MILAGRO 231807Recalls & reported problems
Medos International Sàrl · MILAGRO INTERFERENCE SCREW Absorbable - TCP/PLGA 6 X 23mm · Class 2 · Implant
All models of MILAGRO (26)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Milagro absorbable interference screw is a fixation device. Reports mostly describe the screw breaking during knee surgery, sometimes with fragments removed, along with difficult insertion and rare unsterile packaging. The 98 reports mention no deaths and 2 injuries. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 97
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 97 adverse event reports that list this exact device (DI 10886705010752), received between Dec 14, 2017 and Sep 29, 2026 — classified as 2 injuries, 95 malfunctions.
The most frequently reported specific device problem is “Break” (83 reports).
5 other recalls cover devices cleared under the same FDA submission (K103831, K150209); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break83
- Difficult to Advance6
- Crack2
- Delivered as Unsterile Product2
- Entrapment of Device2
- Migration2
- Adverse Event Without Identified Device or Use Problem1
- Device Handling Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions59
- No Consequences Or Impact To Patient24
- Not Applicable13
- No Known Impact Or Consequence To Patient3
- Failure of Implant1
- Fluid Discharge1
- Pain1
- Swelling/ Edema1
Recent adverse event reports
The 25 most recent of 97 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2026Difficult to Advance
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50938195 ↗MalfunctionJun 24, 2026Break
IT WAS REPORTED THAT DURING AN ARTHROSCOPY SURGERY, WHEN THE MILAGRO SCREW WAS INSERTED, THE SCREW WAS BROKEN. ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25605589 ↗MalfunctionJun 18, 2026Delivered as Unsterile Product
IT WAS REPORTED THAT THE MILAGRO INSCR SMALL-SIZE 6X23 DEVICE WAS FOUND TO BE UNSTERILIZED. IT WAS NOT REPORTED IF THE DEVICE WAS USED IN SURGERY. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS IN A SURGICAL PROCEDURE OR IF A SPARE DEVICE WAS AVAILABLE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25547299 ↗MalfunctionApr 28, 2026Break
IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION SURGERY, THE MILAGRO SCREW WAS BROKEN. ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25014257 ↗MalfunctionApr 23, 2026Break
IT WAS REPORTED THAT DURING KNEE ARTHROSCOPY MEDIAL COLLATERAL LIGAMENT REPAIR SURGERY, WHEN INSERTING THE MILAGRO SCREW DEVICE, THE SCREW WAS BROKEN, ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24971103 ↗MalfunctionApr 8, 2026Difficult to Advance
IT WAS REPORTED THAT DURING INSERTION OF THE 6X23MM MILAGRO SCREW FOR MEDIAL PATELLA FEMORAL LIGAMENT RECONSTRUCTION SURGICAL PROCEDURE, THE SCREW WOULD NOT ENGAGE DURING THE PROCESS. EFFORTS WERE MADE TO INSERT THE SCREW THREE SEPARATE TIMES, EACH TIME WITHOUT SUCCESS. FOLLOWING THESE UNSUCCESSFUL ATTEMPTS, AN ALTERNATIVE SCREW WAS OPENED FOR USE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED, AND NO FRAGMENTS WERE GENERATED. A 4-MINUTE SURGICAL DELAY WAS NOTED AND THERE WAS NO HARM TO THE PATIENT. THE DEVICE IS NOT AVAILABLE FOR ANALYSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24821067 ↗MalfunctionMar 26, 2026Break
IT WAS REPORTED THAT DURING ARTHROSCOPIC LIGAMENT REPAIR SURGERY SURGERY, WHEN INSERTING THE MILAGRO SCREW DEVICE, THE SCREW WAS BROKEN, ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24700106 ↗MalfunctionMar 24, 2026Break
IT WAS REPORTED THAT DURING AN UNSPECIFIED ARTHROSCOPIC PROCEDURE THAT THE MILAGRO INSCR SMALL SIZE 6X23 SCREW ANCHOR DEVICE BROKE DURING INSERTION. ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24682748 ↗MalfunctionMar 20, 2026Break
