VA-LCP 02.111.731SRecalls & reported problems
Synthes GmbH · 2.4MM VA-LCP 2-CLMN VLR DSTL RAD PL 7H HD/3H SHAFT/LT-STER · Class 2 · Implant
All models of VA-LCP (256)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982032324), received between Jun 24, 2021 and Jun 24, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K083694); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility2
- Material Twisted/Bent2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 24, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, ON AN UNKNOWN PROCEDURE, THE (1) DEPTH GAUGE FOR SMALL SCREWS, (2) PROTECTION SLEEVE/ 11/8, (2) DRILL SLEEVE / 4.2MM, (2) SCREWDRIVER SHAFT SDDRIVE 165MM, (6) 2.8MM FIXED ANGLE DRILL GUIDE, (3) 7.3MM CANNULATED SCREW 32MM THREAD/140MM, (1) SCR RACK 6.5 TI&SS CANN SCRS-16/32 THRDS, (1) LCKNG ATTACH WASHER TRAY RFN-ADVANCED, (2) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/RT-S, AND (2) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/LT-S HAVE AN UNKNOWN ALLEGATION. FIXED ANGLE GUIDES DON'T FIT INTO VA LOCKING HOLES, SCREWS WERE STRIPPED IN PROCESS. THERE WAS NO KNOWN HOSPITAL OR PATIENT INVOLVEMENT. THIS COMPLAINT INVOLVES TWENTY-TWO (22) DEVICES. THIS REPORT IS FOR (1) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/RT-S. THIS REPORT IS 13 OF 13 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12063571 ↗MalfunctionJun 24, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, ON AN UNKNOWN PROCEDURE, THE (1) DEPTH GAUGE FOR SMALL SCREWS, (2) PROTECTION SLEEVE/ 11/8, (2) DRILL SLEEVE / 4.2MM, (2) SCREWDRIVER SHAFT SDDRIVE 165MM, (6) 2.8MM FIXED ANGLE DRILL GUIDE, (3) 7.3MM CANNULATED SCREW 32MM THREAD/140MM, (1) SCR RACK 6.5 TI&SS CANN SCRS-16/32 THRDS, (1) LCKNG ATTACH WASHER TRAY RFN-ADVANCED, (2) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/RT-S, AND (2) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/LT-S HAVE AN UNKNOWN ALLEGATION. FIXED ANGLE GUIDES DON'T FIT INTO VA LOCKING HOLES, SCREWS WERE STRIPPED IN PROCESS. THERE WAS NO KNOWN HOSPITAL OR PATIENT INVOLVEMENT. THIS COMPLAINT INVOLVES TWENTY-TWO (22) DEVICES. THIS REPORT IS FOR (1) 2.4 VA 2-CLMN VLR DRP 7H HD/3H SFT/RT-S. THIS REPORT IS 4 OF 13 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12063355 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K083694. One submission often covers many models, so check the product and lot details in each record.
- Z-2087-2013 · Jul 30, 2013 · TerminatedSynthes 2.4 VA-LCP 2 CLMN VLR DSTL Radius PL 7H HD/3H Shaft/Right Product Usage: Intended for fixation of complex intra-and extra-articular fractures and osteotomies of the dista
- Z-2057-2013 · May 31, 2013 · TerminatedSynthes 2.4mm VA-LCP Two Column Volar Distal Radius Plate and Torque limiting attachment, 1.2Nm Synthes VA-LCP Distal Radius System is intended for fixation of complex intra- and
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page