Monoject 1188827112Recalls & reported problems

Cardinal Health, Inc. · Standard Hypodermic Needle,Polypropylene Hub · Class 2

All models of Monoject (164)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10884521007444), received between Sep 9, 2019 and Sep 2, 2026 — classified as 2 injuries, 5 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak3
  • Incomplete or Inadequate Connection3
  • Detachment of Device or Device Component2
  • Break1
  • Fitting Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Foreign Body In Patient2
  • Needle Stick/Puncture1
  • No Consequences Or Impact To Patient1
  • No Patient Involvement1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjurySep 2, 2026Detachment of Device or Device Component

    It was reported that the physician inserted a 27G 1 1/2" Monoject standard hypodermic needle to provide local anesthetic and when the needle was removed, there was no needle on the hub. Additional information received on 05 AUG 2026 stated that that the needle was retained in the patient and based on follow up CT scan it was deemed unsafe to remove. On (b)(6) 2026 it was stated that the needle is in the patient's lung parenchyma. The patient has been discharged from the hospital.

    Patient problems: Foreign Body In Patient

    MAUDE report 50567869 ↗
  • MalfunctionApr 4, 2022Incomplete or Inadequate Connection; Incomplete or Inadequate Connection

    THE CUSTOMER REPORTED THAT THE 27-GAUGE NEEDLES ARE SUPPOSED TO LOCK ONTO THE SYRINGES AND THEY DON¿T LOCK. THEY KEEP SPINNING WHEN THEY PUT THEM ONTO THE SYRINGE. PER ADDITIONAL INFORMATION RECEIVED ON 18MAR2022, THERE WASN¿T ANY HARM DONE. THEY USED A DIFFERENT NEEDLE THEY HAD PURCHASED PREVIOUSLY AND THERE WERE NO PROBLEMS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13998842 ↗
  • MalfunctionApr 4, 2022Fluid/Blood Leak; Incomplete or Inadequate Connection; Fluid/Blood Leak; Incomplete or Inadequate Connection

    THE CUSTOMER REPORTED THAT THE 27-GAUGE NEEDLES ARE SUPPOSED TO LOCK ONTO THE SYRINGES AND THEY DON¿T LOCK. THEY KEEP SPINNING WHEN THEY PUT THEM ONTO THE SYRINGE. PER ADDITIONAL INFORMATION RECEIVED ON 18MAR2022, WHILE ADMINISTERING THE INJECTION, THE NEEDLE WAS IN THE PATIENT¿S FOOT AND BECAUSE THE NEEDLE COULDN¿T LOCK ON COMPLETELY, THE PRESSURE FROM THE LIQUID BEING PUSHED THROUGH THE NEEDLE FROM THE SYRINGE CAUSING THE NEEDLE TO BE PUSHED OFF OF THE SYRINGE. THIS RESULTED IN THE FLUID THAT WAS IN THE SYRINGE TO SPRAY OUT OF THE SYRINGE INSTEAD OF GOING INSIDE THE PATIENT¿S FOOT AS INTENDED. THERE WASN¿T ANY HARM DONE. THEY USED A DIFFERENT NEEDLE THEY HAD PURCHASED PREVIOUSLY AND THERE WERE NO PROBLEMS. THE SYRINGE USED WAS A 3RD PARTY SYRINGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13998812 ↗
  • MalfunctionApr 4, 2022Fluid/Blood Leak; Incomplete or Inadequate Connection; Fluid/Blood Leak; Incomplete or Inadequate Connection

    THE CUSTOMER REPORTED THAT THE 27-GAUGE NEEDLES ARE SUPPOSED TO LOCK ONTO THE SYRINGES AND THEY DON¿T LOCK. THEY KEEP SPINNING WHEN THEY PUT THEM ONTO THE SYRINGE. PER ADDITIONAL INFORMATION RECEIVED ON (B)(6) 2022, WHILE ADMINISTERING THE INJECTION, THE NEEDLE WAS IN THE PATIENT¿S FOOT AND BECAUSE THE NEEDLE COULDN¿T LOCK ON COMPLETELY, THE PRESSURE FROM THE LIQUID BEING PUSHED THROUGH THE NEEDLE FROM THE SYRINGE CAUSING THE NEEDLE TO BE PUSHED OFF OF THE SYRINGE. THIS RESULTED IN THE FLUID THAT WAS IN THE SYRINGE TO SPRAY OUT OF THE SYRINGE INSTEAD OF GOING INSIDE THE PATIENT¿S FOOT AS INTENDED. THERE WASN¿T ANY HARM DONE. THEY USED A DIFFERENT NEEDLE THEY HAD PURCHASED PREVIOUSLY AND THERE WERE NO PROBLEMS. THE SYRINGE USED WAS A 3RD PARTY SYRINGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13998810 ↗
  • InjuryAug 26, 2021Break; Break

    THE CUSTOMER REPORTED THAT THEY HAD A NEEDLE BREAK AND IT LODGED IN THE PATIENT¿S BACK.

    Patient problems: Foreign Body In Patient; Needle Stick/Puncture

    MAUDE report 12374525 ↗
  • MalfunctionNov 13, 2019Detachment of Device or Device Component; Detachment of Device or Device Component

    THE CUSTOMER REPORTED TO THE DISTRIBUTOR THAT THE DEVICE WILL NOT LOCK INTO THE SYRINGE; THE NEEDLE BLOWS OFF THE SYRINGE. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER STATED THAT THE ISSUE HAPPENED DURING CASE-SET UP. THE CUSTOMER FURTHER STATED THAT WHEN THEY ATTEMPT TO PUT THE NEEDLE ON THE SYRINGE IT DOES NOT LOCK. THEY TRIED SEVERAL NEEDLES AND SYRINGE COMBINATIONS AND IT WAS ALWAYS THE NEEDLE THAT HAD THE PROBLEM.

    Patient problems: No Patient Involvement

    MAUDE report 9318582 ↗
  • MalfunctionSep 9, 2019Fluid/Blood Leak; Fitting Problem; Fluid/Blood Leak; Fitting Problem

    THE CUSTOMER REPORTED THAT THE NEEDLES HAVE A LEAK. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER STATED THAT THE LOCKING PART OF THE NEEDLE DOES NOT LOCK ON TO THE SYRINGE AND CAUSES LEAKING. NO PATIENT HARM REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8976684 ↗

Other Needle, hypodermic, single lumen devices

All Needle, hypodermic, single lumen devices →