SYNFIX Evolution 08.815.122SRecalls & reported problems
Synthes GmbH · SYNFIX® EVOLUTION SPACER SMALL/12MM HEIGHT/14°-STERILE · Class 2 · Implant
All models of SYNFIX Evolution (21)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034815183), received between May 16, 2018 and May 16, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Operates Differently Than Expected1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 16, 2018Device Operates Differently Than Expected; Device Operates Differently Than Expected
IT WAS REPORTED ON (B)(6) 2018, PATIENT UNDERWENT INITIAL SURGERY, AN ANTERIOR LUMBER INTERBODY FUSION (ALIF), WITH NON-SYNTHES POSTERIOR HARDWARE, TWO (2) SYNFIX EVOLUTION CAGES, AND EIGHT (8) 20MM SCREWS DUE TO PATIENT HAD RARE CASE SPONDYLOPTOSIS. THE PATIENT UNDERWENT A REVISION ON (B)(6) 2018 FOR A FULL CORPECTOMY THAT WASN'T COMPLETED DURING THE INITIAL SURGERY, NOT IMPLANTED RELATED. THE SURGEON HAD SOME SIGNIFICANT CHALLENGES DURING THE REVISION. INITIALLY HE ATTEMPTED TO USE THE STRAIGHT DRIVER WITH THE AIMING DEVICE LOADED ON THE IMPLANT. THIS RESULTED IN THE TIP BEING TORQUED OUT. HE THEN TRIED ANOTHER STRAIGHT DRIVER WITHOUT THE AIMING DEVICE LOADED AND WAS UNABLE TO LOOSEN THE SCREW. HE THEN PLACED THE AIMING DEVICE BACK ONTO THE IMPLANT AND ATTEMPTED TO USE THE ARTICULATING DRIVERS. AGAIN, HE WAS UNABLE TO LOOSEN THE SCREWS AND ENDED UP SHEERING THE TIPS OF TWO DRIVERS. AT ONE POINT THE SURGEON USED A MALLET AND ATTEMPTED TO TURN AND HAMMER ON THE STRAIGHT DRIVER SIMULTANEOUSLY WHICH DIDN¿T BREAK THE SEAL EITHER. ULTIMATELY, HE HAD TO USE A METAL CUTTING BURR TO SHAVE/REMOVE THE TIPS OF THE SCREWS. THIS RESULTED IN METAL FRAGMENTS BEING DISPLACED AND THE USE OF KY JEL
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7519885 ↗
Other Intervertebral fusion device with integrated fixation, lumbar devices
- PIVOX™ Oblique Lateral Spinal System 2161001Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, lumbar182 reports
- IdentiTi 232-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall8 reports
- IdentiTi 232-10-85-250Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall5 reports
- IdentiTi 132-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall3 reports
- IdentiTi 232-10-85-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall2 reports
- MectaLIF Anterior 03.30.301Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall2 reports
- IdentiTi 232-11-90-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall1 report
- MectaLIF Anterior 03.30.300Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page