HEALIX TI 3 SUTURE ANCHOR w/DYNACORD 222056Recalls & reported problems
Medos International Sàrl · HEALIX TI 3 SUTURE ANCHOR w/DYNACORD Titanium Anchor (1) Blue (1) White/Blue/Green Striped (1) White/Black Striped, Size 2 (5 Metric), DYNACORD Suture, 36" (91 cm) 5.5mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886705029952), received between Feb 25, 2025 and Feb 25, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Unspecified Tissue Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 25, 2025Break; Break
IT WAS REPORTED THAT DURING ROTATOR CUFF REPAIR PROCEDURE, WHILE THE 5.5 HEALIX TI ANCHOR WITH DYNACORD 3-SUT DEVICE WAS INSERTED IT WAS OBSERVED THAT THE SHAFT BROKE, LEAVING THE IMPLANT 50% PROUD OF THE CORTICAL LAYER OF BONE. ACCORDING TO THE REPORTER, THE DOCTOR ATTEMPTED TO REMOVE THE IMPLANT USING THE BROKEN SHAFT AND A SCREW REMOVAL KIT BUT WAS UNABLE. IT WAS REPORTED THAT REMOVAL WAS SUCCESSFUL BY USING A FREER AROUND THE IMPLANT, RESULTING IN BONE LOSS OF THE PATIENT. A DIFFERENT HEALIX TI SIZE WAS USED TO COMPLETE THE REPAIR. THERE WAS A FIFTEEN MINUTE DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Unspecified Tissue Injury
MAUDE report 21456826 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.