VersaOne UNVCA5STBRecalls & reported problems
Covidien LP · Universal Fixation Balloon Cannula;Standard · Class 2
All models of VersaOne (47)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10884521809031), received between Aug 22, 2024 and Feb 4, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Material Split, Cut or Torn” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Split, Cut or Torn3
- Break2
- Gas/Air Leak2
- Inflation Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 4, 2026Break
ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC HYSTERECTOMY THE 5 MM BALLOON PORT BALLOON POPPED DURING SURGERY. A NEW DEVICE WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24256801 ↗MalfunctionNov 27, 2025Break; Break
ACCORDING TO THE REPORTER, IN A LAPAROSCOPIC JEJUNOSTOMY TUBE INSERTION, AT THE END OF THE CASE, THE BALLOON POPPED. AS THE SURGEON REALIZED THE ISSUE AT THE END OF THE PROCEDURE, NO FURTHER ACTION WAS DONE TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23667622 ↗MalfunctionSep 16, 2025Material Split, Cut or Torn; Material Split, Cut or Torn
ACCORDING TO THE REPORTER, DURING A TOTAL LAPAROSCOPIC HYSTERECTOMY, THE BALLOON ON THE TROCAR DEFLATED AND THE SEAL WAS DAMAGED. A NEW DEVICE WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23066160 ↗MalfunctionJan 29, 2025Gas/Air Leak; Material Split, Cut or Torn; Gas/Air Leak; Material Split, Cut or Torn
ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC NON-CANCER GYNECOLOGY (GYN) PROCEDURE, THE DEVICE HAS A SEAL DAMAGE. IT WAS ALSO NOTED THAT THE BALLOON TROCAR LOST INFLATION. ANOTHER TROCAR WAS REPLACED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21269705 ↗MalfunctionJan 28, 2025Inflation Problem; Inflation Problem
IT WAS REPORTED THAT DURING A LAPAROSCOPIC NON-CANCER GYNECOLOGICAL PROCEDURE, THE BALLOON ON THE TROCAR WOULD NOT INFLATE OR HOLD AIR. ADDITIONALLY, A DAMAGED SEAL WAS NOTED ON THE DEVICE. THE ISSUE WAS RESOLVED BY REPLACING THE TROCAR WITH ANOTHER 5 MILLIMETER TROCAR. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21252512 ↗MalfunctionAug 22, 2024Gas/Air Leak; Material Split, Cut or Torn; Gas/Air Leak; Material Split, Cut or Torn
ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC SUPRACERVICAL HYSTERECTOMY, AT THE BEGINNING OF THE CASE, THERE WAS A DAMAGED SEAL AND WAS NOT COMPLETE. IT WAS NOTED THAT THE BALLOON INFLATED AND LEAKED AIR AND WENT LIMP SO IT WAS NOT HOLDING THE TROCAR IN PLACE ANYMORE. THE USER CARRIED ON WITH THE PROCEDURE TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20025358 ↗
Other Laparoscope, general & plastic surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page