Skip to content

SUMMIT 274655100Recalls & reported problems

Depuy Spine, LLC · SUMMIT SI OCT SPINAL FIXATION SYSTEM ROD APPROXIMATOR · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705034193175), received between Aug 30, 2017 and Feb 25, 2022 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break4

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1
  • Not Applicable1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 25, 2022Break; Break

    IT WAS REPORTED THAT DURING A POSTERIOR SPINAL FUSION SURGERY ON (B)(6) 2022, A SMALL PIECE AT THE TIP OF THE ROD APPROXIMATOR BROKE OFF AS THE SURGEON WAS TRYING TO REDUCE A 3.5MM TI ROD AT L1-2. ALL FRAGMENTS WERE REMOVED FROM THE PATIENT. WHILE ATTEMPTING TO REMOVE A PEDICLE SCREW IN THE THORACIC SPINE, THE T20 SCREWDRIVER SHAFT STRIPPED. BOTH INSTRUMENTS WERE REMOVED FROM THE FIELD AND SENT TO DECON TO BE CLEANED AND SANITIZED. THE CASE WAS A THORACOLUMBAR REVISION, REMOVING SCREWS AT CERTAIN LEVELS AND EXTENDING UP. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO DELAY. THERE WERE NO PATIENT CONSEQUENCES. THIS REPORT IS FOR A KERRISON APPROXIMATOR. THIS IS REPORT 2 OF 2 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13599039 ↗
  • MalfunctionOct 31, 2019Break; Break

    STERILE PROCESSING DEPARTMENT NOTIFIED ME OF BROKEN INSTRUMENT (MISSING HALF ITS ¿JAW¿) IN TRAY. UNKNOWN HOW OR WHEN IT HAPPENED. REPLACEMENT URGENTLY NEEDED. CUSTOMER REFERENCE/PO/SERVICE: (B)(6). PATIENT STATUS/ OUTCOME / CONSEQUENCES: NO. WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: UNKNOWN. IS THE PATIENT PART OF A CLINICAL STUDY: UNKNOWN. IP (B)(4). DEVICE PROPERTY OF: NONE. DEVICE IN POSSESSION OF: REP. BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INFORMATION WILL BE MADE AVAILABLE, THE ADDITIONAL INFORMATION WILL BE SUBMITTED THROUGH CST. TRUE. THIS COMPLAINT INVOLVES ONE (1) DEVICE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9263113 ↗
  • MalfunctionNov 27, 2017Break; Break

    THE SURGEON WAS TRYING TO PLACE THE REDUCER UNDER THE HEAD OF THE POLYAXIAL SCREW AND WHILE HE WAS DOING THAT, TWISTED IT LEFT AND RIGHT TO MANEUVER IT UNDER THE HEAD OF THE SCREW AND THE TIP BROKE OFF.

    Patient problems: Not Applicable

    MAUDE report 7062376 ↗
  • MalfunctionAug 30, 2017Break; Break

    ATTEMPTING TO REDUCE THE ROD INTO THE MOUNTAINEER POLY SCREW HEAD, THE ROD REDUCTION PISTOL DEVICE WAS USED. THE FORCE APPLIED RESULTED IN THE "TIPS" OF THE DEVICE TO BREAK. THE TIPS WERE SMALL AND WERE UNABLE TO BE READILY RETRIEVED. A FINAL FLAT-PLATE X-RAY WAS TAKEN TO ENSURE THAT THEY WERE NOT LEFT BEHIND IN THE PATIENT. UPON X-RAY REVIEW, THE SURGEON AND RADIOLOGIST CONFIRMED NOT REMAINING PIECES REMAINED INSITU. THE SURGEON THEORIZED THAT THE SMALL LOOSE PIECES WERE MOST LIKELY SUCKED INTO THE SUCTION BANK.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6831626 ↗

FDA clearance and classification

The FDA regulates product code LXH (orthopedic manual surgical instrument) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the SUMMIT 274655100

Has the SUMMIT 274655100 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10705034193175), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the SUMMIT 274655100?

The FDA's MAUDE database lists 4 adverse event reports for this device, received between Aug 30, 2017 and Feb 25, 2022. In those reports, the most common specific device problem is “Break” (4); the most common patient problem is “Not Applicable” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the SUMMIT 274655100?

None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the SUMMIT 274655100 FDA approved?

Devices of this type (product code LXH) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Depuy Spine, LLC.

Who makes the SUMMIT 274655100, and is it still sold?

The FDA's device database lists Depuy Spine, LLC as the company responsible for it (brand SUMMIT, model 274655100). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page