Medos International Sàrl · Anteromedial Femoral Aimer 5.5mm · Class 1

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10886705013548), received between Jun 6, 2018 and Sep 15, 2024 — classified as 3 injuries, 5 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Material Twisted/Bent2
  • Peeled/Delaminated2
  • Corroded1
  • Degraded1
  • Inaccurate Information1
  • Loose or Intermittent Connection1

Patient problems

  • No Consequences Or Impact To Patient4
  • No Code Available2
  • Not Applicable2
  • Foreign Body In Patient1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 15, 2024Inaccurate Information; Inaccurate Information

    THIS IS REPORT 1 OF 5 FOR (B)(4). IT WAS REPORTED FROM CHINA THAT THE LOT NUMBER ON THE LABEL ON THE ANTEROMEDIAL FEMORAL AIMER, 5.5MM DEVICE WAS NOT CONSISTENT WITH THE LOT NUMBER THAT WAS ETCHED ON IT. THIS EVENT DID NOT OCCUR DURING SURGERY. THERE WAS NO PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20220928 ↗
  • MalfunctionSep 23, 2020Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED BY SALES REP VIA PHONE THAT DURING AN ACL RECONSTRUCTION, TWO ANTEROMEDIAL FEMORAL AIMER 5.5 MM WERE SLIGHTLY BENT WHICH AFFECTED VISUALIZATION OF CALIBRATORS. SURGEON WAS ABLE TO ESTIMATE DEPTH OF TUNNEL WITHOUT THE CALIBRATIONS (AFTER THEY WERE WORN OFF DURING DRILLING) NO SURGICAL DELAY OR PATIENT CONSEQUENCES REPORTED. DEVICES ARE AVAILABLE TO BE RETURNED FOR EVALUATION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10576936 ↗
  • MalfunctionSep 23, 2020Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED BY SALES REP VIA PHONE THAT DURING AN ACL RECONSTRUCTION, TWO ANTEROMEDIAL FEMORAL AIMER 5.5 MM WERE SLIGHTLY BENT WHICH AFFECTED VISUALIZATION OF CALIBRATORS. SURGEON WAS ABLE TO ESTIMATE DEPTH OF TUNNEL WITHOUT THE CALIBRATIONS (AFTER THEY WERE WORN OFF DURING DRILLING) NO SURGICAL DELAY OR PATIENT CONSEQUENCES REPORTED. DEVICES ARE AVAILABLE TO BE RETURNED FOR EVALUATION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10576887 ↗
  • MalfunctionJul 24, 2020Corroded; Degraded; Corroded; Degraded

    THIS IS REPORT 4 OF 5 FOR THE SAME EVENT. IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING STERILIZATION PRIOR TO AN UNKNOWN SURGERY ON AN UNKNOWN DATE, IT WAS OBSERVED THAT THE GRAFT PREP SYS SLIDERUNIT (2 REQ) EA DEVICE HAD SOME RUST SPOTS PARTICULARLY ON THE WRITINGS (LETTERS). IT WAS NOT REPORTED IF THERE WAS A DELAY IN THE SURGICAL PROCEDURE. IT WAS NOT REPORTED IF A SPARE DEVICE WAS AVAILABLE FOR USE. THIS EVENT DID NOT OCCUR DURING SURGERY. THERE WAS NO PATIENT INVOLVEMENT. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10319592 ↗
  • MalfunctionDec 27, 2019Loose or Intermittent Connection; Loose or Intermittent Connection

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING AN ACL PROCEDURE THE HANDLE AND SHAFT OF THE FEMORAL INTRAFIX SYSTEM 8 MM-8.5 MM X 23 MM, HARD IS GETTING LOOSE. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO PATIENT CONSEQUENCE OR SURGICAL DELAY REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9526231 ↗
  • InjuryAug 20, 2019Break; Peeled/Delaminated; Break; Peeled/Delaminated

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING AN ACL PROCEDURE THE CUSTOMER'S TWO ANTEROMEDIAL FEMORAL AIMERS 5.5MM AND TWO ANTEROMEDIAL FEMORAL AIMERS 6.5MM WERE LEAVING METAL SHAVINGS IN THE PATIENT'S JOINT SPACE. THEY USED A SHAVER TO REMOVE THE METAL SHAVINGS FROM THE PATIENT. THE SALES REP STATED THAT THERE WAS NO DEBRIS LEFT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A FIFTEEN MINUTE SURGICAL DELAY TO THE CASE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICE ARE OLDER DEVICES AND HAVE SEEN HEAVY USE IN THE FIELD. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: No Code Available; Not Applicable

    MAUDE report 8910706 ↗
  • InjuryAug 20, 2019Break; Peeled/Delaminated; Break; Peeled/Delaminated

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING AN ACL PROCEDURE THE CUSTOMER'S TWO ANTEROMEDIAL FEMORAL AIMERS 5.5 MM AND TWO ANTEROMEDIAL FEMORAL AIMERS 6.5 MM WERE LEAVING METAL SHAVINGS IN THE PATIENT'S JOINT SPACE. THEY USED A SHAVER TO REMOVE THE METAL SHAVINGS FROM THE PATIENT. THE SALES REP STATED THAT THERE WAS NO DEBRIS LEFT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A FIFTEEN MINUTE SURGICAL DELAY TO THE CASE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICE ARE OLDER DEVICES AND HAVE SEEN HEAVY USE IN THE FIELD. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: No Code Available; Not Applicable

    MAUDE report 8910649 ↗
  • InjuryJun 6, 2018Break; Break

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING AN ACL PROCEDURE THE CUSTOMER'S ANTEROMEDIAL FEMORAL AIMER CREATED METAL SHAVINGS IN THE PATIENT'S JOINT SPACE. THE SALES REP COULD NOT CONFIRM IF ALL THE METAL SHAVINGS WERE REMOVED FROM THE JOINT SPACE. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH A FIVE MINUTE DELAY TO SWAP OUT THE DEVICE. THE SALES REP WAS NOT PRESENT FOR THE CASE THEREFORE COULD NOT PROVIDE ANY FURTHER INFORMATION. THE DEVICE WILL BE RETURNING FOR EVALUATION.

    Patient problems: Foreign Body In Patient

    MAUDE report 7574618 ↗