IT WAS REPORTED THAT DURING AN ARTHROSCOPIC LIGAMENT REPAIR PROCEDURE; IT WAS DISCOVERED THAT THE SCREW ON THE MILAGRO INSCR SMALL SIZE 6X23 DEVICE BROKE. ALL THE BROKEN PARTS WERE REMOVED FROM THE PATIENT. THERE WERE NO DELAYS IN THE SURGICAL PROCEDURE. IT WAS REPORTED THAT A SPARE DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24652238 ↗MalfunctionMar 19, 2026Break
IT WAS REPORTED THAT DURING AN ARTHROPLASTY SURGERY THE SCREW ON THE MILAGRO INSCR SMALL SIZE 6 X 23 DEVICE BROKE DURING INSERTION. ALL BROKEN PIECES WERE REMOVED FROM THE PATIENT. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS TO THE SURGICAL PROCEDURE. IT WAS REPORTED THAT A SPARE DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24637583 ↗MalfunctionMar 17, 2026Break
IT WAS REPORTED THAT DURING A SPORTS MEDICINE ARTHROSCOPY SURGICAL PROCEDURE IT WAS OBSERVED THAT THE MILAGRO INSCR SMALL DEVICE SCREW BROKE OFF. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24618762 ↗MalfunctionFeb 4, 2026Break
THIS IS EVENT 2 OF 4 OF (B)(4). IT WAS REPORTED THAT DURING A JOINT SURGICAL PROCEDURE IT WAS OBSERVED THAT 2X MILAGRO ADVANCE SCREW DEVICES AND 2X RIGIDFIX FEM 3.3MM S/T XPIN DEVICES BROKE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE SUCCESSFULLY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24261077 ↗MalfunctionDec 17, 2025Break; Break
IT WAS REPORTED THAT DURING A LATERAL COLLATERAL LIGAMENT (LCL) SURGICAL PROCEDURE, WHILE ATTEMPTING TO INSERT A MILAGRO INSCR SMALL SIZE 6X23 SCREW DEVICE AND A MILAGRO INSCR SMALL SIZE 5X23 SCREW DEVICE, IT WAS OBSERVED THAT BOTH SCREWS SNAPPED AT THE PROXIMAL ENDS. IT WAS REPORTED THAT THE EVENT COULD HAVE BEEN AVOIDED IF THE CORRECT INSERTION DEVICE WAS PROVIDED. IT WAS REPORTED THAT NO DEBRIS WAS LEFT IN THE PATIENT AND THE SMALL FRAGMENTS WERE RETRIEVED. IT WAS REPORTED THAT ANOTHER DEVICE WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. IT WAS REPORTED THAT THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT, OR SURGICAL DELAY. NO ADDITIONAL INFORMATION COULD BE PROVIDED. THIS IS REPORT 1 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23832111 ↗MalfunctionDec 16, 2025Break; Break
IT WAS REPORTED THAT DURING AN ANTERIOR BONE GRAFT RECONSTRUCTION SURGICAL PROCEDURE, WHEN INSERTING THE MILAGRO INSCR SMALL SIZE 6X23 SCREW DEVICE, IT WAS OBSERVED THAT THE SCREW WAS BROKEN. IT WAS REPORTED THAT ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23822434 ↗MalfunctionDec 16, 2025Break; Break
IT WAS REPORTED THAT DURING A KNEE ARTHROSCOPY SURGERY, WHEN INSERTING THE MILAGRO INSCR SMALL SIZE 6X23 SCREW, IT WAS OBSERVED THAT THE SCREW WAS BROKEN. IT WAS REPORTED THAT ALL THE PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23819115 ↗MalfunctionDec 4, 2025Break; Break
THIS IS REPORT 2 OF 2 FOR (B)(4). IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT REPAIR PROCEDURE, IT WAS DISCOVERED THAT AFTER FIRST FIRING, TWO PLATES FROM THE TRUESPAN 24 DEGREE PEEK DEVICE WERE DEPLOYED SIMULTANEOUSLY. IT WAS FURTHER REPORTED THAT WHEN THE SCREW FROM THE MILAGRO INSCR SMALL SIZE 6X23 DEVICE WAS INSERTED, IT BROKE OFF. ALL THE PIECES WERE REMOVED FROM THE PATIENT. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS TO THE SURGICAL PROCEDURE. IT WAS REPORTED THAT SPARE DEVICES WERE USED TO COMPLETE THE SURGERY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23720888 ↗MalfunctionDec 4, 2025Break; Break
