VIPER 286735750Recalls & reported problems
Depuy Spine, LLC · VIPER 2 SYSTEM THREADED REDUCTION CAP 5.5 · Class 1
All models of VIPER (60)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10705034214689), received between Sep 29, 2022 and Oct 4, 2023 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Device Slipped” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Device Slipped4
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 4, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN COLUMBIA AS FOLLOWS: IT WAS REPORTED THAT ON SEPTEMBER 16 2023, THE SCREWDRIVER T20 DID NOT TAKE THE SCREWS OF THE SYSTEM VIPER2 PROPERLY. WHEN MAKING THE REDUCTION AND POSITIONING THE REDUCTION SLEEVES, THEY DO NOT SLIDE EASILY. THERE WAS NO INVOLVEMENT IN THE PATIENT. THIS COMPLAINT INVOLVES TWO (2) DEVICES. THIS REPORT IS FOR ONE (1) REDUCTION CAP. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17869215 ↗MalfunctionOct 21, 2022Device Slipped; Device Slipped
DEVICE REPORT FROM DEPUY SPINE REPORTS AN EVENT IN UNITED KINGDOM AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022 DURING VIPER 2 TRAUMA FIXATION, THE COLLARS ON THE VIPER 2 REDUCTION CAPS WERE LOOSE AND NOT SECURING TO THE SCREW EXTENSIONS MAKING REDUCTION TRICKIER FOR SURGEONS TO PERFORM AND ADDING TO THE PROCEDURE TIME. IT¿S ALSO MAKING THE SURGEON TO QUESTION WHETHER THEY ARE GETTING ENOUGH REDUCTION WITH THE CAPS BEING LOOSE. THERE WAS SURGICAL DELAY OF APPROXIMATE TEN (10) MINUTES DUE TO THE REPORTED EVENT. THE PROCEDURE WAS COMPLETED SAFELY AND THERE WAS NO PATIENT IMPACT. THERE WAS NO FURTHER MEDICAL INTERVENTION REQUIRED. THIS REPORT IS FOR ONE (1) REDUCTION CAP. THIS IS REPORT 3 OF 4 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15651258 ↗MalfunctionOct 21, 2022Device Slipped; Device Slipped
DEVICE REPORT FROM DEPUY SPINE REPORTS AN EVENT IN UNITED KINGDOM AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022 DURING VIPER 2 TRAUMA FIXATION, THE COLLARS ON THE VIPER 2 REDUCTION CAPS WERE LOOSE AND NOT SECURING TO THE SCREW EXTENSIONS MAKING REDUCTION TRICKIER FOR SURGEONS TO PERFORM AND ADDING TO THE PROCEDURE TIME. IT¿S ALSO MAKING THE SURGEON TO QUESTION WHETHER THEY ARE GETTING ENOUGH REDUCTION WITH THE CAPS BEING LOOSE. THERE WAS SURGICAL DELAY OF APPROXIMATE TEN (10) MINUTES DUE TO THE REPORTED EVENT. THE PROCEDURE WAS COMPLETED SAFELY AND THERE WAS NO PATIENT IMPACT. THERE WAS NO FURTHER MEDICAL INTERVENTION REQUIRED. THIS REPORT IS FOR ONE (1) REDUCTION CAP. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15651256 ↗MalfunctionOct 21, 2022Device Slipped; Device Slipped
DEVICE REPORT FROM DEPUY SPINE REPORTS AN EVENT IN UNITED KINGDOM AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022 DURING VIPER 2 TRAUMA FIXATION, THE COLLARS ON THE VIPER 2 REDUCTION CAPS WERE LOOSE AND NOT SECURING TO THE SCREW EXTENSIONS MAKING REDUCTION TRICKIER FOR SURGEONS TO PERFORM AND ADDING TO THE PROCEDURE TIME. IT¿S ALSO MAKING THE SURGEON TO QUESTION WHETHER THEY ARE GETTING ENOUGH REDUCTION WITH THE CAPS BEING LOOSE. THERE WAS SURGICAL DELAY OF APPROXIMATE TEN (10) MINUTES DUE TO THE REPORTED EVENT. THE PROCEDURE WAS COMPLETED SAFELY AND THERE WAS NO PATIENT IMPACT. THERE WAS NO FURTHER MEDICAL INTERVENTION REQUIRED. THIS REPORT IS FOR ONE (1) REDUCTION CAP. THIS IS REPORT 4 OF 4 FOR COMPLAINT: (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15651239 ↗MalfunctionSep 29, 2022Device Slipped; Device Slipped
IT WAS FURTHER REPORTED THAT NO OTHER MEDICAL INTERVENTION REQUIRED. THIS IS REPORT 1 OF 4 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15505923 ↗
FDA clearance and classification
The FDA regulates product code LXH (orthopedic manual surgical instrument) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the VIPER 286735750
Has the VIPER 286735750 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705034214689), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the VIPER 286735750?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Sep 29, 2022 and Oct 4, 2023. In those reports, the most common specific device problems are “Device Slipped” (4) and “Device-Device Incompatibility” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the VIPER 286735750?
None of the reports are classified as deaths, 0 as injuries and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the VIPER 286735750 FDA approved?
Devices of this type (product code LXH) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Depuy Spine, LLC.
Who makes the VIPER 286735750, and is it still sold?
The FDA's device database lists Depuy Spine, LLC as the company responsible for it (brand VIPER, model 286735750). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,989 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,199 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,163 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT852 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument821 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument559 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT492 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page