SynFrame 387.344Recalls & reported problems
Synthes GmbH · SYNFRAME ANGLED ROD · Class 2
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10705034771106), received between Aug 7, 2020 and Jul 28, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Compatibility Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Compatibility Problem2
- Device-Device Incompatibility2
- Material Integrity Problem2
- Mechanical Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 28, 2025Mechanical Problem; Material Integrity Problem; Mechanical Problem; Material Integrity Problem
ADDITIONAL INFORMATION RECEIVED INDICATES THAT THESE WERE LOT NUMBERS OF THE PRODUCT:1050769-1 X21051599 X21649874 X2.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22632792 ↗MalfunctionJul 28, 2025Mechanical Problem; Material Integrity Problem; Mechanical Problem; Material Integrity Problem
IT WAS REPORTED THAT THE SURGEON WAS DOING A MAS DECOMPRESSION AND THE INSTRUMENT WAS FOUND LOOSE AND OLD, NEEDED REPLACING. THERE WAS NO DELAY TO SURGERY AND THE PATIENT WAS NOT AFFECTED. SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22632496 ↗MalfunctionJan 15, 2025Compatibility Problem; Compatibility Problem
IT WAS REPORTED THAT THE SURGEON USED THE SYNFRAME AND FOUND THAT ALL COMPONENTS ARE BECOMING OLD AND NEEDED TO BE REPLACED. THIS SYNFRAME IS OVER 20 YEARS OLD AND IS STARTING TO SHOW ITS AGE. THE CASING IS FALLING APART, PARTS PEELING OFF AND THE INSTRUMENT ARE BECOMING DIFFICULT TO ASSEMBLE. NO PATIENT WAS INVOLVED AS THIS OCCURED PRE-OP.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21158684 ↗MalfunctionJan 15, 2025Compatibility Problem; Compatibility Problem
IT WAS REPORTED THAT THE SURGEON USED THE SYNFRAME AND FOUND THAT ALL COMPONENTS ARE BECOMING OLD AND NEEDED TO BE REPLACED. THIS SYNFRAME IS OVER 20 YEARS OLD AND IS STARTING TO SHOW ITS AGE. THE CASING IS FALLING APART, PARTS PEELING OFF AND THE INSTRUMENT ARE BECOMING DIFFICULT TO ASSEMBLE. NO PATIENT WAS INVOLVED AS THIS OCCURED PRE-OP.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21158673 ↗MalfunctionAug 7, 2020Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED ALL PARTS OF A SPINE KIT THAT NEED TO BE TIGHTENED OR LOCKED NEED TO BE LUBRICATED. THIS WAS NOTED DURING AN ANTERIOR LUMBAR INTERBODY FUSION (ALIF) CASE ON (B)(6) 2020 WHERE THERE WERE DEVICE INTERACTION ISSUES. ADDITIONALLY, 2 BLUE CLAMPS HAVE BEEN TAGGED BECAUSE THEY WERE NOT GRIPPING TO THE O-RING PROPERLY. CONCOMITANT DEVICE REPORTED: UNKNOWN O-RING (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY UNKNOWN). THIS IS REPORT 8 OF 10 FOR (B)(4). THIS COMPLAINT IS LINKED TO (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10381892 ↗MalfunctionAug 7, 2020Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED ALL PARTS OF A SPINE KIT THAT NEED TO BE TIGHTENED OR LOCKED NEED TO BE LUBRICATED. THIS WAS NOTED DURING AN ANTERIOR LUMBAR INTERBODY FUSION (ALIF) CASE ON (B)(6) 2020 WHERE THERE WERE DEVICE INTERACTION ISSUES. ADDITIONALLY, 2 BLUE CLAMPS HAVE BEEN TAGGED BECAUSE THEY WERE NOT GRIPPING TO THE O-RING PROPERLY. CONCOMITANT DEVICE REPORTED: UNKNOWN O-RING (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY UNKNOWN). THIS IS REPORT 9 OF 10 FOR (B)(4). THIS COMPLAINT IS LINKED TO (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10381864 ↗
Other Lamp, operating-room devices
- iLED7 Surgical Light 4068110Baxter Medical Systems GmbH + Co. KG · Lamp, operating-room1 recall3 reports
- TL 5000/3000 – Surgical Light 4038310Baxter Medical Systems GmbH + Co. KG · Lamp, operating-room1 recall1 report
- iLED7 Surgical Light 4068410Baxter Medical Systems GmbH + Co. KG · Lamp, operating-room1 recall0 reports
- SynFrame 387.345Synthes GmbH · Lamp, operating-room12 reports
- iLED 4068210Baxter Medical Systems GmbH + Co. KG · Lamp, operating-room12 reports
- SynFrame 387.343Synthes GmbH · Lamp, operating-room9 reports
- SynFrame 387.338Synthes GmbH · Lamp, operating-room9 reports
- iLED 4068310Baxter Medical Systems GmbH + Co. KG · Lamp, operating-room8 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.