IT WAS REPORTED THAT DURING A KNEE ARTHROSCOPY PROCEDURE, IT WAS DISCOVERED THAT THE SCREW ON THE MILAGRO INSCR SMALL SIZE 6X23 DEVICE BROKE OFF. ALL THE BROKEN PARTS WERE REMOVED FROM THE PATIENT. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS TO THE SURGICAL PROCEDURE. IT WAS REPORTED THAT A SPARE DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23720559 ↗MalfunctionNov 4, 2025Break; Break
THIS IS REPORT 2 OF 3 OF THE SAME EVENT IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT (ACL) SURGICAL PROCEDURE IT WAS OBSERVED THAT THE RGDLOOP ADJUSTABLE STND DEVICE SUTURE WAS BROKEN OFF WHEN TIGHTENED. THE USER CHANGED TO ANOTHER ONE TO CONTINUE THE SURGERY, THE SAME PROBLEM HAPPENED AGAIN. THE USER THEN CHANGED THE ANCHOR TO CONTINUE THE SURGERY, THE ANCHOR WAS BROKEN OFF. REMOVED ALL THE BROKEN PARTS. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23468274 ↗MalfunctionOct 21, 2025Break; Break
IT WAS REPORTED THAT DURING A KNEE ARTHROSCOPY SURGICAL PROCEDURE IT WAS OBSERVED THAT THE MILAGRO INSCR SMALL SIZE 6X23 DEVICE ANCHOR WAS BROKEN OFF. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23346775 ↗MalfunctionSep 19, 2025Break; Break
IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT (ACL) REPAIR SURGICAL PROCEDURE IT WAS OBSERVED THAT THE MILAGRO INSCR SMALL DEVICE ANCHOR WAS BROKEN OFF. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23100675 ↗MalfunctionSep 19, 2025Break; Break
IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT (ACL) REPAIR SURGICAL PROCEDURE IT WAS OBSERVED THAT THE MILAGRO INSCR SMALL DEVICE ANCHOR WAS BROKEN OFF. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23095510 ↗MalfunctionSep 15, 2025Break; Break
REPORT 2 OF 2 FOR (B)(4). IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT REPAIR SURGERY, IT WAS OBSERVED THAT THE RGDLOOP ADJUSTABLE STND DEVICE SUTURE WAS BROKEN OFF WHEN THE SUTURE WAS TIGHTENED AND THE MILAGRO INSCR SMALL SIZE 6X23 DEVICE WAS BROKEN WHEN IT WAS INSERTED. IT WAS REPORTED THAT ALL PIECES WERE REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23050096 ↗MalfunctionSep 9, 2025Product Quality Problem; Difficult to Advance; Product Quality Problem; Difficult to Advance
IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT (ACL) RECONSTRUCTION SURGICAL PROCEDURE, IT WAS OBSERVED THAT WHEN THE SURGEON ATTEMPTED TO INSERT A MILAGRO INSCR SMALL SIZE 6X23 SCREW FOR LATERAL TENODESIS, HE REALIZED THAT THE SCREW WAS NOT CANNULATED, MAKING INSERTION IMPOSSIBLE. IT WAS REPORTED THAT ANOTHER DEVICE WAS USED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. IT WAS REPORTED THAT THERE WAS A 5-MINUTE DELAY IN THE PROCEDURE DUE TO THE EVENT. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT REPORTED. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23006116 ↗MalfunctionAug 5, 2025Break; Break
IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE FOR RECONSTRUCTION OF PATELLAR THE LIGAMENT IN THE KNEE, IT WAS OBSERVED THAT THE MILAGRO INSCR DEVICE ANCHOR BROKE OFF. THE USER CHANGED TO ANOTHER ONE TO CONTINUE THE SURGERY, HOWEVER THE SAME PROBLEM HAPPENED AGAIN. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED. THIS IS REPORT 2 OF 2 OF (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22719693 ↗MalfunctionAug 5, 2025Break; Break
IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE FOR RECONSTRUCTION OF PATELLAR THE LIGAMENT IN THE KNEE, IT WAS OBSERVED THAT THE MILAGRO INSCR DEVICE ANCHOR BROKE OFF. THE USER CHANGED TO ANOTHER ONE TO CONTINUE THE SURGERY, HOWEVER THE SAME PROBLEM HAPPENED AGAIN. ALL BROKEN PARTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED. THIS IS REPORT 1 OF 2 OF (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22719675 ↗
FDA clearance and classification
