EXPEDIUM 179732640Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 x 6 x 40mm · Class 2 · Implant
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705034073866), received between Mar 25, 2022 and Feb 14, 2024 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Compatibility Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Compatibility Problem1
- Device-Device Incompatibility1
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryFeb 14, 2024Migration; Migration
IT WAS REPORTED THE PATIENT HAD A SPINE CONSTRUCT IMPLANTED (B)(6) 2023 FROM T10 TO PELVIS. THE PATIENT WAS IMPLANTED WITH 2 EXPEDIUM RODS, AN UNKNOWN NUMBER VIPER AND EXPEDIUM SCREWS, AND TWO PELVIC SCREWS. PATIENT WAS EXPERIENCING PAIN AND HAD A FOLLOW UP (B)(6) 2023. DURING THE FOLLOW UP IMAGES IDENTIFIED 2 BROKEN RODS AND AN UNKNOWN NUMBER OF MIGRATED SCREWS. THE PATIENT WILL BE HAVING A REVISION SURGERY ON (B)(6) 2024. THIS REPORT IS FOR ONE (1) UNK - MONO/POLYAXIAL SCREWS: VIPER THIS IS REPORT 5 OF 6 FOR COMPLAINT (B)(4).
Patient problems: Pain
MAUDE report 18703372 ↗InjuryJan 12, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT AN UNKNOWN SURGERY FOR ADOLESCENT IDIOPATHIC SCOLIOSIS WAS COMPLETED ON (B)(6), 2022. AFTER THE SURGERY, ON (B)(6), 2023, AN INFECTION WAS CONFIRMED ON CONCAVE SIDE. REVISION SURGERY OCCURRED ON (B)(6), 2023. DURING THE REVISION, THE SET SCREWS ON T2·3·4·5 ON THE LEFT WERE REMOVED. THE ROD WHERE THE SET SCREWS WERE REMOVED WERE CUT BY THE T-SAW. THE RODS WERE REMOVED. FOUR OF THE UNIPLANAR SCREWS (5.0 DIAMETER 30MM LONG) ON THE LEFT T2-T5 WERE REMOVED. THE AFFECTED AREA WAS WASHED. THE HOOK WAS PLACED ON T2 (WIDE BLADE/THROAT 10). SIDE-SIDE CONNECTOR INSTALLED AT THE UPPER END OF T5. TITANIUM ROD CONNECTION WAS PERFORMED BETWEEN T2 AND T5. THE WOUND WAS CLOSED. THIS REPORT IS FOR ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 X 6 X 40MM FOR (B)(4). THIS COMPLAINT IS LINKED TO (B)(4).
Patient problems: Unspecified Infection
MAUDE report 18504212 ↗MalfunctionAug 18, 2023Compatibility Problem; Compatibility Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN COLUMBIA AS FOLLOWS: IT WAS REPORTED DURING A CORRECTION OF LUMBAR THORACIC DEFORMITY SURGERY ON (B)(6) 2023, THE SCREW DOES NOT SCREW INTO THE STUNNER. IT IS MARKED AN EXTENDED TABLET SCREW 6X40 OF THE EXPEDIUM. IT DID NOT FIT IN ANY OF THE SCREWDRIVERS. THIS IS FOR ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 X 6 X 40MM FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17572747 ↗MalfunctionMar 25, 2022Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022 DURING A PROCEDURE HAVING THE SCREW IN QUESTION, WAS NOT ABLE TO BE ATTACHED STRAIGHT TO THE SCREWDRIVER. AFTER REPLACING THE SCREW HAD NO FURTHER ISSUE IN CONNECTING TO THE SCREWDRIVER. PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT ANY SURGICAL DELAY. CONCOMITANT DEVICE REPORTED: UNKNOWN SCREWDRIVER (PART# UNKNOWN; LOT# UNKNOWN; QUANTITY: 1) THIS REPORT IS FOR ONE (1) SI POLYAXL EXT TAB 6 X 40MM. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13905071 ↗
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.