NA 03.611.031Recalls & reported problems
Synthes GmbH · 2.5MM SETSCREW EXTRACTOR · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034713847), received between Oct 2, 2018 and Oct 2, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 2, 2018Break; Break
IT WAS REPORTED THAT THE PATIENT, WITH ADJACENT LEVEL DISC DISEASE, UNDERWENT A SPINE REVISION PROCEDURE ON (B)(6) 2018, TO REMOVE SYNTHES USS (UNIVERSAL SPINAL SYSTEM) PEDICLE SCREWS AS THE ORIGINAL LEVEL L5 - S1 HAD FUSED. THE SURGEON REVISED THE PATIENT TO EXTEND FUSION ONE LEVEL ABOVE THE ALREADY FUSED L5-S1 LEVEL. WHILE THE SURGEON WAS ATTEMPTING TO BACK OUT THE PEDICLE SCREW WITH GENERAL SCREW REMOVAL INSTRUMENTS, THE TIP OF A 2.5MM SET SCREW EXTRACTOR BROKE OFF IN THE PEDICLE SCREW. THE SURGEON WAS ABLE TO REMOVE THE SCREW WITH VICE GRIPS WITHOUT ANY ADDITIONAL MEDICAL INTERVENTION BEING REQUIRED. THE SURGEON REMOVED THE 6.0MM TITANIUM SIDE-OPENING SCREW 45 MM (X2) AND THE 6.0MM TITANIUM SIDE-OPENING SCREWS 50MM (X2). THE EXPLANTED SCREWS WERE DISCARDED. ALL FRAGMENTS WERE SUCCESSFULLY REMOVED AND THE PATIENT OUTCOME WAS REPORTED TO BE "GOOD" AT THE END OF THE PROCEDURE. CONCOMITANT DEVICES REPORTED: 6.0MM TITANIUM SIDE-OPENING SCREW 45MM (PART# 498.645, LOT# UNKNOWN, QUANTITY# 2), 6.0 MM TITANIUM SIDE-OPENING SCREW 50MM (PART# 498.650, LOT# UNKNOWN, QUANTITY# 2). THIS REPORT CAPTURES INTRAOPERATIVE BREAKAGE OF SET SCREW EXTRACTOR. THIS REPORT IS FOR ONE (1) 2.5MM SET SCREW
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7927722 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page