHESIS, THE SCREWDRIVER TIP BROKE OFF DURING SCREW INSERTION. FRAGMENT(S) BECAME STUCK WITH THE SCREWS SHAFT. THE SURGEON REMOVED THE SCREW AND COMPLETED THE PROCEDURE WITH REPLACEMENTS. THERE WAS A, LESS THAN, 30-MINUTE SURGICAL DELAY. ALL THE FRAGMENTS WERE REMOVED WITH THE SCREW. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR ONE (1) EXPEDIUM SPINE SYSTEM POLYAXIAL SCREW 5.5 X 10 X 50MM THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10599455 ↗InjurySep 5, 2018Material Split, Cut or Torn; Material Split, Cut or Torn
ON (B)(6) 2018, THE TLIF SURGERY FOR LUMBAR SPONDYLOLISTHESIS WAS PERFORMED BY USING THE EXPEDIUM SYSTEM. THE FIXED SITE WAS L5 ¿ S1. DURING THE SURGERY, DUE TO AN EXCESSIVE INSERTING TORQUE, THE TIP OF THE DRIVER (279722400) GOT BROKEN AND THE BROKEN TIP WAS LEFT IN THE HEAD OF THE SCREW (EITHER 179722145 OR 179722150), WHICH RESULTED IN THE INSERTION FAILURE. THE SCREW IN QUESTION WAS EXTRACTED AND THEN A NEW SCREW WAS INSERTED. NO BROKEN PIECES WERE FOUND LEFT IN THE PATIENT¿S BODY UNDER THE X-RAY. THE SURGERY WAS SUCCESSFULLY COMPLETED WITH A 60-MINUTE DELAY, AND THERE WAS NO ADVERSE CONSEQUENCE TO THE PATIENT. THE SURGEON HAS REQUESTED US TO MAKE AN IN-DEPTH INVESTIGATION INCLUDING A POSSIBILITY OF METALLIC FATIGUE.
Patient problems: Not Applicable
MAUDE report 7847778 ↗
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page