ARROW IPN036349Recalls & reported problems
Teleflex Incorporated · ARROWg+ard Blue(R) MAC(TM) Two-Lumen Central Venous Access Kit for use with 7.5 - 8 Fr. Catheters · Class 2
All models of ARROW (1494)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 1
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10801902141122), received between Mar 10, 2020 and Mar 10, 2020 — classified as 1 death, 2 injuries.
The most frequently reported specific device problem is “Inadequacy of Device Shape and/or Size” (1 report).
10 other recalls cover devices cleared under the same FDA submission (K011761); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Inadequacy of Device Shape and/or Size1
- Inadequate Instructions for Healthcare Professional1
- Malposition of Device1
- Material Protrusion/Extrusion1
Patient problems
- Injury3
- Stroke/CVA2
- Death1
- No Code Available1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 10, 2020Material Protrusion/Extrusion
AN ARROWG+ARD BLUE MAC CATHETER WAS INADVERTENTLY PLACED INTO THE RIGHT CAROTID ARTERY DURING ATTEMPTED INTERNAL JUGULAR VEIN CANNULATION. THE RESULTING ARTERIAL INJURY REQUIRED SURGICAL REPAIR, AND THE PT SUBSEQUENTLY SUFFERED AN EMBOLIC STROKE. OUR SUBSEQUENT STIMULATION OF THE DEVICE INSERTION DEMONSTRATED THAT THE DILATOR CAN PUNCTURE THE POSTERIOR VESSEL WALL, POTENTIALLY DAMAGING ADJACENT STRUCTURES, WHEN THE GUIDEWIRE IS NOT INSERTED TO SUFFICIENT DEPTH. UNDER THESE CONDITIONS, THE SHARP TIP OF THE DILATOR IS NOT PROTECTED BY PROTRUDING GUIDEWIRE AND CAN DIRECTLY CONTACT AND PENETRATE THE POSTERIOR VESSEL WALL. WITHOUT SUFFICIENT WIRE TO GUIDE IT, THE DILATOR FOLLOWS A STRAIGHT TRAJECTORY FROM THE SKIN SURFACE INCREASING THE LIKELIHOOD THAT IT WILL PENETRATE THE POSTERIOR VESSEL WALL, RATHER THAN FOLLOWING THE VESSEL LUMEN. THE MFR DOES NOT PROVIDE INSTRUCTIONS ON APPROPRIATE GUIDEWIRE INSERTION DEPTH, AND THE GUIDEWIRE IS NOT MARKED TO INDICATE APPROPRIATE INSERTION DEPTH. THE 45CM GUIDEWIRE PROVIDED IN THE KIT MAY CONTRIBUTE TO THE RISK OF THIS COMPLICATION; A LONGER (60CM) GUIDEWIRE IS PROVIDED IN A TRIPLE-LUMEN CATHETER BY THE SAME MFR. THE 45CM GUIDEWIRE DOES NOT PROVID
Patient problems: Injury; Stroke/CVA
MAUDE report 9818334 ↗InjuryMar 10, 2020Inadequate Instructions for Healthcare Professional; Inadequacy of Device Shape and/or Size
DURING AN ATTEMPTED FEMORAL VEIN CANNULATION WITH AN ARROWG+ARD BLUE MAC CATHETER, THE FEMORAL ARTERY WAS DAMAGED. THE PT'S LEG REQUIRED SURGICAL AMPUTATION AS A COMPLICATION OF THE VASCULAR INJURY. OUR SUBSEQUENT STIMULATION OF THE DEVICE INSERTION DEMONSTRATED THAT THE DILATOR CAN PUNCTURE THE POSTERIOR VESSEL WALL, POTENTIALLY DAMAGING ADJACENT STRUCTURES, WHEN THE GUIDEWIRE IS NOT INSERTED TO SUFFICIENT DEPTH. UNDER THESE CONDITIONS, THE SHARP TIP OF THE DILATOR IS NOT PROTECTED BY PROTRUDING GUIDEWIRE AND CAN DIRECTLY CONTACT AND PENETRATE THE POSTERIOR VESSEL WALL. WITHOUT SUFFICIENT WIRE TO GUIDE IT, THE DILATOR FOLLOWS A STRAIGHT TRAJECTORY FROM THE SKIN SURFACE INCREASING THE LIKELIHOOD THAT IT WILL PENETRATE THE POSTERIOR VESSEL WALL, RATHER THAN FOLLOWING THE VESSEL LUMEN. THE MFR DOES NOT PROVIDE INSTRUCTIONS ON APPROPRIATE GUIDEWIRE INSERTION DEPTH, AND THE GUIDEWIRE IS NOT MARKED TO INDICATE APPROPRIATE INSERTION DEPTH. THE 45CM GUIDEWIRE PROVIDED IN THE KIT MAY CONTRIBUTE TO THE RISK OF THIS COMPLICATION; A LONGER (60CM) GUIDEWIRE IS PROVIDED IN A TRIPLE-LUMEN CATHETER BY THE SAME MFR. THE 45CM GUIDEWIRE DOES NOT PROVIDE SUFFICIENT LENGTH WITHIN THE TARGET VESSEL IF
