LF 847002Recalls & reported problems

Liebel-Flarsheim Company LLC · OptiOne Single-Head CT Contrast Delivery System · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10746190002758), received between Apr 24, 2024 and Apr 24, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Infusion or Flow Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Infusion or Flow Problem1

Patient problems

  • Extravasation1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 24, 2024Infusion or Flow Problem; Infusion or Flow Problem

    THIS CASE WAS REPORTED BY A FACILITY IN BRASILIA, BRAZIL ON (B)(6) 2024. REPORTER INFORMED THAT "IT'S INFUSING IT WRONG, EXTRAVASATING CONTRAST."I REQUEST PREVENTIVE MAINTENANCE AND FUNCTIONAL VERIFICATION OF THE EQUIPMENT, IN ONE WEEK THERE WERE 4 OVERFLOWS. ADDITIONAL INFORMATION RECEIVED ON 29-MAR-2024: PATIENT WAS CONNECTED. PATIENT HAD EXTRAVASATION. WAITING FOR ADDITIONAL INFORMATION IN REGARDS TO PATIENT. ADDITIONAL INFORMATION RECEIVED ON 01-APR-2024: THERE WAS NO REPORT OF AN ERROR MESSAGE ON THE INJECTOR. -WHAT WAS THE FLOW RATE AND THE PRESSURE LIMIT THEY PROGRAMMED AND THE ACTUAL FLOW RATE THEY SAW DURING THE PROCEDURE? THE FLOW RATE NORMALLY USED HAS NOT BEEN GREATER THAN 3.5ML/S -WHAT WAS THE OUTCOME OF THE 4 PATIENTS? DID THE 4 OF THEM HAVE EXTRAVASATION OR ONLY THE LAST ONE ? THERE WERE 3 CASES REPORTED. NONEOF THE 3 EXAMS WERE COMPLETED. 2 I HAVE ALREADY DISCHARGED; 1 I WILL STILL FOLLOW UP UNTIL 29 MAR 2024. SO FAR, NONE HAVE HAD ANY INJURIES. FOLLOW-UPS WERE CARRIED OUT BY TELEPHONE; DISCHARGES WERE GIVEN AFTER PATIENTS REPORTED BEING ASYMPTOMATIC. -IS IT POSSIBLE TO HAVE THE NAME OF CONTRAST MEDIA USED IF IT IS A GUERBET PRODUCT ? HENETIX, BATCH: 23WC369B, WAS M

    Patient problems: Extravasation

    MAUDE report 19173637 ↗

Other Injector, Contrast Medium, Automatic devices

All Injector, Contrast Medium, Automatic devices →