MOUNTAINEER 188311301Recalls & reported problems
Medos International Sàrl · MOUNTAINEER OCT SPINAL SYSTEM ADJUSTABLE WEDDING BAND 3.5 - 4.75mm · Class 2 · Implant
All models of MOUNTAINEER (51)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034156767), received between Mar 7, 2019 and Mar 7, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Disconnection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Disconnection1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 7, 2019Disconnection; Disconnection
IT WAS REPORTED THAT THE PRIMARY SURGERY WAS PERFORMED WITH ROBERT REID RRS SYSTEM (P/N AND LOT NUMBER WERE UNKNOWN) ON UNKNOWN DATE. ON (B)(6) 2019, THE EXTENSION SURGERY WAS PERFORMED WITH UNKNOWN REASON. DURING THE SURGERY, THE REPORTED DEVICE WAS TRIED TO CONNECT TO ALREADY IMPLANTED ROBERT REID RRS SYSTEM (P/N AND LOT NUMBER WERE UNKNOWN) AFTER HAMMERING. HOWEVER, IT WAS DIFFICULT TO CONNECT EVEN THOUGH THE SURGEON TRIED FOR ABOUT 30 MIN SUCH AS UNTIGHTENING THE SCREW. THEN, WHEN THE SURGEON REMOVED THE REPORTED CONNECTOR, IT WAS REPORTED THAT THE CONNECTOR HAD DISASSEMBLED. THE SURGERY WAS COMPLETED BY USING ALTERNATIVE DEVICE, AND EVENTUALLY THE CONNECTOR COULD CONNECT TO ROBERT REID RRS SYSTEM. THERE WAS LESS THAN 30-MIN. SURGICAL DELAY AND THERE WAS NO ADVERSE CONSEQUENCE TO THE PATIENT. NO FURTHER INFORMATION WAS PROVIDED BY THE HOSPITAL.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8399881 ↗
Other Orthosis, cervical pedicle screw spinal fixation devices
- INFINITY™ Occipitocervical Upper Thoracic System 3604026Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation2 recalls1 report
- CONNECTOR 79-2002Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604532Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604024Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- CONNECTOR 79-2003Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 360PT4022Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- OASYS 48551000Stryker Corporation · Orthosis, cervical pedicle screw spinal fixation45 reports
- SYMPHONY 1020-35-112Medos International Sàrl · Posterior cervical screw system6 deaths15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page