Patient problems: Injury; No Code Available
MAUDE report 9818302 ↗DeathMar 10, 2020Malposition of Device
AN ARROWG+ARD BLUE MAC CATHETER WAS INADVERTENTLY PLACED INTO THE JUNCTION OF THE RIGHT CAROTID ARTERY AND SUBCLAVIAN ARTERY DURING ATTEMPTED INTERNAL JUGULAR VEIN CANNULATION. THE RESULTING ARTERIAL INJURY REQUIRED SURGICAL REPAIR AND THE PT SUBSEQUENTLY SUFFERED AN EMBOLIC STROKE, FOLLOWED BY DEATH. OUR SUBSEQUENT SIMULATION OF THE DEVICE INSERTION DEMONSTRATED THAT THE DILATOR CAN PUNCTURE THE POSTERIOR VESSEL WALL, POTENTIALLY DAMAGING ADJACENT STRUCTURES, WHEN THE GUIDEWIRE IS NOT INSERTED TO SUFFICIENT DEPTH. UNDER THESE CONDITIONS, THE SHARP TIP OF THE DILATOR IS NOT PROTECTED BY PROTRUDING GUIDEWIRE AND CAN DIRECTLY CONTACT AND PENETRATE THE POSTERIOR VESSEL WALL. WITHOUT SUFFICIENT WIRE TO GUIDE IT, THE DILATOR FOLLOWS A STRAIGHT TRAJECTORY FROM THE SKIN SURFACE, INCREASING THE LIKELIHOOD THAT IT WILL PENETRATE THE POSTERIOR VESSEL WALL, RATHER THAN FOLLOWING THE VESSEL LUMEN. THE MFR DOES NOT PROVIDE INSTRUCTIONS ON APPROPRIATE GUIDEWIRE INSERTION DEPTH, THE 45CM GUIDEWIRE PROVIDED IN THE KIT MAY CONTRIBUTE TO THE RISK OF THIS COMPLICATION, A LONGER (60CM) GUIDEWIRE IS PROVIDED IN A TRIPLE-LUME CATHETER BY THE SAME MFR. THE 45CM GUIDEWIRE DOES NOT PROVIDE SUFFICIENT LENGT
Patient problems: Death; Injury; Stroke/CVA
MAUDE report 9817849 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K011761. One submission often covers many models, so check the product and lot details in each record.
- Z-2385-2026 · Apr 21, 2026 · Open, ClassifiedDescription/REF: ACCESS TRAY/GU-04020; PSI KIT: 8.5 FR/AK-09803-CDC; PSI KIT: 9 FR/AK-09903-CDC; PSI KIT: 8.5 FR X 4 IN (10 CM)/ASK-09810-PCMH1; PSI KIT: 9 FR X 10 CM/ASK-09903-KH;
- Z-2555-2019 · Aug 6, 2019 · Terminated8.5 Fr. X 10 cm ARROW+gard Blue PSI Kit Cath-Gard for use with 7.5 - 8 Fr.Catheters Product Code: CDC-29803-1A - Product Usage: The MACTM Two-Lumen Central Venous Access Device wit
- Z-1983-2018 · Apr 11, 2018 · TerminatedMAC(TM) Two-Lumen Central Venous Access Kit with ARROWg+ard Blue(R) Access Device, Integral Hemostasis Valve and Sharps Safety Features for use with 7.5 - 8 Fr. Catheters; Product
- Z-1324-2018 · Dec 22, 2017 · Terminated(1) ARROWg+ard Blue(R) MAC(TM) Two-Lumen Central Venous Access Kit for use with 7.5 - 8 Fr. Catheters, Product Number: ASK-21142-RH; (2) Arrowg+ard Blue(R) MAC(TM) Two-Lumen Centra
- Z-1002-2018 · Nov 27, 2017 · TerminatedARROWg+ard Blue Product Usage: The Arrow CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central venous
- Z-1000-2018 · Nov 27, 2017 · TerminatedARROWg+ard Blue MAC" Two-Lumen Central Venous Access Kit Product Usage: The Arrow CVC is indicated to provide short-term (< 30 days) central venous access for treatment of disease
- Z-2333-2017 · May 9, 2017 · Terminated1) ARROWg+ard Blue MAC Two-Lumen Central Venous Access Kit 2) ARROWg+ard Blue PSI Kit 3) ARROWg+ard Blue MAC Two-Lumen Central Venous Access Kit 4) ARROWg+ard Blue PSI Kit The MACT
- Z-2825-2015 · Aug 27, 2015 · TerminatedArrow Kits with Medtronic Covidien 0.9% Sodium Chloride Flush Syringes
- Z-0066-2015 · Aug 6, 2014 · TerminatedArrow Select Kits (ASK) and Maximal Barrier Precautions Kits (CDC) with BD Medical Posiflush 10mL Saline Flush Syringe.
- Z-0783-2010 · Nov 24, 2009 · TerminatedMAC (TM) Two Lumen Central Venous Access Kit with ARROWg+ard Blue (R) Access Device, Integral Hemostasis Valve, Sharps Safety Features and Maximal Barrier Precautions for use with
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page