VersaOne B5STSRecalls & reported problems
Covidien LP · Bladed Trocar with Smooth Cannula · Class 2
All models of VersaOne (47)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10884521539846), received between Aug 30, 2017 and Jul 17, 2025 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component2
- Break1
- Device Packaging Compromised1
- Difficult to Insert1
- Difficult to Remove1
Patient problems
- Foreign Body In Patient2
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryJul 17, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC APPENDECTOMY PROCEDURE, DURING INSERTION OF THE TROCAR, THE TIP CRUMBLED, AND BLUE PIECES REMAINED ON THE WALLS OF THE PATIENT'S BELLY. BECAUSE PLASTIC DEBRIS WAS EXTRAPERITONEAL AND SCATTERED, IT CANNOT BE REMOVED.
Patient problems: Foreign Body In Patient
MAUDE report 22536129 ↗MalfunctionMar 13, 2024Difficult to Insert; Difficult to Insert
ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC CHOLECYSTECTOMY, IT WAS IMPOSSIBLE TO INSERT THE TROCAR IN TO THE PATIENT. ANOTHER DEVICE WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY,
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18899248 ↗InjuryJul 10, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, DURING A PROCEDURE, DEVICE COMPONENTS FELL INTO THE CAVITY OF THE PATIENT. INTRA-ABDOMINAL VISUALIZATION SHOWED SMALL BLUE FRAGMENTS AND PRESENCE OF SCRATCHES ON THE PLASTIC AT THE TROCAR ORIFICE. ABUNDANT WASHING WAS PERFORMED TO RESOLVE THE ISSUE. THE EVENT LED TO EXTENDED OPERATING TIME.
Patient problems: Foreign Body In Patient; No Code Available
MAUDE report 10260414 ↗MalfunctionAug 30, 2017Difficult to Remove; Device Packaging Compromised; Difficult to Remove; Device Packaging Compromised
ACCORDING TO THE REPORTER: OCCURRED DURING A LAPAROSCOPIC HYSTERECTOMY. THE VESSEL SEALING DEVICE CAUSED THE INSUFFLATION MACHINE TO ALARM DUE TO LACK OF FLOW THROUGH THE TROCAR. THE SEAL OF THE PORT WAS DAMAGED. THE TROCAR BECAME STUCK ON THE SUCTION IRRIGATOR AND WHEN THEY WERE PULLED APART, THE INTERNAL SEAL OF THE TROCAR BROKE. TO CORRECT THE ISSUE, THE SURGICAL TEAM HAD TO SWITCH THE GAS TUBE FROM ONE TROCAR TO ANOTHER EACH TIME THE VESSEL SEALING DEVICE WAS PASSED BETWEEN THEM. A SECOND TROCAR WAS USED WHEN THE SUCTION IRRIGATOR WAS STUCK INSIDE THE TROCAR. NO PATIENT INJURY OR EXTENSION IN SURGICAL TIME. PATIENT STATUS IS ALIVE, NO INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6831881 ↗
Other Laparoscope, general & plastic surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.