EXPEDIUM 279722000Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM DUAL INNER INSERTER · Class 1
All models of EXPEDIUM (291)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10705034199283), received between Aug 23, 2023 and Nov 8, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 8, 2024Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT ON (B)(6) 2024, THE SURGEON WAS HAVING TROUBLE TIGHTENING THE SCREW, UPON INSPECTION THE TEETH ON THE DRIVER WAS SPLAYED AND NOT HOLDING THE SCREW. ANOTHER SCREWDRIVER WAS USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20641723 ↗MalfunctionAug 23, 2023Break; Break
IT WAS REPORTED THAT DURING A POSTERIOR SPINAL FUSION PROCEDURE ON (B)(6) 2023, THE DI INSERTER TIP BROKE OFF WHILE PLACING SET SCREWS. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO DELAY AND NO PATIENT CONSEQUENCE. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM DUAL INNER INSERTER. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17603537 ↗MalfunctionAug 23, 2023Break; Break
IT WAS REPORTED THAT DURING A POSTERIOR SPINAL FUSION PROCEDURE ON (B)(6) 2023, THE DI INSERTER TIP BROKE OFF WHILE PLACING SET SCREWS. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO DELAY AND NO PATIENT CONSEQUENCE. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM DUAL INNER INSERTER. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17603535 ↗
Other DRIVER, PROSTHESIS devices
- ATTUNE 2544-01-005Depuy (Ireland) · DRIVER, PROSTHESIS1,383 reports
- EXPEDIUM VERSE 299704230Medos International Sàrl · DRIVER, PROSTHESIS875 reports
- NA 9200-10-029Depuy (Ireland) · DRIVER, PROSTHESIS745 reports
- MOSS 279712600Depuy Spine, LLC · DRIVER, PROSTHESIS706 reports
- NA 2598-07-440Depuy (Ireland) · DRIVER, PROSTHESIS665 reports
- NA 2598-07-570Depuy (Ireland) · DRIVER, PROSTHESIS505 reports
- VIPER 286745550Depuy Spine, LLC · DRIVER, PROSTHESIS263 reports
- SUMMIT 2570-05-100Depuy (Ireland) · DRIVER, PROSTHESIS225 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page