RIGIDLOOP 232028Recalls & reported problems
Medos International Sàrl · RIGIDLOOP Cannulated Reamer 20-130mm Plus or Minus 0.1mm 4.5mm · Class 1
All models of RIGIDLOOP (16)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886705022755), received between Feb 28, 2022 and Mar 6, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Degraded” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Degraded2
- Break1
- Illegible Information1
- Inaccurate Information1
- Material Deformation1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2026Material Deformation
IT WAS REPORTED THAT THE ACL DRILLPN W/EYE .094X14 DEVICE AND RIGIDLOOP REAMER 4.5MM DEVICE WERE DEFECTIVE; BENT. IT WAS NOT REPORTED IF THE DEVICE WAS USED IN SURGERY. THERE WERE NO REPORTS OF SURGICAL DELAY. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. THE EXACT DATE OF THE EVENT WAS UNKNOWN. HOWEVER, IT WAS REPORTED THAT THE EVENT OCCURRED IN 2026. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24534689 ↗MalfunctionFeb 11, 2025Degraded; Degraded
IT WAS REPORTED THAT WHILE PERFORMING AN ANTERIOR CRUCIATE LIGAMENT TECHNIQUE, DURING THE BROCADE OF THE TIBIA, A DRILL BIT DEVICE OF TIBIA WAS USED WITH THE RESTORE FULL FLUTE REAM DEVICE WHICH WAS INEFFICIENT AND THE ASSISTANT SPECIALIST HAD TO EXERT MORE FORCE TO PERFORM THE TUNNEL AND IN TURN. A LOT OF DELAY OCCURRED DURING THIS STEP, THE STATE OF THE MOTOR AND BATTERY WERE VERIFIED TO RULE OUT FAILURES OF THE POWER EQUIPMENT. SATISFACTORY TO THE ASSESSMENT IN TERMS OF FORCE AND SPEED, THIS BEING RULED OUT AS CAUSAL. THE PROCESS TAKES LONGER THAN USUAL TO CROSS THE METAPHYSIS AND EFFECTIVELY PERFORATE THE ARTICULAR CORTEX OF THE TUNNEL, THE TIP OF THE BUTTONHOLE PIN WAS PROTECTED WITH A CURETTE, HOWEVER, THE FORCE ADMINISTERED TO BE ABLE TO PIERCE THE ARTICULAR CORTEX MUST BE SO MUCH THAT AT THE EXIT OF THE JOINT. IT WAS IMPOSSIBLE TO CONTROL THAT THE DRILL BIT WAS NOT AT THE END OF THE JOINT. THIS IS REPORT 1 OF 2 OF (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21357949 ↗MalfunctionSep 15, 2024Inaccurate Information; Inaccurate Information
THIS IS REPORT 9 OF 10 FOR (B)(4). IT WAS REPORTED FROM CHINA THAT THE LOT NUMBER ON THE LABEL ON THE RIGIDLOOP REAMER 4.5MM DEVICE WAS NOT CONSISTENT WITH THE LOT NUMBER THAT WAS ETCHED ON IT. THIS EVENT DID NOT OCCUR DURING SURGERY. THERE WAS NO PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20220915 ↗MalfunctionMay 20, 2024Degraded; Illegible Information; Degraded; Illegible Information
IT WAS REPORTED BY THE SALES REP IN COLOMBIA THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE ON (B)(6) 2024 THE TENDON HARV CLOSED STRIPPER EA DEVICE AND RIGIDLOOP REAMER 4.5MM DEVICE DRILL DID NOT CUT AND THE LASER MARKS WERE NO LONGER VISIBLE ON THE DRILL AND THE DOCTOR LIKED TO USE THE DRILL TO MEASURE THE DEPTH OF THE FIRST FEMORAL TUNNEL FOR THE PASSAGE OF THE RIGID LOOP PLATE. THERE WERE NO REPORTS OF ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED. THIS IS REPORT 2 OF 2 OF THE SAME EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19352340 ↗MalfunctionJul 26, 2023Use of Device Problem; Use of Device Problem
IT WAS REPORTED BY A HEALTHCARE PROFESSIONAL IN AUSTRALIA THAT THE RIGIDLOOP CANNULATED REAMER 4.5MM DEVICE WAS MISSING FROM THEIR CONSIGNMENT SET. THERE WAS NO PROCEDURE NOR PATIENT INVOLVEMENT REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17398251 ↗MalfunctionFeb 28, 2022Break; Break
IT WAS REPORTED BY THE CUSTOMER IN (B)(6) THAT DURING AN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE RIGIDLOOP REAMER 4.5MM DEVICE BROKE. ALL THE BROKEN FRAGMENTS WERE REMOVED. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13623338 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page