USS 498.813Recalls & reported problems
Synthes GmbH · TI USS PREASSEMBLED TRANSCONNECTOR CLAMP · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034791753), received between Oct 15, 2019 and Oct 15, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Material Twisted/Bent1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 15, 2019Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING A LUMBAR ARTHRODESIS PROCEDURE THE SURGEON WAS UNABLE TO ADJUST THE TWO (2) LOCKING CAPS AND COULD NOT INSERT THE TWO (2) CROSS-LINK CLAMPS. THE PATIENT STATUS IS STABLE. CONCOMITANT DEVICE REPORTED: UNKNOWN ROD (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1), SCREWDRIVER SHAFT 3.5 WITH HEXAGONAL QUICK COUPLING 6.0MM FOR CLICK X (PART # 388.079, LOT # UNKNOWN, QUANTITY 1), SCREWDRIVER SHAFT 3.5 MM LONG WITH HEXAGONAL QUICK COUPLING 6.0 M, FOR CLICK X (PART # 388.329, LOT # UNKNOWN, QUANTITY 1), CLICKX LOCK CAP (PART # 498.570, LOT # UNKNOWN, QUANTITY 1), CLICKX LOCK CAP (PART # 04.606.000, LOT # UNKNOWN, QUANTITY 5). THIS REPORT IS FOR ONE (1) CROSS-LINK-CLAMP F/R Ø6 PREASSEMBLE TAN DB. THIS IS REPORT 1 OF 4 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9192811 ↗
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.