CONCORDE 292954602Recalls & reported problems
Depuy Spine, LLC · CONCORDE LS LATERAL INTERBODY INSTRUMENT SYSTEM UP ANGLE PITUITARY 6mm · Class 1
All models of CONCORDE (9)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034226347), received between Jun 25, 2021 and Jun 25, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 25, 2021Break; Break
DEVICE REPORT FROM SYNTHES EUROPE REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THE TIP OF THIS INSTRUMENT BROKE AS THE SURGEON WAS TRYING TO GRAB AND REMOVE A PIECE OF BONE. VARIOUS PLIERS, WRENCHES AND CUTTING DISCS WERE USED TO GRAB ONTO THE SCREW AND TRY TO UNSCREW IT. THE PROCEDURE TOOK 20-30 MIN TO REMOVE THE SCREW. ITEM 2929-54-602: THE TIP OF THIS INSTRUMENT BROKE AS THE SURGEON WAS TRYING TO GRAB AND REMOVE A PIECE OF BONE. ITEMS 2997-04-152 [X 2]: THIS ONE PART OF A 3-PART SCREW DRIVER ASSEMBLY. FOR SOME REASON, THE SCREWDRIVER WOULD DISASSEMBLE BY ITSELF WHEN A SCREW WAS LOADED AND TIGHTENED. I TRIED DIFFERENT PARTS FROM ANOTHER SET AND IT WAS DETERMINED THAT THESE WERE THE DEFECTIVE PARTS. ITEM 279712400: THE TIP OF THIS SCREWDRIVER BROKE AND GOT STUCK INSIDE THE SCREW HEAD. IT WAS A LARGE SCREW AND THE BONE WAS VERY HARD. THE SCREW WAS PARTIALLY IN THE BONE WHEN THE DRIVER BROKE. THE SCREW WAS EVENTUALLY REMOVED USING VARIOUS METHODS AND TOOLS. SURGERY GOT DELAYED BY AT LEAST 20-30 MIN. NO IMPACT ON PATIENT. CONCOMITANT DEVICE REPORTED: UNKNOWN SCREW (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKNOWN). UNKNOWN SHAFT (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKN
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12071147 ↗
FDA clearance and classification
The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CONCORDE 292954602
Has the CONCORDE 292954602 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705034226347), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CONCORDE 292954602?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 25, 2021. That report lists device problem “Break” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CONCORDE 292954602?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CONCORDE 292954602 FDA approved?
Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Depuy Spine, LLC.
Who makes the CONCORDE 292954602, and is it still sold?
The FDA's device database lists Depuy Spine, LLC as the company responsible for it (brand CONCORDE, model 292954602). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other RONGEUR devices
- SPOTLIGHT 292904201Depuy Spine, LLC · RONGEUR6 reports
- Symmetry RapidClean® 58-3200J-BDAspen Surgical Products, Inc. · Rongeur5 reports
- SPOTLIGHT 292904202Medos International Sàrl · RONGEUR5 reports
- NA 03.605.001Synthes GmbH · RONGEUR4 reports
- Symmetry Rapidclean® 58-3200-BDAspen Surgical Products, Inc. · Rongeur3 reports
- AESCULAP FF805RAesculap AG · RONGEUR3 reports
- Medicon 57.28.33Medicon eG. Chirurgiemechaniker-Genossenschaft · RONGEUR3 reports
- SPOTLIGHT 292902240Depuy Spine, LLC · RONGEUR3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page