Skip to content

VA-LCP 02.111.670SRecalls & reported problems

Synthes GmbH · 2.4/2.7 VA-LCP 2-C DRP STD 6H HD/7H SHAFT/109MM/RT-STER · Class 2 · Implant

All models of VA-LCP (256)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10886982032126), received between Oct 20, 2022 and Nov 4, 2024 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device-Device Incompatibility1

Patient problems

  • Pain2
  • Muscle/Tendon Damage1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS COMPLAINT IS FROM A DATA USE AGREEMENT (DUA). THE DUA SUMMARIZES 55 PATIENTS WHO UNDERWENT WRIST SURGERY BETWEEN 2008 AND 2023 UTILIZING DEPUY SYNTHES LCP DIA-META VOLAR DISTAL RADIUS PLATES (N=20), DEPUY SYNTHES 2.4 MM VA-LCP DORSAL DISTAL RADIUS PLATES (N=20), AND DEPUY SYNTHES 2.4/2.7 MM VA-LCP TWO-COLUMN VOLAR DISTAL RADIUS PLATE (N=15), EXTRA-LONG AT CLEVELAND CLINIC FOUNDATION (CCF). PATIENT IS A 42-YEAR-OLD FEMALE. REASON FOR IMPLANTATION WAS FRACTURE REPAIR. POST OP COMPLICATION INCLUDE RETAINED PAINFUL HARDWARE, RIGHT RADIUS. TREATMENT/INTERVENTION INCLUDE RIGHT RADIUS HARDWARE REMOVAL. IMPLANT(S) INVOLVED: PLATE X1. COMBINATION OF 2.4 & 2.7 SCREWS X 8.

    Patient problems: Pain

    MAUDE report 20599477 ↗
  • MalfunctionSep 12, 2024Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING AN POLYTRAUMA (ACETABULUM, BILATERAL WRISTS, AND TIBIAL NAIL), A FEW PRODUCTS DID NOT WORK. TWO SUPRAPATELLAR HANDLES WERE USED AND UNABLE TO CONNECT THE NAIL. DURING PLACEMENT OF A SACROILIAC SCREW, A LONG EX FIX SLEEVE WAS USED AS A DRILL GUIDE AND THREE WERE BENT. TWO EXTRA LONG VOLAR DISTAL RADIUS PLATES WERE USED AND TWO DISTAL SCREWS DID NOT LOCK IN EACH PLATE. THEY USED A LOCKING TOWER AND SALES REP BELIEVE IT HAD DAMAGED THREADS THAT DAMAGED THE LOCKING MECHANISM INS OF THE PLATE. THEY USED A STANDARD INITIALLY THEN SWITCHED TO NARROW. THERE WAS NO SURGICAL DELAY. NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20202951 ↗
  • InjuryOct 20, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THERE WAS AN INTRA ARTICULAR FRACTURE FIXATION FOR DISTAL RADIUS WITH EXTENSION TO RADIAL DIAPHYSIS. POSTOPERATIVE COMPLICATIONS WERE POLY TRAUMA WITH EXTENSIVE ARTICULAR EXTENSION, EPL RUPTURE, DRUJ INSTABILITY AND CHRONIC PAIN RETURN TO OR 17M S/P INITIAL FIXATION FOR ARTHROSCOPIC SYNOVECTOMY, RIGHT WRIST WITH RADIOCARPAL. THIS REPORT IS FOR ONE (1) 2.4/2.7 VA-LCP 2-C DRP STD 6H HD/7H SHAFT/109MM/RT-STER. THIS IS REPORT 1 OF 11 FOR COMPLAINT (B)(4).

    Patient problems: Muscle/Tendon Damage; Pain

    MAUDE report 15641512 ↗

Other Plate, fixation, bone devices

All Plate, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page