Protocol Touch Administration Set with Small Catheter and Retention Cuff 390309Recalls & reported problems
Bracco Diagnostics Inc. · Protocol Touch Administration Set we/20fr. Tip · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10815112020153), received between Jun 28, 2019 and Jun 28, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Malposition of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Malposition of Device1
- Patient Device Interaction Problem1
Patient problems
- Bowel Perforation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 28, 2019Patient Device Interaction Problem; Malposition of Device; Patient Device Interaction Problem
THIS SPONTANEOUS INVALID DEVICE REPORT WAS RECEIVED BY BRACCO UK FROM A HEALTH PROFESSIONAL ON 12-JUN-2019 AND SENT TO BRACCO MILAN ON 21-JUN-2019. IT REFERS TO AN 82 YEAR-OLD FEMALE PATIENT WHO UNDERWENT AN UNSPECIFIED DIAGNOSTIC PROCEDURE USING PROTOCOL TOUCH ADMINISTRATION SET. HER MEDICAL HISTORY INCLUDED CHANGE IN BOWEL HABIT, FAECAL LEAKAGE, HEART ATTACK AND CARDIAC STENT INSERTION. IT WAS REPORTED THAT, DURING THE PROCEDURE, THE TIP OF THE CTC CATHETER PASSED THROUGH THE WALL OF THE RECTUM, NO APPARENT RESISTANCE WAS FELT BY THE EXPERIENCED RADIOGRAPHER. PATIENT HAD TO HAVE COLOSTOMY. MEDICAL DEVICE SERIAL NUMBER PROVIDED AS (B)(6). INVESTIGATION RESULTS HAVE BEEN PROVIDED BY BRACCO GROUP QUALITY: THE UNIT (S/N (B)(6) ) WAS REPAIRED BY (B)(6) ON 06 SEP 2019. IT WAS FOUND THAT THE REGULATOR WAS BROKEN. ADDITIONAL FOLLOW UP REVEALED THE FOLLOWING: THE REGULATOR WAS WORKING BUT WAS EXTREMELY NOISY. THE PRESSURE VALVE WAS ADDITIONALLY NOT FUNCTIONING. THE UNIT PASSED FINAL CALIBRATION. THE REGULATOR, PRESSURE VALVE (70 MMHG), AND ALSO THE CAP NUT WERE REPLACED. THE UNIT PASSED ALL FINAL QC TESTING AFTER REPAIRS WERE COMPLETED. A SUBSEQUENT INVESTIGATION WAS REQUESTED FROM THE MA
Patient problems: Bowel Perforation
MAUDE report 8744408 ↗
Other Insufflator, Automatic Carbon-Dioxide For Endoscope devices
- HIGH FLOW INSUFFLATION UNIT UHI-4Olympus Medical Systems Corp. · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE3 recalls6 deaths2,484 reports
- ENDOFLATOR UI500Karl Storz GmbH & Co. KG · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE193 reports
- HIGH FLOW INSUFFLATION UNIT UHI-4Olympus Medical Systems Corp. · Insufflator, Automatic Carbon-Dioxide For Endoscope1 recall9 reports
- ENDOSCOPIC CO2 REGULATION UNIT OLYMPUS UCROlympus Medical Systems Corp. · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE52 reports
- ENDOFLATOR UI400Karl Storz GmbH & Co. KG · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE40 reports
- ENDOSCOPIC CO2 REGULATION UNIT OLYMPUS UCROlympus Medical Systems Corp. · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE16 reports
- CO2MPACT 710300US Endoscopy · INSUFFLATOR, AUTOMATIC CARBON-DIOXIDE FOR ENDOSCOPE4 reports
- ENDOSCOPIC CO2 REGULATION UNIT OLYMPUS UCROlympus Medical Systems Corp. · Insufflator, Automatic Carbon-Dioxide For Endoscope2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page