Cleared through 510(k) K150209 on Oct 6, 2015 (decision: Substantially Equivalent). Submitted by Depuy Mitek, A Johnson and Johnson Company as “Healix BR Anchor, Healix PEEK Anchor, Healix Transtend, Gryphon T and P BR Anchor, Gryphon PEEK Anchor, VersaLok Anchor, Bioknotless BR Anchor, Lupine BR Anchor, PanaLok Anchor,PanaLok Anchor with Orthocord, PanaLok RC QuickAnchor Plus; PanaLok RC QuickAnchor Plus Dual Suture, PanaLok RC QuickAnchor Plus w/Orthocord; PanaLok RC QuickAnchor Plus Dual Suture w/Orthocord, PanaLok Loop Anchor, Lupine Loop Anchor, PanaLok RC Lop Anchor, BioKnotless Anchor, BioKnotless RC Anchor, RC Loop Anc”. The FDA review took 249 days. FDA record ↗
Cleared through 510(k) K103831 on Jul 21, 2011 (decision: Substantially Equivalent). Submitted by Depuy Mitek, A Johnson & Johnson Company as “Depuy Mitek Milagro Interference Screw Model 231803, 231804, 231807, 231809”. The FDA review took 203 days. FDA record ↗
The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K103831, K150209. One submission often covers many models, so check the product and lot details in each record.
- Z-1680-2023 · Apr 13, 2023 · Open, ClassifiedDePuy Mitek BIOKNOTLESS Rapid W/ OC-Indicated for use in soft tissue to bone fixation in association with adequate postoperative immobilization Model Number: 212722
- Z-1677-2023 · Apr 13, 2023 · Open, ClassifiedDePuy Mitek BIOKNOTLESS Plus w/ Ethibond-Iindicated for use in soft tissue to bone fixation in association with adequate postoperative immobilization Model Number: 212724
- Z-1679-2023 · Apr 13, 2023 · Open, ClassifiedDePuy Mitek BIOKNOTLESS Plus w/ OC-Indicated for use in soft tissue to bone fixation in association with adequate postoperative immobilization Model Number: 212726
- Z-1678-2023 · Apr 13, 2023 · Open, ClassifiedDePuy Mitek BIOKNOTLESS Plus w/ Panacryl-Indicated for use in soft tissue to bone fixation in association with adequate postoperative immobilization Model Number: 212725
- Z-1681-2023 · Apr 13, 2023 · Open, ClassifiedDePuy Mitek BIOKNOTLESS Rapid w/ Pan-Indicated for use in soft tissue to bone fixation in association with adequate postoperative immobilization Model Number: 212723
Common questions about the MILAGRO 231807
Has the MILAGRO 231807 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10886705010752), based on the FDA recall file dated Nov 27, 2026. However, 5 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the MILAGRO 231807?
The FDA's MAUDE database lists 97 adverse event reports for this device, received between Dec 14, 2017 and Sep 29, 2026. In those reports, the most common specific device problems are “Break” (83), “Difficult to Advance” (6) and “Crack” (2); the most common patient problems are “Not Applicable” (13), “Failure of Implant” (1) and “Fluid Discharge” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MILAGRO 231807?
None of the reports are classified as deaths, 2 as injuries and 95 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MILAGRO 231807 FDA approved?
It was cleared through 510(k) K103831 on Jul 21, 2011; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the MILAGRO 231807 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the MILAGRO 231807, and is it still sold?
The FDA's device database lists Medos International Sàrl as the company responsible for it (brand MILAGRO, model 231807). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone498 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone248 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-325Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-550Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-425Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page