10K/24K 10K100Recalls & reported problems
Conmed Corporation · 10K/24K ARTHROSCOPY INFLOW TUBE SET · Class 2
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10845854041208), received between Feb 3, 2020 and Jun 20, 2022 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Particulates” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Particulates3
- Material Fragmentation2
Patient problems
- No Known Impact Or Consequence To Patient3
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 20, 2022Material Fragmentation; Material Fragmentation
THE DISTRIBUTOR REPORTED ON BEHALF OF THE CUSTOMER THAT THE DEVICE, 10K100, LINVATEC 10K100 ARTHR.TUBE SET WAS BEING USED ON (B)(6) 2022 AND " DURING A LAPAROSCOPIC SURGERY, WHILE A SURGEON WAS DOING IRRIGATION, A WHITE DEBRIS WAS FOUND. IT WAS REMOVED FROM A PATIENT'S BODY AND ALSO THERE WAS NO IMPACTS ON THE PATIENT. THIS 10K100 WAS DISPOSED OF AT THE HOSPITAL.¿ THERE WAS NO IMPACT OR INJURY TO THE PATIENT OR USER. THERE WAS NO REPORT OF MEDICAL INTERVENTION OR ANY PROLONGED HOSPITALIZATION FOR THE PATIENT. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE SAME DEVICE WITH A 2 MINUTE DELAY. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14747451 ↗MalfunctionJun 20, 2022Material Fragmentation; Material Fragmentation
THE DISTRIBUTOR REPORTED ON BEHALF OF THE CUSTOMER THAT THE DEVICE, 10K100, LINVATEC 10K100 ARTHR.TUBE SET WAS BEING USED ON 2022 AND " DURING A LAPAROSCOPIC SURGERY, WHILE A SURGEON WAS DOING IRRIGATION, A WHITE DEBRIS WAS FOUND. IT WAS REMOVED FROM A PATIENT'S BODY AND ALSO THERE WAS NO IMPACTS ON THE PATIENT. THIS 10K100 WAS DISPOSED OF AT THE HOSPITAL.¿ THERE WAS NO IMPACT OR INJURY TO THE PATIENT OR USER. THERE WAS NO REPORT OF MEDICAL INTERVENTION OR ANY PROLONGED HOSPITALIZATION FOR THE PATIENT. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE SAME DEVICE WITH A 2 MINUTE DELAY. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14747369 ↗MalfunctionFeb 11, 2020Particulates; Particulates
CONMED KOREA REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE 10K100, LINVATEC ARTHROSCOPY TUBING SET, WAS USED FOR AN ARTHROSCOPIC PROCEDURE ON (B)(6) 2020. A FOREIGN MATERIAL WAS FOUND IN THE TUBING POST OPERATIVELY. AT THIS TIME, NO DETERMINATION HAS BEEN MADE AS TO WHAT THE MATERIAL IS, BUT AN INVESTIGATION IS UNDERWAY. THERE IS NO REPORTED PATIENT INJURY OR IMPACT. THERE HAS BEEN NO REPORTED DELAY OF PROCEDURE. THE PROCEDURE WAS COMPLETED AS PLANNED. THIS REPORT IS BEING RAISED BASED ON DEVICE MALFUNCTION WITH POTENTIAL FOR INJURY DUE TO THE UNKNOWN DEBRIS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9693855 ↗MalfunctionFeb 11, 2020Particulates; Particulates
CONMED (B)(4) REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE 10K100, LINVATEC ARTHROSCOPY TUBING SET, WAS USED FOR AN ARTHROSCOPIC PROCEDURE ON (B)(6) 2020. A FOREIGN MATERIAL WAS FOUND IN THE TUBING POST OPERATIVELY. AT THIS TIME, NO DETERMINATION HAS BEEN MADE AS TO WHAT THE MATERIAL IS, BUT AN INVESTIGATION IS UNDERWAY. THERE IS NO REPORTED PATIENT INJURY OR IMPACT. THERE HAS BEEN NO REPORTED DELAY OF PROCEDURE. THE PROCEDURE WAS COMPLETED AS PLANNED. THIS REPORT IS BEING RAISED BASED ON DEVICE MALFUNCTION WITH POTENTIAL FOR INJURY DUE TO THE UNKNOWN DEBRIS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9693854 ↗MalfunctionFeb 3, 2020Particulates; Particulates
CONMED (B)(4) REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE 10K100, LINVATEC ARTHROSCOPY TUBING SET, WAS USED FOR AN ARTHROSCOPIC PROCEDURE ON (B)(6) 2020. A FOREIGN MATERIAL WAS FOUND INSIDE THE CASSETTE POST OP. IT COULD ALSO BE VISIBLE ON THE BACK TABLE IN THE SALINE SOLUTION. AT THIS TIME, NO DETERMINATION HAS BEEN MADE AS TO WHAT THE MATERIAL IS, BUT AN INVESTIGATION IS UNDERWAY. THERE IS NO REPORTED PATIENT INJURY OR IMPACT. THERE HAS BEEN NO REPORTED DELAY OF PROCEDURE. THE PROCEDURE WAS COMPLETED AS PLANNED, AS THIS WAS FOUND POST PROCEDURE. THIS REPORT IS BEING RAISED AS DEVICE MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9660324 ↗
Other ARTHROSCOPE devices
- FMS 283512Medos International Sàrl · ARTHROSCOPE1,800 reports
- Arthrex® AR-6480Arthrex, Inc. · ARTHROSCOPE949 reports
- FMS VUE 284002Depuy Mitek, LLC · ARTHROSCOPE829 reports
- MITEK 242018Medos International Sàrl · Arthroscope731 reports
- METRx® System 9560100Medtronic Sofamor Danek, Inc. · Arthroscope667 reports
- FMS VUE II 284004Medos International Sàrl · Arthroscope562 reports
- VAPR COOLPULSE 228146Depuy Mitek, LLC · ARTHROSCOPE474 reports
- FMS DUO 284580Depuy Mitek, LLC · ARTHROSCOPE458 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.