Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034741901), received between Feb 26, 2018 and Jul 26, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K072981); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Detachment of Device or Device Component1
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 26, 2018Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE PATIENT UNDERWENT A C4-C6 ANTERIOR CERVICAL FUSION ON (B)(6) 2018. DURING SURGERY, ONE (1) ZERO-P IMPLANT WAS SUCCESSFULLY PLACED IN THE C5-C6 SPACE. THE SURGEON THEN MOVED TO THE C4-C5 SPACE. THE SURGEON THEN PLACED THE DISTRACTOR PINS AT C4 AND C5 AND THEN PUT THE CERVICAL DISTRACTOR ON THE PINS AND PLACED DISTRACTION ON THE C4-C5 DISC SPACE. THE SURGEON THEN COMPLETED THE DISCECTOMY AND THEN DECIDED TO USE ONE (1) ZERO-P LORDOTIC IMPLANT. THE SURGEON PLACED THE IMPLANT ON THE AIMING DEVICE AND TRIED TO IMPACT THE IMPLANT IN C4-C5 SPACE. THE C4 DISTRACTION PIN AND DISTRACTOR WAS CLOSE TO THE C4-C5 DISC SPACE AND IMPEDED THE PLACEMENT OF THE ZERO-P DEVICE. WHILE TRYING TO PLACE THE DEVICE, THE ZERO-P SPACER CAME APART FROM THE IMPLANT. THE SURGEON WAS NOT COMFORTABLE WITH PUTTING THE IMPLANT BACK TOGETHER AND ASKED TO HAVE A NEW IMPLANT OF SAME SIZE AND TYPE. THE SURGEON THEN REMOVED THE DISTRACTOR AND DISTRACTION PINS. THE SURGEON THEN PLACED THE NEW ZERO-P IMPLANT SUCCESSFULLY. THE SURGEON THEN PLACED ALL THE SCREWS IN. THE SURGEON BELIEVED THAT THE DISTRACTION PIN LEVERED THE PLATE AWAY FROM THE SPACER DURING IMPLANTATION CAUSING IT TO SEPARATE. THE SUR
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7722053 ↗MalfunctionFeb 26, 2018Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT DURING A SPINAL FUSION PROCEDURE PERFORMED ON (B)(6) 2018, A ZERO-P IMPLANT 7MM HEIGHT SPLIT APART PRIOR TO FINAL IMPLANTATION IN THE PATIENT. THE IMPLANT WAS THEREFORE REMOVED FROM USE AND ANOTHER READILY AVAILABLE IMPLANT WAS USED INSTEAD. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7296270 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K072981. One submission often covers many models, so check the product and lot details in each record.
- Z-0104-2012 · Sep 23, 2011 · TerminatedSynthes Spine Zero-P Instruments and Implants. Zero-profile anterior cervical interbody fusion (ACIF) device.
- Z-1348-2009 · Feb 10, 2009 · TerminatedSynthes Zero-P StarDrive Screwdriver Shaft, T8, self-retaining, quick coupling, for use in spinal fusion surgery. Catalog # 03.617.902 Technique Guide.
Other Intervertebral fusion device with integrated fixation, cervical devices
- NA 03.617.902Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical103 reports
- NA 03.617.900Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical77 reports
- Divergence® Anterior Cervical Fusion System G6626525Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical75 reports
- Divergence® Anterior Cervical Fusion System G6626526Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical49 reports
- NA 03.617.905Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical29 reports
- NA 03.617.904Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical27 reports
- Divergence® Anterior Cervical Fusion System G6626746Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical21 reports
- NA 03.647.972Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page