SYMPHONY 1020-64-075Recalls & reported problems
Medos International Sàrl · SYMPHONY OCT SYSTEM PRE-CUT PRE-LORDOSED ROD TITANIUM ALLOY diameter4.0X75mm · Class 2 · Implant
All models of SYMPHONY (113)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 2
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034511887), received between Jan 14, 2021 and Jan 14, 2021 — classified as 2 deaths.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Unspecified Tissue Injury2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
DeathJan 14, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT (B)(6) 2020, DURING POSTERIOR CERVICAL FUSION SURGERY THE PATIENT DIED. THE DEPUY SYNTHES SPINE SYSTEM UTILIZED IN THIS PROCEDURE WAS THE SYMPHONY OCT SYSTEM. THE INSTRUMENTATION OF THE SYMPHONY SCREWS WAS UNEVENTFUL. THE SURGEON FIRST INSTRUMENTED C4-6 LATERAL MASSES, THEN C2 PARS, AND FINALLY T1 PEDICLES. ALL SCREW PLACEMENTS WERE CONFIRMED BY THE SURGEON WITH FLUOROSCOPY. THE SURGEON PROCEEDED TO PERFORM THE DECOMPRESSION WITH A C3-7 LAMINECTOMY. AFTERWARDS THE SURGEON CHANGED THE VECTOR OF THE PATIENTS HEAD TO RE-ALIGN THE SPINE AFTER DECOMPRESSION. APPROXIMATELY TEN (10) MINUTES AFTERWARDS HE BEGAN PREPARING TWO (2) 4.0MM RODS. PRIOR TO INSTRUMENTATION OF THE RODS, THE PATIENT BEGAN TO LOSE SENSORY NEUROMONITORING SIGNALS. APPROXIMATELY FIVE (5) MINUTES LATER THE PATIENT LOSES MOTOR SIGNALS AND LOW BLOOD PRESSURE. AT THIS MOMENT THERE IS AN URGENCY TO COMPLETE THE CONSTRUCT AND CLOSE THE PATIENT. THE SURGEON DECIDED TO USE 3.5MM RODS INSTEAD. ALL RODS AND SET SCREWS WERE IMPLANTED AND FINAL TIGHTENED AS INTENDED. THE PATIENT WENT INTO CARDIAC ARREST APPROXIMATELY 5 MINUTES INTO CLOSING. APPROXIMATELY 1 HOUR AFTERWARDS, TIME OF DEATH WAS ANNOUNCED. THERE W
Patient problems: Unspecified Tissue Injury
MAUDE report 11170850 ↗DeathJan 14, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT (B)(6) 2020, DURING POSTERIOR CERVICAL FUSION SURGERY THE PATIENT DIED. THE DEPUY SYNTHES SPINE SYSTEM UTILIZED IN THIS PROCEDURE WAS THE SYMPHONY OCT SYSTEM. THE INSTRUMENTATION OF THE SYMPHONY SCREWS WAS UNEVENTFUL. THE SURGEON FIRST INSTRUMENTED C4-6 LATERAL MASSES, THEN C2 PARS, AND FINALLY T1 PEDICLES. ALL SCREW PLACEMENTS WERE CONFIRMED BY THE SURGEON WITH FLUOROSCOPY. THE SURGEON PROCEEDED TO PERFORM THE DECOMPRESSION WITH A C3-7 LAMINECTOMY. AFTERWARDS THE SURGEON CHANGED THE VECTOR OF THE PATIENT¿S HEAD TO RE-ALIGN THE SPINE AFTER DECOMPRESSION. APPROXIMATELY TEN (10) MINUTES AFTERWARDS HE BEGAN PREPARING TWO (2) 4.0 MM RODS. PRIOR TO INSTRUMENTATION OF THE RODS, THE PATIENT BEGAN TO LOSE SENSORY NEUROMONITORING SIGNALS. APPROXIMATELY FIVE (5) MINUTES LATER THE PATIENT LOSES MOTOR SIGNALS AND LOW BLOOD PRESSURE. AT THIS MOMENT THERE IS AN URGENCY TO COMPLETE THE CONSTRUCT AND CLOSE THE PATIENT. THE SURGEON DECIDED TO USE 3.5 MM RODS INSTEAD. ALL RODS AND SET SCREWS WERE IMPLANTED AND FINAL TIGHTENED AS INTENDED. THE PATIENT WENT INTO CARDIAC ARREST APPROXIMATELY 5 MINUTES INTO CLOSING. APPROXIMATELY 1 HOUR AFTERWARDS, TIME OF DEATH WAS ANNOUNCED. THERE
Patient problems: Unspecified Tissue Injury
MAUDE report 11169920 ↗
Other Posterior cervical screw system devices
- INFINITY™ Occipitocervical Upper Thoracic System 3604026Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation2 recalls1 report
- CONNECTOR 79-2003Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 360PT4022Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- CONNECTOR 79-2002Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604532Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604024Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- OASYS 48551000Stryker Corporation · Orthosis, cervical pedicle screw spinal fixation45 reports
- YUKON OCT Spinal System 7601-05030VB Spine LLC · Orthosis, cervical pedicle screw spinal fixation15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page