USS 498.813Recalls & reported problems
Synthes GmbH · TI USS PREASSEMBLED TRANSCONNECTOR CLAMP · Class 2 · Implant
All models of USS (14)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034791753), received between Oct 15, 2019 and Oct 15, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Material Twisted/Bent1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 15, 2019Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING A LUMBAR ARTHRODESIS PROCEDURE THE SURGEON WAS UNABLE TO ADJUST THE TWO (2) LOCKING CAPS AND COULD NOT INSERT THE TWO (2) CROSS-LINK CLAMPS. THE PATIENT STATUS IS STABLE. CONCOMITANT DEVICE REPORTED: UNKNOWN ROD (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1), SCREWDRIVER SHAFT 3.5 WITH HEXAGONAL QUICK COUPLING 6.0MM FOR CLICK X (PART # 388.079, LOT # UNKNOWN, QUANTITY 1), SCREWDRIVER SHAFT 3.5 MM LONG WITH HEXAGONAL QUICK COUPLING 6.0 M, FOR CLICK X (PART # 388.329, LOT # UNKNOWN, QUANTITY 1), CLICKX LOCK CAP (PART # 498.570, LOT # UNKNOWN, QUANTITY 1), CLICKX LOCK CAP (PART # 04.606.000, LOT # UNKNOWN, QUANTITY 5). THIS REPORT IS FOR ONE (1) CROSS-LINK-CLAMP F/R Ø6 PREASSEMBLE TAN DB. THIS IS REPORT 1 OF 4 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9192811 ↗
FDA clearance and classification
The FDA regulates product code MNH (orthosis, spondylolisthesis spinal fixation) under 21 CFR 888.3070 as a Class II device. 21 CFR 888.3070 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the USS 498.813
Has the USS 498.813 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705034791753), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the USS 498.813?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 15, 2019. That report lists device problems “Device-Device Incompatibility” (1) and “Material Twisted/Bent” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the USS 498.813?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the USS 498.813 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the USS 498.813, and is it still sold?
The FDA's device database lists Synthes GmbH as the company responsible for it (brand USS, model 498.813). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page