- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886705007714), received between Nov 23, 2022 and Mar 17, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Material Deformation1
Patient problems
- Joint Laxity1
- Nerve Damage1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMar 17, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS FILE IS A REVIEW OF THE FOLLOWING JOURNAL ARTICLE: ORLETSKII, A., ET AL (2022) SURGICAL TREATMENT OF POST-TRAUMATIC INSTABILITY OF THE SHOULDER JOINT IN ATHLETES. N. N. PRIOROV HERALD OF TRAUMATIC SURGERY AND ORTHOPEDICS, VOL. 29, NO. 1, PAGES 5-18 (RUSSIA). THE STUDY EMPHASIZES ON THE ASSESSMENT OF RESULTS AND COMPLICATIONS DURING THE POSTOPERATIVE PERIOD, SURGICAL INTERVENTION TIME, AND TECHNICAL DIFFICULTIES AND NUANCES DURING THE PERFORMANCE OF THE ARTHROSCOPIC LATARJET PROCEDURE AMONG PROFESSIONAL ATHLETES AND AMATEUR ATHLETES WITH POST-TRAUMATIC SHOULDER JOINT DEFECTS. THE PATIENTS EVALUATED ON COURSE OF THIS STUDY: 50 PATIENTS . THE ARTICLE DESCRIBES THE FOLLOWING PROCEDURE: ARTHROSCOPIC LATARJET PROCEDURE. THE DEVICES INVOLVED WERE: HEALIX 5.5 AWL/TAP. COMPLICATIONS DESCRIBED: 1 UNKNOWN PATIENT EXPERIENCED AXILLARY NERVE INJURY, WHICH RESOLVED AFTER 3 WEEKS OF ADDITIONAL TREATMENT. 1 PATIENT EXPERIENCED RECURRENT DISLOCATION. A COPY OF THIS LITERATURE ARTICLE IS ATTACHED TO THIS MEDWATCH REPORT.
Patient problems: Joint Laxity; Nerve Damage
MAUDE report 16565217 ↗MalfunctionNov 23, 2022Material Deformation; Material Deformation
THIS IS REPORT 2 OF 2 FOR (B)(4). IT WAS REPORTED BY THE SALES REP THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE HEALIX 5.5 AWL/TAP WAS BENT. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO PATIENT CONSEQUENCES OR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15857037 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page