NA 03.820.112Recalls & reported problems
Synthes GmbH · VERTEBRAL DISTRACTOR · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10705034731537), received between Dec 10, 2018 and Jul 29, 2025 — classified as 11 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem6
- Compatibility Problem2
- Break1
- Device Slipped1
- Mechanical Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 29, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT DURING A PROCEDURE, THE SURGEON TRIED TO DISTRACT THE VERTEBRAL BODY AND A PIECE OF THE DISTRACTOR BROKE. A NEW SET WAS NEEDED TO FINISH THE SURGERY. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22643612 ↗MalfunctionJul 8, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT ON AN UNKNOWN DATE THAT THERE WAS A BROKEN VERTEBRAL DISTRACTOR IN ONE OF SETS. THE MALFUNCTION WAS DISCOVERED AFTER SURGERY, NOT DURING SURGERY. AFTER PRESSING (SPREADING) THE VERTEBRAL BODY SPREADER, IT WOULD NOT BOUNCE BACK TO ITS ORIGINAL POSITION. THERE WAS NO INJURIES AND DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22437286 ↗MalfunctionSep 6, 2024Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT ON (B)(6) 2024 THE INSTRUMENT BROKE DURING A CASE. THERE WAS NO PATIENT IMPACT. THERE WAS NO SURGICAL DELAY. THIS REPORT IS FOR ONE (1) VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20159640 ↗MalfunctionMar 15, 2023Compatibility Problem; Compatibility Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SINGAPORE AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE SURGICAL TEAM NOTICED THE PRODISC C PARALLEL DISTRACTOR WAS STIFF AND UNABLE TO SPRING BACK TO ITS ORIGINAL RESTING POSITION DESPITE THE BACK LEVER BEING RELEASED. THIS DID NOT ALLOW THE INSTRUMENT TO FUNCTION AS INTENDED, SO IT WAS NOT USED DURING THE CASE. ANOTHER FUNCTIONAL PARALLEL DISTRACTOR WAS PROVIDED TO COMPLETE THE SURGERY. THIS REPORT IS FOR ONE (1) VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16549674 ↗MalfunctionJun 20, 2022Material Integrity Problem; Material Integrity Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN THE USA AS FOLLOWS: IT WAS REPORTED ON UNKNOWN DATE THAT, HE NEEDS A NEW CERVICAL, VERTEBRAL BODY DISTRACTOR TO BE SENT TO LOWTIDE ENTERPRISES, ALEXI IN SANTA CRUZ. ON THE CURRENT ONE, THE PIN HAS COME OUT OF. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. PROCEDURE AND PATIENT OUTCOME WERE UNKNOWN. THIS COMPLAINT INVOLVES ONE (1) DEVICE VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14745671 ↗MalfunctionMar 20, 2022Compatibility Problem; Compatibility Problem
IT WAS REPORTED THE VERTEBRAL DISTRACTOR WAS UN-ALIGNED AND WON'T LOCK. THIS REPORT IS FOR A VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13829301 ↗MalfunctionNov 24, 2021Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT ON AN UNKNOWN DATE, TWO VERTEBRAL BODY RETAINER AND ONE VERTEBRAL DISTRACTOR WERE BROKEN. IT IS UNKNOWN WHEN AND WHERE THE ISSUE WAS DISCOVERED. IT IS UNKNOWN IF THERE IS PATIENT NOR PROCEDURE INVOLVEMENT. THIS REPORT IS FOR ONE (1) VERTEBRAL DISTRACTOR. THIS IS REPORT 3 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12870842 ↗MalfunctionAug 6, 2021Break; Break
IT WAS REPORTED THAT ON AN UNKNOWN DATE, AFTER WASHING DURING INSPECTION FOR REASSEMBLY. IT WAS NOTED THAT THE END OF THE TIP OF THE VERTEBRAL DISTRACTOR IS BROKEN OFF. THERE WAS NO PATIENT INVOLVEMENT. THIS REPORT IS FOR ONE (1) VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12287589 ↗MalfunctionDec 7, 2020Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE ON NOVEMBER 10, 2020, THE TIP OF THE VERTEBRAL DISTRACTOR BROKE OFF. IT WAS RECOVERED AND TOOK OUT OF THE PATIENT. IT IS UNKNOWN IF THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WAS NO SURGICAL DELAY REPORTED. THE PATIENT OUTCOME WAS UNKNOWN. THIS REPORT IS FOR ONE (1) VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10960631 ↗MalfunctionOct 11, 2019Mechanical Problem; Mechanical Problem
IT WAS REPORTED THAT ON AN UNKNOWN DATE A VERTEBRAL DISTRACTOR PRODISC C SPRING IS FALLING OUT OF 1 OUT OF THE 2 ARMS OF THE DEVICE. THE CAUSE OF THE SPRING ISSUE IS UNKNOWN AS THE INSTRUMENT WAS BELIEVED TO BE PART OF ACCEPTABLE CENTINEL STOCK. THE DISTRIBUTING PARTNER IDENTIFIED THE ISSUE UPON RECEIPT OF THE INSTRUMENT SET. THERE WAS NO SURGICAL PROCEDURE INVOLVED, SCHEDULED, OR AFFECTED BY THE PROBLEM. THERE WAS NO PATIENT INVOLVEMENT. THIS COMPLAINT INVOLVES ONE (1) VERTEBRAL DISTRACTOR PRODISC C. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9178893 ↗MalfunctionDec 10, 2018Device Slipped; Device Slipped
IT WAS REPORTED THAT ON AN UNKNOWN DATE, A PRODISC C VERTEBRAL BODY DISTRACTOR WAS STICKING AND DIFFICULT TO ARTICULATE. THE SPRINGS NO LONGER FORCE THIS INSTRUMENT TO BE CLOSED. APPLICATION OF INSTRUMENT LUBRICANT HAS NOT BEEN ABLE TO IMPROVE THE CONDITION OF THE INSTRUMENT. THERE APPEARS TO BE NO PHYSICAL DAMAGE TO THE INSTRUMENT AND THE LOCKING MECHANISM IS FUNCTIONING AS EXPECTED. THERE WAS NO PROCEDURE OR PATIENT INVOLVEMENT. UPON MANUFACTURER RECEIPT AND INSPECTION OF THE DEVICE, IT WAS DETERMINED THAT A COMPONENT PART WAS LOOSE. THIS REPORT IS FOR A VERTEBRAL DISTRACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 8146286 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page