Puritan Bennett 4-840220AIQC-FRRecalls & reported problems
Covidien LP · 800 Series Ventilator System,Model 840 · Class 2
All models of Puritan Bennett (119)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 13
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 10884521076983), received between Apr 17, 2017 and Jul 15, 2024 — classified as 13 malfunctions.
The most frequently reported specific device problem is “No Flow” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- No Flow3
- Device Inoperable2
- Output Problem2
- Smoking2
- Communication or Transmission Problem1
- Device Displays Incorrect Message1
- Fire1
- Low Readings1
Patient problems
- No Patient Involvement6
- No Clinical Signs, Symptoms or Conditions5
- No Information4
- Insufficient Information1
Recent adverse event reports
The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 15, 2024Smoking; Smoking
IT WAS REPORTED THAT THE 840 VENTILATOR EMITTED SMOKE FROM THE POWER SUPPLY WHEN TURNED ON. THE VENTILATOR WAS NOT IN USE ON A PATIENT AT THE TIME OF THE REPORTED EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19746824 ↗MalfunctionJun 27, 2024Smoking; Output Problem; Smoking; Output Problem
ADDITONAL INFORMATION AS FOLLOWS: IT WAS REPORTED THAT DURING SERVICING, THE 840 VENTILATOR DID NOT PASS THE SHORT SELF TEST (SST). THE VENTILATOR WAS NOT IN USE ON A PATIENT AT THE TIME OF THE REPORTED EVENT.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 19627774 ↗MalfunctionJul 6, 2022No Flow; No Flow
IT WAS REPORTED THAT WHILE IN USE ON A PATIENT, THIS 840 VENTILATOR SHUT DOWN AND VENTILATION STOPPED. THE PATIENT WAS PLACED ON AN ALTERNATE VENTILATOR WITHOUT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14940432 ↗MalfunctionJan 12, 2022No Flow; Output Problem; No Flow; Output Problem
IT WAS REPORTED THAT DURING PREVENTATIVE MAINTENANCE, THIS 840 VENTILATOR GENERATED A VISUAL AND SOUND ALARM WITH A BACKGROUND CHECKS GUI (GRAPHICAL USER INTERFACE) DIAGNOSTIC CODE. IT WAS ADDITIONALLY REPORTED THAT CONTINUOUS AUDIBLE ALARM, ¿TECHNICAL ALARM¿, VISUAL MESSAGE ¿VENT INOP¿, AND POST BDU (POWER ON SELF TEST, BREATH DELIVERY UNIT) DIAGNOSTIC CODE WERE GENERATED. THE VENTILATOR WAS NOT IN USE ON A PATIENT AT THE TIME OF THE REPORTED EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13238889 ↗MalfunctionMar 4, 2021No Flow; No Flow
IT WAS REPORTED THAT WHILE IN USE ON A PATIENT, THIS 840 VENTILATOR SHUTDOWN AND HAD A LOSS OF VENTILATION. THE VENTILATOR STOPPED V ENTILATING THE PATIENT. THE PATIENT WAS PLACED ON AN ALTERNATE VENTILATOR WITHOUT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11418206 ↗MalfunctionApr 27, 2018Power Problem; Power Problem
IT WAS REPORTED THAT DURING SERVICING, THE 840 VENTILATOR HAD A POWER SUPPLY ISSUE. THE VENTILATOR WAS NOT IN USE ON A PATIENT AT THE TIME OF THE EVENT.
Patient problems: No Patient Involvement
MAUDE report 7470675 ↗MalfunctionOct 18, 2017Fire; Fire
IT WAS REPORTED THAT PRIOR TO USE, THE 840 VENTILATOR HAD A BURNING SMELL WHEN TURNED ON. THERE WAS A PENETRATION OF LIQUID ONTO THE SCREEN. THE VENTILATOR WAS NOT IN USE ON A PATIENT AT THE TIME OF THE REPORTED EVENT.
Patient problems: No Patient Involvement
MAUDE report 6959370 ↗MalfunctionAug 10, 2017No Display/Image; No Display/Image
IT WAS REPORTED THAT AN 840 VENTILATOR HAD A FROZEN DISPLAY. AT THIS TIME, IT IS UNKNOWN IF THERE WAS PATIENT INVOLVEMENT. A SERVICE ENGINEER INSPECTED THE DEVICE AND WAS NOT ABLE TO DUPLICATE THE ISSUE. THE UNIT PASSED ALL TESTING AND OPERATED WITHIN THE MANUFACTURING SPECIFICATIONS.
