LCP 02.112.018Recalls & reported problems
Synthes GmbH · 3.5MM LCP SUP ANT CLAVICLE PL W/LAT EXTN 7H/RT/123MM · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982032713), received between Jul 28, 2020 and Aug 11, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Material Twisted/Bent1
- Scratched Material1
Patient problems
- No Consequences Or Impact To Patient1
- Pain1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryAug 11, 2021Break; Break
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT PATIENT WILL UNDERGO REVISION SURGERY DUE TO A BROKEN PLATE. THE DOCTOR REPORTS THAT THE CLAVICLE PLATE PLACED ON THE PATIENT HAS BROKEN DUE TO FATIGUE, FOR WHICH THEY ARE GOING TO REMOVE THE IMPLANT AND PLACE ANOTHER ONE. PATIENT ALSO EXPERIENCED PAIN. THIS REPORT IS FOR A 3.5MM LOCKING COMPRESSION PLATE (LCP) SUP ANT CLAVICLE PLATE. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: Pain
MAUDE report 12306816 ↗MalfunctionJul 28, 2020Material Twisted/Bent; Scratched Material; Material Twisted/Bent; Scratched Material
IT WAS REPORTED THAT DURING A ROUTINE INCOMING INSPECTION OF A LOANER SET AT FSL UPS (B)(4) SITE ON AN UNKNOWN DATE, THE LOCKING COMPRESSION PLATE (LCP) SUPERIOR ANTERIOR CLAVICLE PLATE WAS OBSERVED DAMAGED WITH A SCRATCHED PLATE. THERE WERE NO PATIENT AND SURGICAL INVOLVEMENT. THIS COMPLAINT INVOLVES 1 DEVICE. THIS REPORT IS FOR (1) 3.5MM LCP SUP ANT CLAVICLE PL W/LAT EXTN 7H/RT/123MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10335654 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page