Medos International Sàrl · HEALIX ADVANCE Cortical Awl-Tap Package Contains: 1 Cortical Awl-Tap 4.5mm · Class 1

All models of HEALIX ADVANCE (21)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10886705022410), received between Jul 24, 2019 and May 21, 2025 — classified as 9 malfunctions.

The most frequently reported specific device problem is “Dull, Blunt” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Dull, Blunt5
  • Failure to Cut4
  • Degraded2
  • Material Deformation1
  • Unintended Movement1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Not Applicable4
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 21, 2025Degraded; Degraded

    IT WAS REPORTED THAT THE 4.5 NG HEALIX CORTICAL AWL/TAP DEVICE WAS RUSTED AND THE TAP TIP WAS DULL. THE USER SAID THEY OPENED UP A SPARE DEVICE. IT WAS UNKNOWN WHEN THE EVENT OCCURRED. THERE WERE NO REPORTS OF DELAYS TO THE PROCEDURE. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. THE DATE OF EVENT WAS UNKNOWN BUT WAS KNOWN TO HAVE OCCURRED IN 2025. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22060166 ↗
  • MalfunctionOct 17, 2024Unintended Movement; Unintended Movement

    IT WAS REPORTED FROM AUSTRALIA THAT DURING A ROTATOR CUFF REPAIR PROCEDURE, IT WAS DISCOVERED THAT THE 4.5 NG HEALIX CORTICAL AWL/TAP DEVICE WAS WOBBLY. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS IN THE SURGICAL PROCEDURE OR IF A SPARE DEVICE WAS AVAILABLE FOR USE. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20473865 ↗
  • MalfunctionJun 16, 2022Degraded; Degraded

    IT WAS REPORTED BY THE SALES REP THAT DURING A ROTATOR CUFF REPAIR PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE TIP OF THE 4.5 HEALIX ADVANCE CORTICAL AWL-TAP WAS DULL. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14713036 ↗
  • MalfunctionJun 16, 2022Material Deformation; Material Deformation

    IT WAS REPORTED BY THE SALES REP THAT DURING A ROTATOR CUFF REPAIR PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE 4.5 HEALIX ADVANCE CORTICAL AWL-TAP DEVICE WAS BENT. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14713019 ↗
  • MalfunctionOct 8, 2019Dull, Blunt; Dull, Blunt

    IT WAS REPORTED BY THE SALES REPRESENTATIVE THAT THE AWLS IN A HEALIX ADVANCE INSTRUMENT SET (UMHEA05N) ARE VERY BLUNT AND NEED TO BE REPLACED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9166699 ↗
  • MalfunctionJul 26, 2019Dull, Blunt; Failure to Cut; Dull, Blunt; Failure to Cut

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A ROTATOR CUFF REPAIR PROCEDURE IT WAS FOUND THAT THE LASER LINES ON THE CUSTOMER'S 4.5 HEALIX ADVANCE AWL AND TWO 4.5 HEALIX ADVANCE CORTICAL AWL-TAPS ARE FADED. THE SALES REP ALSO STATED THAT THE TAPS ARE DULL. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A SURGICAL DELAY OF TWO MINUTES TO GRAB ANOTHER ONE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICES ARE OLDER DEVICES. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: Not Applicable

    MAUDE report 8832868 ↗
  • MalfunctionJul 26, 2019Dull, Blunt; Failure to Cut; Dull, Blunt; Failure to Cut

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A ROTATOR CUFF REPAIR PROCEDURE IT WAS FOUND THAT THE LASER LINES ON THE CUSTOMER'S 4.5 HEALIX ADVANCE AWL AND TWO 4.5 HEALIX ADVANCE CORTICAL AWL-TAPS ARE FADED. THE SALES REP ALSO STATED THAT THE TAPS ARE DULL. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A SURGICAL DELAY OF TWO MINUTES TO GRAB ANOTHER ONE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICES ARE OLDER DEVICES. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: Not Applicable

    MAUDE report 8832743 ↗
  • MalfunctionJul 24, 2019Dull, Blunt; Failure to Cut; Dull, Blunt; Failure to Cut

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A ROTATOR CUFF REPAIR PROCEDURE IT WAS FOUND THAT THE LASER LINES ON THE CUSTOMER'S 4.5 HEALIX ADVANCE AWL AND TWO 4.5 HEALIX ADVANCE CORTICAL AWL-TAPS ARE FADED. THE SALES REP ALSO STATED THAT THE TAPS ARE DULL. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A SURGICAL DELAY OF TWO MINUTES TO GRAB ANOTHER ONE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICES ARE OLDER DEVICES. THE SALES REP WAS NOT PRESENT FOR THE CASE THEREFORE COULD NOT PROVIDE ANY FURTHER INFORMATION. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: Not Applicable

    MAUDE report 8823423 ↗
  • MalfunctionJul 24, 2019Dull, Blunt; Failure to Cut; Dull, Blunt; Failure to Cut

    IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A ROTATOR CUFF REPAIR PROCEDURE IT WAS FOUND THAT THE LASER LINES ON THE CUSTOMER'S 4.5 HEALIX ADVANCE AWL AND TWO 4.5 HEALIX ADVANCE CORTICAL AWL-TAPS ARE FADED. THE SALES REP ALSO STATED THAT THE TAPS ARE DULL. THE PROCEDURE WAS COMPLETED WITH ANOTHER LIKE DEVICE WITH NO PATIENT HARM BUT THERE WAS A SURGICAL DELAY OF TWO MINUTES TO GRAB ANOTHER ONE. THE SALES REP COULD NOT PROVIDE LOT NUMBERS FOR THE DEVICES BUT STATED THAT THE DEVICES ARE OLDER DEVICES. THE SALES REP WAS NOT PRESENT FOR THE CASE THEREFORE COULD NOT PROVIDE ANY FURTHER INFORMATION. THE DEVICES WILL BE RETURNING FOR EVALUATION.

    Patient problems: Not Applicable

    MAUDE report 8823093 ↗