- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034520148), received between Jul 24, 2023 and Sep 23, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 23, 2026Device-Device Incompatibility
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50868408 ↗MalfunctionJul 24, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6)2023, THE PATIENT UNDERWENT A POSTERIOR CERVICAL FUSION (C3-6). THE PROCEDURE PROCEEDED AS PLANNED, AND FINAL TIGHTENING OF A ROD WAS COMPLETED. AFTER THAT, THE SURGEON PLANNED TO SET A CROSS CONNECTOR ONTO THE SCREW AT C5. THE CROSS CONNECTOR SELECTED DID NOT FIT INTO THE SET SCREW AT ALL, SO A NEW CROSS CONNECTOR OF ONE SIZE SMALLER WAS SELECTED. THE SMALLER SIZED CONNECTOR WOULD ALSO NOT FIT ONTO THE SET SCREW, SO A BENDER WAS USED TO STRETCH THE CURVED PART OF THE CROSS CONNECTOR. THIS MADE THE CONNECTOR UNUSABLE. ANOTHER CROSS CONNECTOR OF THE SMALLER SIZE WAS PREPARED AND USED. THIS CONNECTOR WAS SET AT THE PROPER POSITION AND FINAL TIGHTENED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH UNDER 30 MINUTES OF DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A SYMPHONY OCT SYSTEM CROSSCONNECTOR HEAD TO HEAD 20 TO 30MM. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17380932 ↗
Other Posterior cervical screw system devices
- INFINITY™ Occipitocervical Upper Thoracic System 3604026Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation2 recalls1 report
- CONNECTOR 79-2003Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 360PT4022Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- CONNECTOR 79-2002Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604532Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604024Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- OASYS 48551000Stryker Corporation · Orthosis, cervical pedicle screw spinal fixation45 reports
- YUKON OCT Spinal System 7601-05030VB Spine LLC · Orthosis, cervical pedicle screw spinal fixation15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page