SPECTRUM C6381Recalls & reported problems
Conmed Corporation · SPECTRUM II SUTURE HOOK, DISPOSABLE, 45° LEFT · Class 1
All models of SPECTRUM (12)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10845854019863), received between Feb 27, 2019 and Dec 14, 2023 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Fragmentation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Fragmentation2
- Break1
- Dull, Blunt1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 14, 2023Material Fragmentation; Material Fragmentation
THE CUSTOMER REPORTED THAT THE C6381, SPECTRUM II SUTURE HOOK, DISPOSABLE, 45 DEGREE LEFT, DEVICE WAS BEING USED DURING A SHOULDER ARTHROSCOPY PROCEDURE ON 23OCT23 WHEN IT WAS REPORTED ¿DURING SHOULDER ARTHROSCOPIC SURGERY, THE SPECTRUM HOOK BROKE INTO TWO PARTS AT THE TUBE/HOOK JUNCTION. IT FELL INTO THE PATIENT'S SHOULDER. THE SURGEON REMOVED THE PIECE WITH IMPORTANT DIFFICULTY GIVEN THE SMALL SIZE OF THE DEVICE.¿. THE PROCEDURE WAS COMPLETED AND THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION OR EXTENDED HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED ON THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18324213 ↗MalfunctionJan 29, 2020Material Fragmentation; Material Fragmentation
THIS DISTRIBUTOR REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE C6381 DEVICE WAS BEING USED DURING A BANKART PROCEDURE ON (B)(6) 2020 WHEN THE DEVICE TIP BROKE IN THE PATIENT. IT WAS REPORTED THAT ALL PIECES WERE REMOVED FROM THE PATIENT. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE AFTER A 2-MINUTE DELAY. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9642224 ↗MalfunctionFeb 27, 2019Break; Dull, Blunt; Break; Dull, Blunt
THE CUSTOMER REPORTED AN ISSUE WITH THE SPECTRUM II SUTURE HOOK, DISPOSABLE, 45 DEGREE LEFT, ITEM # C6381, LOT 966582, THAT OCCURRED ON (B)(6) 2019 DURING USE IN A SHOULDER STABILIZATION PROCEDURE. IT WAS REPORTED THAT THE C6381 SUTURE HOOK BROKE OFF IN A PATIENT'S SHOULDER. THE HOOK WAS RETRIEVED. IT IS INDICATED THAT THERE WAS NO IMPACT OR INJURY TO THE PATIENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A REPORTED 20-MINUTE DELAY. ADDITIONAL INFORMATION WAS RECEIVED FROM THE REPORTER AND THE HOSPITAL ON (B)(6) 2019. THE ARTHROSCOPIC BANKART PROCEDURE WAS APPROXIMATELY MIDWAY THROUGH, HAVING MOBILIZED THE TISSUE AND PREPARED THE BONE SURFACE. THE DOCTOR WAS HANDED THE LIMITED USE SUTURE HOOK FOR THE FIRST ATTEMPT AT PASSING THE SUTURE THROUGH TISSUE. THIS HOOK WAS BLUNT, THEREFORE SHE WAS OFFERED THE SINGLE USE SUTURE HOOK, WHICH SHE ACCEPTED AND ATTEMPTED TO USE TO PASS THROUGH THE SAME TISSUE AS THE FIRST ATTEMPT. THIS HOOK WAS REMOVED FROM THE PACKAGING JUST PRIOR TO THIS AND WAS PREVIOUSLY UNUSED. THE DOCTOR FOUND THAT THIS WAS ALSO BLUNT, AND THAT IS WHEN THE SUTURE HOOK BROKE OFF. IT TOOK APPROXIMATELY 20-MINS TO RETRIEVE THE BROKEN PART WHICH WAS RETRIEVED WHOLE. NO FRA
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8375605 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page