Bausch + Lomb SE5423WVBRecalls & reported problems

Bausch & Lomb Incorporated · 23 ga. Bi-Blade Vitreous Cutter Posterior Wide-Field Stellaris Elite Pack · Class 2

Adverse event reports
6
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10757770059932), received between Jul 5, 2022 and May 5, 2026 — classified as 2 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Failure to Cut” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Cut4
  • Adverse Event Without Identified Device or Use Problem1
  • Fluid/Blood Leak1
  • Particulates1
  • Product Quality Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Vitreous Loss1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 5, 2026Failure to Cut

    THE USER FACILITY IN ITALY REPORTED THE VITRECTOR WAS ASPIRATING BUT WAS UNABLE TO CUT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25081455 ↗
  • InjuryJan 27, 2026Failure to Cut; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY A USER FACILITY IN SPAIN THAT THE VITREOUS WAS RUPTURED IN THE OPERATING ROOM. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Vitreous Loss

    MAUDE report 24193043 ↗
  • MalfunctionMay 12, 2025Failure to Cut; Failure to Cut

    A USER FACILITY IN CHINA WAS USING THE VITRECTOMY CUTTER WHICH WAS RATTLING AND NOT CUTTING BUT CONTINUED TO ASPIRATE. THERE WAS PATIENT CONTACT BUT NO EFFECT THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22003998 ↗
  • MalfunctionApr 23, 2025Failure to Cut; Failure to Cut

    THE USER FACILITY REPORTED THAT DURING SURGERY THE VITRECTOMY CUTTER WAS FOUND TO HAVE A STRANGE NOISE AND WAS NOT CUTTING. ASPIRATION CONTINUED AFTER IT STOPPED CUTTING. THE SURGERY WAS EXTENDED, BUT THE DELAY TIME WAS NOT PROVIDED. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21893790 ↗
  • MalfunctionJul 16, 2024Particulates; Particulates

    A USER FACILITY REPORTED THAT A PIECE OF METAL WAS FOUND IN THE PATIENTS EYE AFTER SURGERY. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT NOT RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19753555 ↗
  • InjuryJul 5, 2022Fluid/Blood Leak; Product Quality Problem; Fluid/Blood Leak; Product Quality Problem

    THE USER FACILITY IN (B)(6) REPORTED THE VALVES ON THE TROCARS DID NOT CLOSE PROPERLY. WHEN THE INSTRUMENT WAS REMOVED, THE TROCARS ALSO CAME OUT AND HAD TO BE PLACED AGAIN. THIS OCCURRED ON THREE OCCASIONS FOR THE SAME SURGERY. SERUM ALSO LEAKED THROUGH THE VALVES. THE SURGERIES WERE PROLONGED FOR APPROXIMATELY 15 MINUTES AND SUTURES WERE NOT NECESSARY FOR ALL SURGERIES BUT WERE FREQUENTLY USED. ALL SURGERIES WERE COMPLETED SUCCESSFULLY WITH NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14915791 ↗

Other Instrument, Vitreous Aspiration And Cutting, Ac-Powered devices

All Instrument, Vitreous Aspiration And Cutting, Ac-Powered devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.