INVOS 5100C-PBRecalls & reported problems
Covidien LP · Preamplifier B, Channel 3 and 4 · Class 2
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10884521145580), received between Dec 28, 2018 and Jan 31, 2024 — classified as 8 malfunctions.
The most frequently reported specific device problem is “Device Alarm System” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Device Alarm System3
- Failure to Analyze Signal3
- Low Readings2
- Communication or Transmission Problem1
- Image Display Error/Artifact1
- Incorrect Measurement1
- Patient Device Interaction Problem1
- Temperature Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Insufficient Information2
- Burn(s)1
- No Patient Involvement1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 31, 2024Low Readings; Low Readings
ACCORDING TO THE REPORTER, THE DEVICE GAVE LOW VALUES. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18618925 ↗MalfunctionJan 5, 2024Incorrect Measurement; Incorrect Measurement
ACCORDING TO THE REPORTER, THE DEVICE HAD NO RELIABLE READINGS. THERE WAS NO REPORTED PATIENT INVOLVEMENT OR OUTCOME.
Patient problems: Insufficient Information
MAUDE report 18455045 ↗MalfunctionNov 17, 2023Device Alarm System; Image Display Error/Artifact; Failure to Analyze Signal; Device Alarm System; Image Display Error/Artifact; Failure to Analyze Signal
ACCORDING TO THE REPORTER, PRIOR TO USE, THE UNIT WAS NOT READING. THERE WERE NO ALARMS OR ERROR CODES. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18166252 ↗MalfunctionNov 17, 2023Device Alarm System; Failure to Analyze Signal; Communication or Transmission Problem; Device Alarm System; Failure to Analyze Signal; Communication or Transmission Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE UNIT WAS NOT READING. THERE WERE NO ALARMS OR ERROR CODES. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18161558 ↗MalfunctionNov 15, 2023Device Alarm System; Failure to Analyze Signal; Device Alarm System; Failure to Analyze Signal
ACCORDING TO THE REPORTER, PRIOR TO USE, THE UNIT WAS NOT READING. THERE WERE NO ALARMS OR ERROR CODES. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18144678 ↗MalfunctionAug 15, 2023Temperature Problem; Temperature Problem
ACCORDING TO THE REPORTER, OCCURRED PRE-OPERATIVELY, THE MAIN CABLE OF THE UNIT WAS DAMAGED AND BURNED. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17553235 ↗MalfunctionJan 28, 2022Use of Device Problem; Patient Device Interaction Problem; Use of Device Problem; Patient Device Interaction Problem
ACCORDING TO THE REPORTER, THE CHILD'S BACK BURNED BY THE SENSOR AFTER LONG SURGERY (LIVER TRANSPLANT, 12 HOURS). EITHER A PRESSURE ULCER OR A SENSOR BURN BECAUSE UNFORTUNATELY THE LESION WAS DISCOVERED A FEW DAYS AGO. THE PATIENT HAD BURNED.
Patient problems: Burn(s); Insufficient Information
MAUDE report 13386441 ↗MalfunctionDec 28, 2018Low Readings; Low Readings
ACCORDING TO THE REPORTER, DURING SETUP, THE UNIT HAD LOW READINGS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 8204653 ↗
Other Oximeter, tissue saturation devices
- INVOS PMAC71RSCCovidien LP · Oximeter, tissue saturation1 recall67 reports
- HEMOSPHERE FORESIGHT MODULE HEMFSM10Edwards Lifesciences LLC · Oximeter, Tissue Saturation1 recall12 reports
- INVOS PMAC71RICCovidien LP · Oximeter, tissue saturation1 recall4 reports
- FORE-SIGHT ELITE® 01-06-3000Cas Medical Systems, Inc. · Oximeter, Tissue Saturation1 recall1 death2 reports
- Invos 5100C-EUCovidien LP · Oximeter, tissue saturation22 reports
- INVOS PM7100Covidien LP · Oximeter, tissue saturation21 reports
- INVOS PM7100Covidien LP · Oximeter, tissue saturation18 reports
- INVOS 5100C-PACovidien LP · Oximeter, tissue saturation15 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.