NA 288222Recalls & reported problems
Medos International Sàrl · Latarjet EXPERIENCE Screw Titanium Sterile Screw 28mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10886705026999), received between May 6, 2019 and Jul 3, 2025 — classified as 3 injuries.
The most frequently reported specific device problem is “Failure to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Failure to Advance1
Patient problems
- Impaired Healing2
- No Code Available1
- Not Applicable1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJul 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REPORT 3 OF 4 FOR (B)(4). IT WAS REPORTED THAT THE SURGEON BELIEVED THE LATARJET SYSTEM, WHICH COMPRISED THE LATARJET PROCEDURE KIT DEVICE, STERILE LATARJET SCREW (44MM), STERILE LATARJET SCREW (28MM), AND STERILE TOP HAT DEVICE, LED TO NON-UNIONS IN THE FIXATION OF THE GLENOID BONE. THE SPECIFIC PROCEDURE WAS NOT IDENTIFIED. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS TO THE SURGICAL PROCEDURE OR IF SPARE DEVICES WERE AVAILABLE FOR USE. IT WAS NOT SPECIFIED WHETHER THERE WERE INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. THE EXACT DATE OF THE EVENT WAS UNKNOWN. HOWEVER, IT WAS REPORTED THAT THE EVENT OCCURRED IN 2025. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: Impaired Healing
MAUDE report 22394480 ↗InjuryJul 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REPORT 3 OF 4 FOR (B)(4). IT WAS REPORTED THAT THE SURGEON BELIEVED THE LATARJET SYSTEM, WHICH COMPRISED THE LATARJET PROCEDURE KIT DEVICE, STERILE LATARJET SCREW (44MM), STERILE LATARJET SCREW (28MM), AND STERILE TOP HAT DEVICE, LED TO NON-UNIONS IN THE FIXATION OF THE GLENOID BONE. THE SPECIFIC PROCEDURE WAS NOT IDENTIFIED. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS TO THE SURGICAL PROCEDURE OR IF SPARE DEVICES WERE AVAILABLE FOR USE. IT WAS NOT SPECIFIED WHETHER THERE WERE INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. THE EXACT DATE OF THE EVENT WAS UNKNOWN. HOWEVER, IT WAS REPORTED THAT THE EVENT OCCURRED IN 2025. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.
Patient problems: Impaired Healing
MAUDE report 22393877 ↗InjuryMay 6, 2019Failure to Advance; Failure to Advance
THIS IS REPORT 3 OF 4 FOR THE SAME EVENT. IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A LATARJET PROCEDURE, THE TWO 30MM STERILE LATARJET SCREWS WERE INSERTED AND DID NOT FLUSH TO THE GLENOID AND CORTICAL. THE SALES REP STATED THAT A 28MM STERILE LATARJET SCREW WAS OPENED, BUT ALSO DID NOT FLUSH TO THE GLENOID AND CORTICAL. A 34MM STERILE LATARJET SCREW WAS OPENED AND ALSO DID NOT FLUSH TO THE GLENOID AND CORTICAL. THESE SCREWS DID NOT PROVIDE THE COMPRESSION NECESSARY TO COMPLETE THE CASE AND EACH WAS REMOVED FROM THE PATIENT WITH NO DEBRIS LEFT BEHIND. THE CASE WAS COMPLETED BY SHAVING THE CORTICAL FURTHER AND USING A 32MM SCREW AND A 34MM SCREW, WHICH WAS DIFFERENT FROM THE COMPLAINT SCREW. THERE WAS A SURGICAL DELAY, BUT IT WAS NOT SPECIFIED HOW LONG. THERE WAS NO PATIENT HARM REPORTED. THE SALES REP WAS NOT PRESENT AND COULD NOT PROVIDE ANY ADDITIONAL INFORMATION. THE DEVICES WERE DISCARDED BY THE CUSTOMER. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED AC
Patient problems: No Code Available; Not Applicable
MAUDE report 8582420 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page