Patient problems: No Information; No Patient Involvement
MAUDE report 6787190 ↗MalfunctionAug 4, 2017Device Displays Incorrect Message; Device Displays Incorrect Message
IT WAS REPORTED THAT AN 840 VENTILATOR HAD A CONSTANT ALARM. NO PATIENT HARM OR INJURY REPORTED. ADDITIONAL DETAILS OF THE EVENT HAVE BEEN REQUESTED.
Patient problems: No Information
MAUDE report 6768061 ↗MalfunctionJun 8, 2017Low Readings; Low Readings
IT WAS REPORTED THAT, AN 840 VENTILATOR WAS GIVING LOW OXYGEN READINGS. ALTHOUGH REQUESTED, INFORMATION REGARDING THE INTERVENTION TAKEN ON THE BEHALF OF THE PATIENT WAS NOT BEEN PROVIDED.
Patient problems: No Information; No Patient Involvement
MAUDE report 6628905 ↗MalfunctionMay 30, 2017Device Inoperable; Device Inoperable
IT WAS REPORTED THAT AN 840 VENTILATOR HAD AN ERROR CODE DT0002 DURING POST (POWER ON SELF TEST). THE VENTILATOR WAS NOT ON A PATIENT AT THE TIME OF THE EVENT. THE COVIDIEN SERVICE ENGINEER (SE) INSPECTED THE DEVICE AND REPLACED THE BD PCBA (BREATH DELIVERY-PRINTED CIRCUIT BOARD) TO CORRECT THE ISSUE. THE UNIT PASSED ALL TESTING AND OPERATES WITHIN THE MANUFACTURING SPECIFICATIONS.
Patient problems: No Patient Involvement
MAUDE report 6598678 ↗MalfunctionApr 24, 2017Device Inoperable; Device Inoperable
IT WAS REPORTED THAT AN, 840 VENTILATOR GENERATED ERROR CODES WHICH RENDERED THE VENTILATOR INOPERABLE. ALTHOUGH REQUESTED, INFORMATION PERTAINING TO THE USE OF THE DEVICE AT THE TIME OF THE REPORTED EVENT AND PATIENT OUTCOME (IF APPLICABLE) HAS NOT BEEN PROVIDED. THE SERVICE ENGINEER (SE) INSPECTED THE DEVICE AND REPLACED THE BREATH DELIVERY UNIT (BDU) PRINTED CIRCUIT BOARD (PCB). THE UNIT PASSED ALL TESTING AND OPERATES WITHIN THE MANUFACTURING SPECIFICATIONS.
Patient problems: No Information
MAUDE report 6515320 ↗MalfunctionApr 17, 2017Communication or Transmission Problem; Communication or Transmission Problem
IT WAS REPORTED THAT THE VENTILATOR GENERATED LOSS OF COMMUNICATION CODES. THE VENTILATOR WAS NOT ON A PATIENT AT THE TIME OF THE EVENT. THE SERVICE ENGINEER EVALUATED THE VENTILATOR AND REPLACED THE GRAPHIC USER INTERFACE (GUI) PRINTED CIRCUIT BOARD (PCB). THE VENTILATOR PASSED SELF-TESTING.
Patient problems: No Patient Involvement
MAUDE report 6497023 ↗
Other VENTILATOR, CONTINUOUS, FACILITY USE devices
- Trilogy Trilogy100 Ventilator, United StatesRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE92 deaths8,161 reports
- Trilogy Evo Trilogy Evo, USARespironics, Inc. · Ventilator, continuous, facility use6 recalls50 deaths4,393 reports
- Trilogy 100 Trilogy 100 W/ Bluetooth, USARespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE65 deaths4,569 reports
- CARESCAPE R860Datex-Ohmeda Inc · VENTILATOR, CONTINUOUS, FACILITY USE1 recall1 death4,346 reports
- HAMILTON-C1 161001Hamilton Medical AG · Ventilator, Continuous, Facility Use2 recalls12 deaths1,849 reports
- Trilogy Trilogy O2 Ventilator JapanRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE7 deaths1,900 reports
- Trilogy Trilogy 202 Ventilator InternationalRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE11 deaths1,564 reports
- HAMILTON-C6 160021Hamilton Medical AG · Ventilator, Continuous, Facility Use5 recalls10 deaths1,175 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page