EXPEDIUM 179762045Recalls & reported problems

Medos International Sàrl · EXPEDIUM SPINE SYSTEM ROD 5.5 x 45mm · Class 2 · Implant

All models of EXPEDIUM (291)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10705034077314), received between Jul 22, 2022 and Nov 2, 2023 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Device-Device Incompatibility1

Patient problems

  • Osteolysis4
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 2, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THERE WAS POSTERIOR LUMBAR INTERBODY FUSION (L4/5) PERFORMED ON (B)(6) 2014. AFTER THE SURGERY, ASD OCCURRED. THE REOPERATION TO EXTEND FIXATION WILL BE PERFORMED ON (B)(6) 2023. THE EXP SINGLE INNER SETSCREW, MMSI ROD AND SFX 5.5 TRANSV CONN 49-66 MM IN QUESTION WILL BE REPLACED. 5.5 CANNULATED CORTICAL FIX SCREW 6X40MM AND CONC BULLET PARALLEL IN QUESTION WILL BE PRESERVED. THE EXTENSION SURGERY (L/S2) WILL BE PERFORMED WITH ALAR ILIAC, OLIF WILL BE PERFORMED FOR L2/3 AND L3/. THIS REPORT INVOLVES ONE (1) EXPEDIUM SPINE SYSTEM ROD 5.5 X 45MM. THIS IS REPORT 6 OF 10 FOR (B)(4). THIS PRODUCT COMPLAINT, (B)(4), IS RELATED TO (B)(4).

    Patient problems: Osteolysis

    MAUDE report 18055321 ↗
  • InjuryNov 2, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THERE WAS POSTERIOR LUMBAR INTERBODY FUSION (L4/5) PERFORMED ON (B)(6) 2014. AFTER THE SURGERY, ASD OCCURRED. THE REOPERATION TO EXTEND FIXATION WILL BE PERFORMED ON (B)(6) 2023. THE EXP SINGLE INNER SETSCREW, MMSI ROD AND SFX 5.5 TRANSV CONN 49-66 MM IN QUESTION WILL BE REPLACED. 5.5 CANNULATED CORTICAL FIX SCREW 6X40MM AND CONC BULLET PARALLEL IN QUESTION WILL BE PRESERVED. THE EXTENSION SURGERY (L/S2) WILL BE PERFORMED WITH ALAR ILIAC, OLIF WILL BE PERFORMED FOR L2/3 AND L3/. THIS REPORT INVOLVES ONE (1) EXPEDIUM SPINE SYSTEM ROD 5.5 X 45MM. THIS IS REPORT 7 OF 10 FOR (B)(4). THIS PRODUCT COMPLAINT, (B)(4), IS RELATED TO (B)(4).

    Patient problems: Osteolysis

    MAUDE report 18055319 ↗
  • InjuryMar 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT A SPINAL FUSION (L3/4) ON (B)(6) 2014. AFTER SURGERY, ADJACENT INTERVERTEBRAL DISORDER OCCURRED AT L2/3 AND L4/5. ON (B)(6), 2023, A REOPERATION WAS PERFORMED. IN THE REOPERATION, SET SCREWS AND RODS OF L3/4 WERE REMOVED, AND SCREWS WERE ADDED TO L2 AND L5. TLIF TREATING L2/3 AND TLIF TREATING L4/5 WERE DONE. THE PATIENT OUTCOME WAS REPORTED TO BE STABLE. THERE IS NO PROBLEM IN THE FUSION SITE TREATED IN THE INITIAL SURGERY IN 2024. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM ROD 5.5 X 45MM. THIS IS REPORT 5 OF 7 FOR (B)(4).

    Patient problems: Osteolysis

    MAUDE report 16644043 ↗
  • InjuryMar 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT A SPINAL FUSION (L3/4) ON (B)(6) 2014. AFTER SURGERY, ADJACENT INTERVERTEBRAL DISORDER OCCURRED AT L2/3 AND L4/5. ON (B)(6) 2023, A REOPERATION WAS PERFORMED. IN THE REOPERATION, SET SCREWS AND RODS OF L3/4 WERE REMOVED, AND SCREWS WERE ADDED TO L2 AND L5. TLIF TREATING L2/3 AND TLIF TREATING L4/5 WERE DONE. THE PATIENT OUTCOME WAS REPORTED TO BE STABLE. THERE IS NO PROBLEM IN THE FUSION SITE TREATED IN THE INITIAL SURGERY IN 2024. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM ROD 5.5 X 45MM. THIS IS REPORT 2 OF 7 FOR (B)(4).

    Patient problems: Osteolysis

    MAUDE report 16644038 ↗
  • MalfunctionJul 22, 2022Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THIS WAS A PLIF (L4-5) FOR TREATING SPONDYLOLISTHESIS ON (B)(6) 2022. THE 7.0X 40MM SCREW (UNK) CUT OUT DURING SCREW TIGHTENING (WIPER MOTION) WITH THE TORQUE WRENCH IN QUESTION. THE PROCEDURE WAS COMPLETED WITH A REPLACEMENT (7.0X 45MM SCREW) LESS THAN 30-MINUTE SURGICAL DELAY. HE COMMENTED THAT THE EVENT MIGHT HAVE BEEN TRIGGERED BY MALFUNCTIONING TORQUE-VALUE SETTING ON THE TORQUE WRENCH. IT WAS BECAUSE AN EXCESSIVE LOAD HAD BEEN UNEXPECTEDLY PUT ONTO THE SCREW. WHEN THE SURGEON WAS APPLYING THE REPLACEMENT, HE ALSO FELT STRONG LOAD EVEN BEFORE TORQUE CAME INTO ACTION. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR ONE (1) MMSI ROD, 5.5 X 45MM, TI. THIS IS REPORT 1 OF 3 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15085913 ↗

Other Orthosis, spondylolisthesis spinal fixation devices

All Orthosis, spondylolisthesis spinal fixation devices →