ACUMED 80-4244Recalls & reported problems

Acumed LLC · T8 Stick Fit Hexalobe Driver · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10806378126598), received between Feb 16, 2026 and May 21, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 21, 2026Break

    IT WAS REPORTED: " A DRIVER TIP BROKE DURING A CASE. DOCTOR HAD EXPLAINED TO THE REP HE MAY HAVE OVER TORQUED THE SCREW DUE TO THE SCREW HEAD NOT SEATING IN PLATE."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25249876 ↗
  • MalfunctionApr 3, 2026Break

    IT WAS REPORTED: 1 X T8 DRIVER TIP BROKE DURING FINIAL TIGHTENING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24781957 ↗
  • MalfunctionMar 13, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED: BILATERAL DISTAL RADIUS FRACTURES THAT EXTEND INTO THE PROXIMAL RADIUS. PT. IS A RATHER LARGE MALE. WE USED A WIDE RIGHT PLATE WITH THE MEDIUM EXTENSION PLATE AND A STANDARD LONG LEFT PLATE WITH THE NEUTRAL EXTENSION. IN BOTH THE LEFT AND RIGHT, AS DR. (B)(6) WAS FINISHING IS PROXIMAL FIXATION, HE WAS FULLY SEATING HIS SCREWS AND THE SCREWS BROKE. THEY BROKE RIGHT AT THE NECK OF THE SCREW WHERE THE HEAD AND BODY MEET. HE DID NOT USE AN EXCESSIVE AMOUNT OF TORQUE AS HE WAS FULLY SEATING THESE SCREWS. I BELIEVE HE BROKE THE 2.7 X 16 IN THE RIGHT RADIUS AND 2.7 X 14 IN THE LEFT RADIUS BUT I'M NOT 100% ON THAT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24594485 ↗
  • MalfunctionFeb 16, 2026Break

    IT WAS REORTED THAT THE DRIVER BROKE DURING USE. THE PROCEDURE WAS COMPLETED USING ANOTHER DRIVER. THERE WAS NO REPORTED DELAY OR ADVERSE CONSEQUENCE TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24351742 ↗

Other Orthopedic manual surgical instrument devices

All Orthopedic manual surgical instrument devices →